Series | [v2] HID: wacom: Correct distance scale for 2nd-gen Intuos devices | expand |
On Wed, 7 Aug 2019, Gerecke, Jason wrote: > From: Jason Gerecke <jason.gerecke@wacom.com> > > Distance values reported by 2nd-gen Intuos tablets are on an inverted > scale (0 == far, 63 == near). We need to change them over to a normal > scale before reporting to userspace or else userspace drivers and > applications can get confused. > > Ref: https://github.com/linuxwacom/input-wacom/issues/98 > Fixes: eda01dab53 ("HID: wacom: Add four new Intuos devices") > Signed-off-by: Jason Gerecke <jason.gerecke@wacom.com> > Cc: <stable@vger.kernel.org> # v4.4+ Applied to for-5.3/upstream-fixes. Thanks,
diff --git a/drivers/hid/wacom_wac.c b/drivers/hid/wacom_wac.c index 7a8ddc999a8e..8e5063492242 100644 --- a/drivers/hid/wacom_wac.c +++ b/drivers/hid/wacom_wac.c @@ -846,6 +846,8 @@ static int wacom_intuos_general(struct wacom_wac *wacom) y >>= 1; distance >>= 1; } + if (features->type == INTUOSHT2) + distance = features->distance_max - distance; input_report_abs(input, ABS_X, x); input_report_abs(input, ABS_Y, y); input_report_abs(input, ABS_DISTANCE, distance);