diff mbox series

[v2] platform/x86: pmc_atom: Add Siemens SIMATIC IPC227E to critclk_systems DMI table

Message ID c090302a-da38-5764-2a84-399ed6b333f5@siemens.com (mailing list archive)
State Accepted, archived
Delegated to: Andy Shevchenko
Headers show
Series [v2] platform/x86: pmc_atom: Add Siemens SIMATIC IPC227E to critclk_systems DMI table | expand

Commit Message

Jan Kiszka Sept. 4, 2019, 6:42 a.m. UTC
From: Jan Kiszka <jan.kiszka@siemens.com>

The SIMATIC IPC227E uses the PMC clock for on-board components and gets
stuck during boot if the clock is disabled. Therefore, add this device
to the critical systems list.

Fixes: 648e921888ad ("clk: x86: Stop marking clocks as CLK_IS_CRITICAL")
Signed-off-by: Jan Kiszka <jan.kiszka@siemens.com>
---

Changes in v2:
 - fixed cut-off subject line (local tooling bug...)

Should go into stable as well, down to 4.19.

 drivers/platform/x86/pmc_atom.c | 7 +++++++
 1 file changed, 7 insertions(+)

Comments

Jan Kiszka Nov. 4, 2019, 4:20 p.m. UTC | #1
On 04.09.19 08:42, Jan Kiszka wrote:
> From: Jan Kiszka <jan.kiszka@siemens.com>
> 
> The SIMATIC IPC227E uses the PMC clock for on-board components and gets
> stuck during boot if the clock is disabled. Therefore, add this device
> to the critical systems list.
> 
> Fixes: 648e921888ad ("clk: x86: Stop marking clocks as CLK_IS_CRITICAL")
> Signed-off-by: Jan Kiszka <jan.kiszka@siemens.com>
> ---
> 
> Changes in v2:
>  - fixed cut-off subject line (local tooling bug...)
> 
> Should go into stable as well, down to 4.19.

This one is in 5.4-rc now (as ad0d315b4d4e). Is it also queued somewhere
for stable kernels? IIRC, it's generally the privilege of the subsystem
maintainer to propose formally to stable.

I've received reports from users down at 4.14 with the need for it (4.9
is unaffected). And the same applies to f110d252ae79 ("platform/x86:
pmc_atom: Add Siemens SIMATIC IPC277E to critclk_systems DMI table").

TIA!
Jan

> 
>  drivers/platform/x86/pmc_atom.c | 7 +++++++
>  1 file changed, 7 insertions(+)
> 
> diff --git a/drivers/platform/x86/pmc_atom.c b/drivers/platform/x86/pmc_atom.c
> index aa53648a2214..9aca5e7ce6d0 100644
> --- a/drivers/platform/x86/pmc_atom.c
> +++ b/drivers/platform/x86/pmc_atom.c
> @@ -415,6 +415,13 @@ static const struct dmi_system_id critclk_systems[] = {
>  			DMI_MATCH(DMI_BOARD_NAME, "CB6363"),
>  		},
>  	},
> +	{
> +		.ident = "SIMATIC IPC227E",
> +		.matches = {
> +			DMI_MATCH(DMI_SYS_VENDOR, "SIEMENS AG"),
> +			DMI_MATCH(DMI_PRODUCT_VERSION, "6ES7647-8B"),
> +		},
> +	},
>  	{ /*sentinel*/ }
>  };
>  
>
Andy Shevchenko Nov. 7, 2019, 5:06 p.m. UTC | #2
On Mon, Nov 4, 2019 at 6:21 PM Jan Kiszka <jan.kiszka@siemens.com> wrote:
>
> On 04.09.19 08:42, Jan Kiszka wrote:
> > From: Jan Kiszka <jan.kiszka@siemens.com>
> >
> > The SIMATIC IPC227E uses the PMC clock for on-board components and gets
> > stuck during boot if the clock is disabled. Therefore, add this device
> > to the critical systems list.
> >
> > Fixes: 648e921888ad ("clk: x86: Stop marking clocks as CLK_IS_CRITICAL")
> > Signed-off-by: Jan Kiszka <jan.kiszka@siemens.com>
> > ---
> >
> > Changes in v2:
> >  - fixed cut-off subject line (local tooling bug...)
> >
> > Should go into stable as well, down to 4.19.
>
> This one is in 5.4-rc now (as ad0d315b4d4e). Is it also queued somewhere
> for stable kernels? IIRC, it's generally the privilege of the subsystem
> maintainer to propose formally to stable.

Anybody can resend for stable putting maintainer to Cc as long as the
original commit is in upstream.

Nevertheless, I just resend it.

> I've received reports from users down at 4.14 with the need for it (4.9
> is unaffected). And the same applies to f110d252ae79 ("platform/x86:
> pmc_atom: Add Siemens SIMATIC IPC277E to critclk_systems DMI table").
diff mbox series

Patch

diff --git a/drivers/platform/x86/pmc_atom.c b/drivers/platform/x86/pmc_atom.c
index aa53648a2214..9aca5e7ce6d0 100644
--- a/drivers/platform/x86/pmc_atom.c
+++ b/drivers/platform/x86/pmc_atom.c
@@ -415,6 +415,13 @@  static const struct dmi_system_id critclk_systems[] = {
 			DMI_MATCH(DMI_BOARD_NAME, "CB6363"),
 		},
 	},
+	{
+		.ident = "SIMATIC IPC227E",
+		.matches = {
+			DMI_MATCH(DMI_SYS_VENDOR, "SIEMENS AG"),
+			DMI_MATCH(DMI_PRODUCT_VERSION, "6ES7647-8B"),
+		},
+	},
 	{ /*sentinel*/ }
 };