Message ID | 20171120110125.12267-1-horms+renesas@verge.net.au (mailing list archive) |
---|---|
State | New, archived |
Headers | show |
Hi Simon, On Mon, Nov 20, 2017 at 12:01 PM, Simon Horman <horms+renesas@verge.net.au> wrote: > Move pmu_a5[73], timer and thermal-zones nodes from soc node to root node. > The nodes that have been moved do not have any register properties and thus > shouldn't be placed on the bus. > > This problem is flagged by the compiler as follows: > $ make > ... > DTC arch/arm64/boot/dts/renesas/r8a7795-salvator-x.dtb > arch/arm64/boot/dts/renesas/r8a7795-salvator-x.dtb: Warning (simple_bus_reg): Node /soc/pmu_a57 missing or empty reg/ranges property > arch/arm64/boot/dts/renesas/r8a7795-salvator-x.dtb: Warning (simple_bus_reg): Node /soc/pmu_a53 missing or empty reg/ranges property > arch/arm64/boot/dts/renesas/r8a7795-salvator-x.dtb: Warning (simple_bus_reg): Node /soc/timer missing or empty reg/ranges property > arch/arm64/boot/dts/renesas/r8a7795-salvator-x.dtb: Warning (simple_bus_reg): Node /soc/thermal-zones missing or empty reg/ranges property [...] Thanks for your patch! > Signed-off-by: Simon Horman <horms+renesas@verge.net.au> Reviewed-by: Geert Uytterhoeven <geert+renesas@glider.be> > --- a/arch/arm64/boot/dts/renesas/r8a7795.dtsi > +++ b/arch/arm64/boot/dts/renesas/r8a7795.dtsi > @@ -126,6 +126,86 @@ The node above is called "cpus". > }; > }; > > + pmu_a57 { > + }; > + > + pmu_a53 { > + }; > + > + timer { > + }; > + > + thermal-zones { > + }; > + > extal_clk: extal { > compatible = "fixed-clock"; > #clock-cells = <0>; Any sorting rules (alphabetically?) for nodes at the root level? Gr{oetje,eeting}s, Geert -- Geert Uytterhoeven -- There's lots of Linux beyond ia32 -- geert@linux-m68k.org In personal conversations with technical people, I call myself a hacker. But when I'm talking to journalists I just say "programmer" or something like that. -- Linus Torvalds
On Thu, Nov 23, 2017 at 10:27:55AM +0100, Geert Uytterhoeven wrote: > Hi Simon, > > On Mon, Nov 20, 2017 at 12:01 PM, Simon Horman > <horms+renesas@verge.net.au> wrote: > > Move pmu_a5[73], timer and thermal-zones nodes from soc node to root node. > > The nodes that have been moved do not have any register properties and thus > > shouldn't be placed on the bus. > > > > This problem is flagged by the compiler as follows: > > $ make > > ... > > DTC arch/arm64/boot/dts/renesas/r8a7795-salvator-x.dtb > > arch/arm64/boot/dts/renesas/r8a7795-salvator-x.dtb: Warning (simple_bus_reg): Node /soc/pmu_a57 missing or empty reg/ranges property > > arch/arm64/boot/dts/renesas/r8a7795-salvator-x.dtb: Warning (simple_bus_reg): Node /soc/pmu_a53 missing or empty reg/ranges property > > arch/arm64/boot/dts/renesas/r8a7795-salvator-x.dtb: Warning (simple_bus_reg): Node /soc/timer missing or empty reg/ranges property > > arch/arm64/boot/dts/renesas/r8a7795-salvator-x.dtb: Warning (simple_bus_reg): Node /soc/thermal-zones missing or empty reg/ranges property > > [...] > > Thanks for your patch! > > > Signed-off-by: Simon Horman <horms+renesas@verge.net.au> > > Reviewed-by: Geert Uytterhoeven <geert+renesas@glider.be> > > > --- a/arch/arm64/boot/dts/renesas/r8a7795.dtsi > > +++ b/arch/arm64/boot/dts/renesas/r8a7795.dtsi > > @@ -126,6 +126,86 @@ > > The node above is called "cpus". > > > }; > > }; > > > > + pmu_a57 { > > > + }; > > + > > + pmu_a53 { > > > + }; > > + > > + timer { > > > + }; > > + > > + thermal-zones { > > > + }; > > + > > extal_clk: extal { > > compatible = "fixed-clock"; > > #clock-cells = <0>; > > Any sorting rules (alphabetically?) for nodes at the root level? Now would be a good time to decide on an alternate on an order as I plan to submit similar patches for several other SoCs. I took used order they were already present (with other nodes) in the cpu node. They appear to be sorted alphabetically. Should I keep that sort order relative to existing nodes present in the root node?
Hi Simon, On Thu, Nov 23, 2017 at 10:46 AM, Simon Horman <horms@verge.net.au> wrote: > On Thu, Nov 23, 2017 at 10:27:55AM +0100, Geert Uytterhoeven wrote: >> On Mon, Nov 20, 2017 at 12:01 PM, Simon Horman >> <horms+renesas@verge.net.au> wrote: >> > --- a/arch/arm64/boot/dts/renesas/r8a7795.dtsi >> > +++ b/arch/arm64/boot/dts/renesas/r8a7795.dtsi >> > @@ -126,6 +126,86 @@ >> >> The node above is called "cpus". >> >> > }; >> > }; >> > >> > + pmu_a57 { >> >> > + }; >> > + >> > + pmu_a53 { >> >> > + }; >> > + >> > + timer { >> >> > + }; >> > + >> > + thermal-zones { >> >> > + }; >> > + >> > extal_clk: extal { >> > compatible = "fixed-clock"; >> > #clock-cells = <0>; >> >> Any sorting rules (alphabetically?) for nodes at the root level? > > Now would be a good time to decide on an alternate on an order as > I plan to submit similar patches for several other SoCs. > > I took used order they were already present (with other nodes) in the > cpu node. They appear to be sorted alphabetically. Should I keep that > sort order relative to existing nodes present in the root node? I think you should. Gr{oetje,eeting}s, Geert -- Geert Uytterhoeven -- There's lots of Linux beyond ia32 -- geert@linux-m68k.org In personal conversations with technical people, I call myself a hacker. But when I'm talking to journalists I just say "programmer" or something like that. -- Linus Torvalds
diff --git a/arch/arm64/boot/dts/renesas/r8a7795.dtsi b/arch/arm64/boot/dts/renesas/r8a7795.dtsi index a438d58f1b50..67ef06416bc4 100644 --- a/arch/arm64/boot/dts/renesas/r8a7795.dtsi +++ b/arch/arm64/boot/dts/renesas/r8a7795.dtsi @@ -126,6 +126,86 @@ }; }; + pmu_a57 { + compatible = "arm,cortex-a57-pmu"; + interrupts = <GIC_SPI 72 IRQ_TYPE_LEVEL_HIGH>, + <GIC_SPI 73 IRQ_TYPE_LEVEL_HIGH>, + <GIC_SPI 74 IRQ_TYPE_LEVEL_HIGH>, + <GIC_SPI 75 IRQ_TYPE_LEVEL_HIGH>; + interrupt-affinity = <&a57_0>, + <&a57_1>, + <&a57_2>, + <&a57_3>; + }; + + pmu_a53 { + compatible = "arm,cortex-a53-pmu"; + interrupts = <GIC_SPI 84 IRQ_TYPE_LEVEL_HIGH>, + <GIC_SPI 85 IRQ_TYPE_LEVEL_HIGH>, + <GIC_SPI 86 IRQ_TYPE_LEVEL_HIGH>, + <GIC_SPI 87 IRQ_TYPE_LEVEL_HIGH>; + interrupt-affinity = <&a53_0>, + <&a53_1>, + <&a53_2>, + <&a53_3>; + }; + + timer { + compatible = "arm,armv8-timer"; + interrupts = <GIC_PPI 13 + (GIC_CPU_MASK_SIMPLE(8) | IRQ_TYPE_LEVEL_LOW)>, + <GIC_PPI 14 + (GIC_CPU_MASK_SIMPLE(8) | IRQ_TYPE_LEVEL_LOW)>, + <GIC_PPI 11 + (GIC_CPU_MASK_SIMPLE(8) | IRQ_TYPE_LEVEL_LOW)>, + <GIC_PPI 10 + (GIC_CPU_MASK_SIMPLE(8) | IRQ_TYPE_LEVEL_LOW)>; + }; + + thermal-zones { + sensor_thermal1: sensor-thermal1 { + polling-delay-passive = <250>; + polling-delay = <1000>; + thermal-sensors = <&tsc 0>; + + trips { + sensor1_crit: sensor1-crit { + temperature = <120000>; + hysteresis = <2000>; + type = "critical"; + }; + }; + }; + + sensor_thermal2: sensor-thermal2 { + polling-delay-passive = <250>; + polling-delay = <1000>; + thermal-sensors = <&tsc 1>; + + trips { + sensor2_crit: sensor2-crit { + temperature = <120000>; + hysteresis = <2000>; + type = "critical"; + }; + }; + }; + + sensor_thermal3: sensor-thermal3 { + polling-delay-passive = <250>; + polling-delay = <1000>; + thermal-sensors = <&tsc 2>; + + trips { + sensor3_crit: sensor3-crit { + temperature = <120000>; + hysteresis = <2000>; + type = "critical"; + }; + }; + }; + }; + extal_clk: extal { compatible = "fixed-clock"; #clock-cells = <0>; @@ -338,42 +418,6 @@ resets = <&cpg 905>; }; - pmu_a57 { - compatible = "arm,cortex-a57-pmu"; - interrupts = <GIC_SPI 72 IRQ_TYPE_LEVEL_HIGH>, - <GIC_SPI 73 IRQ_TYPE_LEVEL_HIGH>, - <GIC_SPI 74 IRQ_TYPE_LEVEL_HIGH>, - <GIC_SPI 75 IRQ_TYPE_LEVEL_HIGH>; - interrupt-affinity = <&a57_0>, - <&a57_1>, - <&a57_2>, - <&a57_3>; - }; - - pmu_a53 { - compatible = "arm,cortex-a53-pmu"; - interrupts = <GIC_SPI 84 IRQ_TYPE_LEVEL_HIGH>, - <GIC_SPI 85 IRQ_TYPE_LEVEL_HIGH>, - <GIC_SPI 86 IRQ_TYPE_LEVEL_HIGH>, - <GIC_SPI 87 IRQ_TYPE_LEVEL_HIGH>; - interrupt-affinity = <&a53_0>, - <&a53_1>, - <&a53_2>, - <&a53_3>; - }; - - timer { - compatible = "arm,armv8-timer"; - interrupts = <GIC_PPI 13 - (GIC_CPU_MASK_SIMPLE(8) | IRQ_TYPE_LEVEL_LOW)>, - <GIC_PPI 14 - (GIC_CPU_MASK_SIMPLE(8) | IRQ_TYPE_LEVEL_LOW)>, - <GIC_PPI 11 - (GIC_CPU_MASK_SIMPLE(8) | IRQ_TYPE_LEVEL_LOW)>, - <GIC_PPI 10 - (GIC_CPU_MASK_SIMPLE(8) | IRQ_TYPE_LEVEL_LOW)>; - }; - cpg: clock-controller@e6150000 { compatible = "renesas,r8a7795-cpg-mssr"; reg = <0 0xe6150000 0 0x1000>; @@ -2331,49 +2375,5 @@ #thermal-sensor-cells = <1>; status = "okay"; }; - - thermal-zones { - sensor_thermal1: sensor-thermal1 { - polling-delay-passive = <250>; - polling-delay = <1000>; - thermal-sensors = <&tsc 0>; - - trips { - sensor1_crit: sensor1-crit { - temperature = <120000>; - hysteresis = <2000>; - type = "critical"; - }; - }; - }; - - sensor_thermal2: sensor-thermal2 { - polling-delay-passive = <250>; - polling-delay = <1000>; - thermal-sensors = <&tsc 1>; - - trips { - sensor2_crit: sensor2-crit { - temperature = <120000>; - hysteresis = <2000>; - type = "critical"; - }; - }; - }; - - sensor_thermal3: sensor-thermal3 { - polling-delay-passive = <250>; - polling-delay = <1000>; - thermal-sensors = <&tsc 2>; - - trips { - sensor3_crit: sensor3-crit { - temperature = <120000>; - hysteresis = <2000>; - type = "critical"; - }; - }; - }; - }; }; };
Move pmu_a5[73], timer and thermal-zones nodes from soc node to root node. The nodes that have been moved do not have any register properties and thus shouldn't be placed on the bus. This problem is flagged by the compiler as follows: $ make ... DTC arch/arm64/boot/dts/renesas/r8a7795-salvator-x.dtb arch/arm64/boot/dts/renesas/r8a7795-salvator-x.dtb: Warning (simple_bus_reg): Node /soc/pmu_a57 missing or empty reg/ranges property arch/arm64/boot/dts/renesas/r8a7795-salvator-x.dtb: Warning (simple_bus_reg): Node /soc/pmu_a53 missing or empty reg/ranges property arch/arm64/boot/dts/renesas/r8a7795-salvator-x.dtb: Warning (simple_bus_reg): Node /soc/timer missing or empty reg/ranges property arch/arm64/boot/dts/renesas/r8a7795-salvator-x.dtb: Warning (simple_bus_reg): Node /soc/thermal-zones missing or empty reg/ranges property DTC arch/arm64/boot/dts/renesas/r8a7795-h3ulcb.dtb arch/arm64/boot/dts/renesas/r8a7795-h3ulcb.dtb: Warning (simple_bus_reg): Node /soc/pmu_a57 missing or empty reg/ranges property arch/arm64/boot/dts/renesas/r8a7795-h3ulcb.dtb: Warning (simple_bus_reg): Node /soc/pmu_a53 missing or empty reg/ranges property arch/arm64/boot/dts/renesas/r8a7795-h3ulcb.dtb: Warning (simple_bus_reg): Node /soc/timer missing or empty reg/ranges property arch/arm64/boot/dts/renesas/r8a7795-h3ulcb.dtb: Warning (simple_bus_reg): Node /soc/thermal-zones missing or empty reg/ranges property DTC arch/arm64/boot/dts/renesas/r8a7795-h3ulcb-kf.dtb arch/arm64/boot/dts/renesas/r8a7795-h3ulcb-kf.dtb: Warning (simple_bus_reg): Node /soc/pmu_a57 missing or empty reg/ranges property arch/arm64/boot/dts/renesas/r8a7795-h3ulcb-kf.dtb: Warning (simple_bus_reg): Node /soc/pmu_a53 missing or empty reg/ranges property arch/arm64/boot/dts/renesas/r8a7795-h3ulcb-kf.dtb: Warning (simple_bus_reg): Node /soc/timer missing or empty reg/ranges property arch/arm64/boot/dts/renesas/r8a7795-h3ulcb-kf.dtb: Warning (simple_bus_reg): Node /soc/thermal-zones missing or empty reg/ranges property DTC arch/arm64/boot/dts/renesas/r8a7795-salvator-xs.dtb arch/arm64/boot/dts/renesas/r8a7795-salvator-xs.dtb: Warning (simple_bus_reg): Node /soc/pmu_a57 missing or empty reg/ranges property arch/arm64/boot/dts/renesas/r8a7795-salvator-xs.dtb: Warning (simple_bus_reg): Node /soc/pmu_a53 missing or empty reg/ranges property arch/arm64/boot/dts/renesas/r8a7795-salvator-xs.dtb: Warning (simple_bus_reg): Node /soc/timer missing or empty reg/ranges property arch/arm64/boot/dts/renesas/r8a7795-salvator-xs.dtb: Warning (simple_bus_reg): Node /soc/thermal-zones missing or empty reg/ranges property DTC arch/arm64/boot/dts/renesas/r8a7795-es1-salvator-x.dtb arch/arm64/boot/dts/renesas/r8a7795-es1-salvator-x.dtb: Warning (simple_bus_reg): Node /soc/pmu_a57 missing or empty reg/ranges property arch/arm64/boot/dts/renesas/r8a7795-es1-salvator-x.dtb: Warning (simple_bus_reg): Node /soc/pmu_a53 missing or empty reg/ranges property arch/arm64/boot/dts/renesas/r8a7795-es1-salvator-x.dtb: Warning (simple_bus_reg): Node /soc/timer missing or empty reg/ranges property arch/arm64/boot/dts/renesas/r8a7795-es1-salvator-x.dtb: Warning (simple_bus_reg): Node /soc/thermal-zones missing or empty reg/ranges property DTC arch/arm64/boot/dts/renesas/r8a7795-es1-h3ulcb.dtb arch/arm64/boot/dts/renesas/r8a7795-es1-h3ulcb.dtb: Warning (simple_bus_reg): Node /soc/pmu_a57 missing or empty reg/ranges property arch/arm64/boot/dts/renesas/r8a7795-es1-h3ulcb.dtb: Warning (simple_bus_reg): Node /soc/pmu_a53 missing or empty reg/ranges property arch/arm64/boot/dts/renesas/r8a7795-es1-h3ulcb.dtb: Warning (simple_bus_reg): Node /soc/timer missing or empty reg/ranges property arch/arm64/boot/dts/renesas/r8a7795-es1-h3ulcb.dtb: Warning (simple_bus_reg): Node /soc/thermal-zones missing or empty reg/ranges property DTC arch/arm64/boot/dts/renesas/r8a7795-es1-h3ulcb-kf.dtb arch/arm64/boot/dts/renesas/r8a7795-es1-h3ulcb-kf.dtb: Warning (simple_bus_reg): Node /soc/pmu_a57 missing or empty reg/ranges property arch/arm64/boot/dts/renesas/r8a7795-es1-h3ulcb-kf.dtb: Warning (simple_bus_reg): Node /soc/pmu_a53 missing or empty reg/ranges property arch/arm64/boot/dts/renesas/r8a7795-es1-h3ulcb-kf.dtb: Warning (simple_bus_reg): Node /soc/timer missing or empty reg/ranges property arch/arm64/boot/dts/renesas/r8a7795-es1-h3ulcb-kf.dtb: Warning (simple_bus_reg): Node /soc/thermal-zones missing or empty reg/ranges property Signed-off-by: Simon Horman <horms+renesas@verge.net.au> --- Based on renesas-devel-20171120-v4.14 If acceptable I plan to create patches to fix this problem in the DT of other Renesas ARM and arm64 based SoCs. --- arch/arm64/boot/dts/renesas/r8a7795.dtsi | 160 +++++++++++++++---------------- 1 file changed, 80 insertions(+), 80 deletions(-)