@@ -62,3 +62,18 @@ bus and shunt voltage conversion times multiplied by the averaging rate. We
don't touch the conversion times and only modify the number of averages. The
lower limit of the update_interval is 2 ms, the upper limit is 2253 ms.
The actual programmed interval may vary from the desired value.
+
+General sysfs entries
+-------------
+
+in0_input Shunt voltage(mV) channel
+in1_input Bus voltage(mV) channel
+curr1_input Current(mA) measurement channel
+power1_input Power(uW) measurement channel
+shunt_resistor Shunt resistance(uOhm) channel
+
+Sysfs entries for ina226, ina230 and ina231 only
+-------------
+
+update_interval data conversion time; affects number of samples used
+ to average results for shunt and bus voltages.
There are a few sysfs entries being exposed to user space by the ina2xx hwmon driver while not getting explicitly documented. So this patch just adds a description section for them. Signed-off-by: Nicolin Chen <nicoleotsuka@gmail.com> --- Documentation/hwmon/ina2xx | 15 +++++++++++++++ 1 file changed, 15 insertions(+)