diff mbox series

[10/10] dt-bindings: power: supply: Cleanup charger-manager bindings

Message ID BN6PR04MB0660E57423994D19C84370A3A3BC0@BN6PR04MB0660.namprd04.prod.outlook.com (mailing list archive)
State Not Applicable, archived
Headers show
Series power: supply: Charger-manager improvements | expand

Commit Message

Jonathan Bakker May 14, 2020, 11:04 p.m. UTC
The bindings for charger-manager were very unclear and didn't
specify allowable values in many cases.  Clean these up to show
what each value does and make sure all properties are documented
here rather than using wildcards.

Signed-off-by: Jonathan Bakker <xc-racer2@live.ca>
---
 .../bindings/power/supply/charger-manager.txt | 30 ++++++++++++-------
 1 file changed, 20 insertions(+), 10 deletions(-)

Comments

Rob Herring May 28, 2020, 5:54 p.m. UTC | #1
On Thu, May 14, 2020 at 04:04:35PM -0700, Jonathan Bakker wrote:
> The bindings for charger-manager were very unclear and didn't
> specify allowable values in many cases.  Clean these up to show
> what each value does and make sure all properties are documented
> here rather than using wildcards.
> 
> Signed-off-by: Jonathan Bakker <xc-racer2@live.ca>
> ---
>  .../bindings/power/supply/charger-manager.txt | 30 ++++++++++++-------
>  1 file changed, 20 insertions(+), 10 deletions(-)

I guess you're just documenting what already exists, but I think this is 
not really a binding we want to continue using...

Acked-by: Rob Herring <robh@kernel.org>
diff mbox series

Patch

diff --git a/Documentation/devicetree/bindings/power/supply/charger-manager.txt b/Documentation/devicetree/bindings/power/supply/charger-manager.txt
index ec4fe9de3137..b5ae9061b7a0 100644
--- a/Documentation/devicetree/bindings/power/supply/charger-manager.txt
+++ b/Documentation/devicetree/bindings/power/supply/charger-manager.txt
@@ -3,24 +3,32 @@  charger-manager bindings
 
 Required properties :
  - compatible : "charger-manager"
- - <>-supply : for regulator consumer
- - cm-num-chargers : number of chargers
+ - <>-supply : for regulator consumer, named according to cm-regulator-name
  - cm-chargers : name of chargers
  - cm-fuel-gauge : name of battery fuel gauge
  - subnode <regulator> :
 	- cm-regulator-name : name of charger regulator
 	- subnode <cable> :
-		- cm-cable-name : name of charger cable
+		- cm-cable-name : name of charger cable - one of USB, USB-HOST,
+			SDP, DCP, CDP, ACA, FAST-CHARGER, SLOW-CHARGER, WPT,
+			PD, DOCK, JIG, or MECHANICAL
 		- cm-cable-extcon : name of extcon dev
 (optional)	- cm-cable-min : minimum current of cable
 (optional)	- cm-cable-max : maximum current of cable
 
 Optional properties :
  - cm-name : charger manager's name (default : "battery")
- - cm-poll-mode : polling mode (enum polling_modes)
- - cm-poll-interval : polling interval
- - cm-battery-stat : battery status (enum data_source)
- - cm-fullbatt-* : data for full battery checking
+ - cm-poll-mode : polling mode - 0 for disabled, 1 for always, 2 for when
+	external power is connected, or 3 for when charging.  If not present,
+	then polling is disabled
+ - cm-poll-interval : polling interval (in ms)
+ - cm-battery-stat : battery status - 0 for battery always present, 1 for no
+	battery, 2 to check presence via fuel gauge, or 3 to check presence
+	via charger
+ - cm-fullbatt-vchkdrop-volt : voltage drop (in uV) before restarting charging
+ - cm-fullbatt-voltage : voltage (in uV) of full battery
+ - cm-fullbatt-soc : state of charge to consider as full battery
+ - cm-fullbatt-capacity : capcity (in uAh) to consider as full battery
  - cm-thermal-zone : name of external thermometer's thermal zone
  - cm-battery-* : threshold battery temperature for charging
 	-cold : critical cold temperature of battery for charging
@@ -29,6 +37,10 @@  Optional properties :
 	-temp-diff : temperature difference to allow recharging
  - cm-dis/charging-max = limits of charging duration
 
+Deprecated properties:
+ - cm-num-chargers
+ - cm-fullbatt-vchkdrop-ms
+
 Example :
 	charger-manager@0 {
 		compatible = "charger-manager";
@@ -39,13 +51,11 @@  Example :
 		cm-poll-mode = <1>;
 		cm-poll-interval = <30000>;
 
-		cm-fullbatt-vchkdrop-ms = <30000>;
 		cm-fullbatt-vchkdrop-volt = <150000>;
 		cm-fullbatt-soc = <100>;
 
 		cm-battery-stat = <3>;
 
-		cm-num-chargers = <3>;
 		cm-chargers = "charger0", "charger1", "charger2";
 
 		cm-fuel-gauge = "fuelgauge0";
@@ -71,7 +81,7 @@  Example :
 				cm-cable-max = <500000>;
 			};
 			cable@1 {
-				cm-cable-name = "TA";
+				cm-cable-name = "SDP";
 				cm-cable-extcon = "extcon-dev.0";
 				cm-cable-min = <650000>;
 				cm-cable-max = <675000>;