Message ID | 1419216816-13171-1-git-send-email-quwenruo@cn.fujitsu.com (mailing list archive) |
---|---|
State | Accepted |
Headers | show |
On 2014/12/22 11:53, Qu Wenruo wrote: > The original check_inode_recs() will return -1 if found any error in a > inode_record. This is OK for original design since there is almost > nothing can repair at that time. > > However more and more error from nlink mismatch to missing inode item > can be repaired in try_repair_inode(), check_inode_recs() should not > increase the error count if the inode can be repair. > > With this patch, repair function for leaf-corruption will not return > error if all corruption inode can be recovered. > > Signed-off-by: Qu Wenruo <quwenruo@cn.fujitsu.com> Reviewed-by: Satoru Takeuchi <takeuchi_satoru@jp.fujitsu.com> Thanks, Satoru > --- > cmds-check.c | 5 +++-- > 1 file changed, 3 insertions(+), 2 deletions(-) > > diff --git a/cmds-check.c b/cmds-check.c > index 3e7a4eb..aa47984 100644 > --- a/cmds-check.c > +++ b/cmds-check.c > @@ -2302,7 +2302,7 @@ static int check_inode_recs(struct btrfs_root *root, > struct inode_record *rec; > struct inode_backref *backref; > int stage = 0; > - int ret; > + int ret = 0; > int err = 0; > u64 error = 0; > u64 root_dirid = btrfs_root_dirid(&root->root_item); > @@ -2452,7 +2452,8 @@ static int check_inode_recs(struct btrfs_root *root, > ret = 0; > } > > - error++; > + if (!(repair && ret == 0)) > + error++; > print_inode_error(root, rec); > list_for_each_entry(backref, &rec->backrefs, list) { > if (!backref->found_dir_item) > -- To unsubscribe from this list: send the line "unsubscribe linux-btrfs" in the body of a message to majordomo@vger.kernel.org More majordomo info at http://vger.kernel.org/majordomo-info.html
diff --git a/cmds-check.c b/cmds-check.c index 3e7a4eb..aa47984 100644 --- a/cmds-check.c +++ b/cmds-check.c @@ -2302,7 +2302,7 @@ static int check_inode_recs(struct btrfs_root *root, struct inode_record *rec; struct inode_backref *backref; int stage = 0; - int ret; + int ret = 0; int err = 0; u64 error = 0; u64 root_dirid = btrfs_root_dirid(&root->root_item); @@ -2452,7 +2452,8 @@ static int check_inode_recs(struct btrfs_root *root, ret = 0; } - error++; + if (!(repair && ret == 0)) + error++; print_inode_error(root, rec); list_for_each_entry(backref, &rec->backrefs, list) { if (!backref->found_dir_item)
The original check_inode_recs() will return -1 if found any error in a inode_record. This is OK for original design since there is almost nothing can repair at that time. However more and more error from nlink mismatch to missing inode item can be repaired in try_repair_inode(), check_inode_recs() should not increase the error count if the inode can be repair. With this patch, repair function for leaf-corruption will not return error if all corruption inode can be recovered. Signed-off-by: Qu Wenruo <quwenruo@cn.fujitsu.com> --- cmds-check.c | 5 +++-- 1 file changed, 3 insertions(+), 2 deletions(-)