Quoting Luca Ceresoli (2021-05-27 14:16:47) > On 5P49V6965, when an output is enabled we enable the corresponding > FOD. When this happens for the first time, and specifically when writing > register VC5_OUT_DIV_CONTROL in vc5_clk_out_prepare(), all other outputs > are stopped for a short time and then restarted. > > According to Renesas support this is intended: "The reason for that is VC6E > has synced up all output function". > > This behaviour can be disabled at least on VersaClock 6E devices, of which > only the 5P49V6965 is currently implemented by this driver. This requires > writing bit 7 (bypass_sync{1..4}) in register 0x20..0x50. Those registers > are named "Unused Factory Reserved Register", and the bits are documented > as "Skip VDDO<N> verification", which does not clearly explain the relation > to FOD sync. However according to Renesas support as well as my testing > setting this bit does prevent disabling of all clock outputs when enabling > a FOD. > > See "VersaClock ® 6E Family Register Descriptions and Programming Guide" > (August 30, 2018), Table 116 "Power Up VDD check", page 58: > https://www.renesas.com/us/en/document/mau/versaclock-6e-family-register-descriptions-and-programming-guide > > Signed-off-by: Luca Ceresoli <luca@lucaceresoli.net> > Reviewed-by: Adam Ford <aford173@gmail.com> > > --- Any Fixes tag for this patch?
Hi Stephen, On 02/06/21 10:00, Stephen Boyd wrote: > Quoting Luca Ceresoli (2021-05-27 14:16:47) >> On 5P49V6965, when an output is enabled we enable the corresponding >> FOD. When this happens for the first time, and specifically when writing >> register VC5_OUT_DIV_CONTROL in vc5_clk_out_prepare(), all other outputs >> are stopped for a short time and then restarted. >> >> According to Renesas support this is intended: "The reason for that is VC6E >> has synced up all output function". >> >> This behaviour can be disabled at least on VersaClock 6E devices, of which >> only the 5P49V6965 is currently implemented by this driver. This requires >> writing bit 7 (bypass_sync{1..4}) in register 0x20..0x50. Those registers >> are named "Unused Factory Reserved Register", and the bits are documented >> as "Skip VDDO<N> verification", which does not clearly explain the relation >> to FOD sync. However according to Renesas support as well as my testing >> setting this bit does prevent disabling of all clock outputs when enabling >> a FOD. >> >> See "VersaClock ® 6E Family Register Descriptions and Programming Guide" >> (August 30, 2018), Table 116 "Power Up VDD check", page 58: >> https://www.renesas.com/us/en/document/mau/versaclock-6e-family-register-descriptions-and-programming-guide >> >> Signed-off-by: Luca Ceresoli <luca@lucaceresoli.net> >> Reviewed-by: Adam Ford <aford173@gmail.com> >> >> --- > > Any Fixes tag for this patch? I didn't add any as there is no commit that is clearly introducing the problem. This patch fixes a behavior of the chip, which is there by design by causes problems in some use cases. If a Fixes tag is required than I guess it should be the commit adding support for the 5P49V6965, which is the only supported variant of VC[56] having having the problematic behavior _and_ the reserved register bits to prevent it. However I hardly could blame the author of that code for such a "peculiar" chip behaviour. Do you still want me to add such a tag?
Quoting Luca Ceresoli (2021-06-03 01:44:57) > Hi Stephen, > > On 02/06/21 10:00, Stephen Boyd wrote: > > Quoting Luca Ceresoli (2021-05-27 14:16:47) > >> On 5P49V6965, when an output is enabled we enable the corresponding > >> FOD. When this happens for the first time, and specifically when writing > >> register VC5_OUT_DIV_CONTROL in vc5_clk_out_prepare(), all other outputs > >> are stopped for a short time and then restarted. > >> > >> According to Renesas support this is intended: "The reason for that is VC6E > >> has synced up all output function". > >> > >> This behaviour can be disabled at least on VersaClock 6E devices, of which > >> only the 5P49V6965 is currently implemented by this driver. This requires > >> writing bit 7 (bypass_sync{1..4}) in register 0x20..0x50. Those registers > >> are named "Unused Factory Reserved Register", and the bits are documented > >> as "Skip VDDO<N> verification", which does not clearly explain the relation > >> to FOD sync. However according to Renesas support as well as my testing > >> setting this bit does prevent disabling of all clock outputs when enabling > >> a FOD. > >> > >> See "VersaClock ® 6E Family Register Descriptions and Programming Guide" > >> (August 30, 2018), Table 116 "Power Up VDD check", page 58: > >> https://www.renesas.com/us/en/document/mau/versaclock-6e-family-register-descriptions-and-programming-guide > >> > >> Signed-off-by: Luca Ceresoli <luca@lucaceresoli.net> > >> Reviewed-by: Adam Ford <aford173@gmail.com> > >> > >> --- > > > > Any Fixes tag for this patch? > > I didn't add any as there is no commit that is clearly introducing the > problem. This patch fixes a behavior of the chip, which is there by > design by causes problems in some use cases. > > If a Fixes tag is required than I guess it should be the commit adding > support for the 5P49V6965, which is the only supported variant of VC[56] > having having the problematic behavior _and_ the reserved register bits > to prevent it. However I hardly could blame the author of that code for > such a "peculiar" chip behaviour. Do you still want me to add such a tag? I tend to liberally apply the Fixes tag if something is being fixed. It helps understand that the patch is not introducing a new feature and when the incorrect code was introduced. I can slap on a Fixes tag myself, just not sure what to do.
Hi, On 03/06/21 22:07, Stephen Boyd wrote: > Quoting Luca Ceresoli (2021-06-03 01:44:57) >> Hi Stephen, >> >> On 02/06/21 10:00, Stephen Boyd wrote: >>> Quoting Luca Ceresoli (2021-05-27 14:16:47) >>>> On 5P49V6965, when an output is enabled we enable the corresponding >>>> FOD. When this happens for the first time, and specifically when writing >>>> register VC5_OUT_DIV_CONTROL in vc5_clk_out_prepare(), all other outputs >>>> are stopped for a short time and then restarted. >>>> >>>> According to Renesas support this is intended: "The reason for that is VC6E >>>> has synced up all output function". >>>> >>>> This behaviour can be disabled at least on VersaClock 6E devices, of which >>>> only the 5P49V6965 is currently implemented by this driver. This requires >>>> writing bit 7 (bypass_sync{1..4}) in register 0x20..0x50. Those registers >>>> are named "Unused Factory Reserved Register", and the bits are documented >>>> as "Skip VDDO<N> verification", which does not clearly explain the relation >>>> to FOD sync. However according to Renesas support as well as my testing >>>> setting this bit does prevent disabling of all clock outputs when enabling >>>> a FOD. >>>> >>>> See "VersaClock ® 6E Family Register Descriptions and Programming Guide" >>>> (August 30, 2018), Table 116 "Power Up VDD check", page 58: >>>> https://www.renesas.com/us/en/document/mau/versaclock-6e-family-register-descriptions-and-programming-guide >>>> >>>> Signed-off-by: Luca Ceresoli <luca@lucaceresoli.net> >>>> Reviewed-by: Adam Ford <aford173@gmail.com> >>>> >>>> --- >>> >>> Any Fixes tag for this patch? >> >> I didn't add any as there is no commit that is clearly introducing the >> problem. This patch fixes a behavior of the chip, which is there by >> design by causes problems in some use cases. >> >> If a Fixes tag is required than I guess it should be the commit adding >> support for the 5P49V6965, which is the only supported variant of VC[56] >> having having the problematic behavior _and_ the reserved register bits >> to prevent it. However I hardly could blame the author of that code for >> such a "peculiar" chip behaviour. Do you still want me to add such a tag? > > I tend to liberally apply the Fixes tag if something is being fixed. It > helps understand that the patch is not introducing a new feature and > when the incorrect code was introduced. I can slap on a Fixes tag > myself, just not sure what to do. > If you're OK in adding it while applying, here it is: Fixes: 2bda748e6ad8 ("clk: vc5: Add support for IDT VersaClock 5P49V6965") Thanks.
Quoting Luca Ceresoli (2021-05-27 14:16:47) > On 5P49V6965, when an output is enabled we enable the corresponding > FOD. When this happens for the first time, and specifically when writing > register VC5_OUT_DIV_CONTROL in vc5_clk_out_prepare(), all other outputs > are stopped for a short time and then restarted. > > According to Renesas support this is intended: "The reason for that is VC6E > has synced up all output function". > > This behaviour can be disabled at least on VersaClock 6E devices, of which > only the 5P49V6965 is currently implemented by this driver. This requires > writing bit 7 (bypass_sync{1..4}) in register 0x20..0x50. Those registers > are named "Unused Factory Reserved Register", and the bits are documented > as "Skip VDDO<N> verification", which does not clearly explain the relation > to FOD sync. However according to Renesas support as well as my testing > setting this bit does prevent disabling of all clock outputs when enabling > a FOD. > > See "VersaClock ® 6E Family Register Descriptions and Programming Guide" > (August 30, 2018), Table 116 "Power Up VDD check", page 58: > https://www.renesas.com/us/en/document/mau/versaclock-6e-family-register-descriptions-and-programming-guide > > Signed-off-by: Luca Ceresoli <luca@lucaceresoli.net> > Reviewed-by: Adam Ford <aford173@gmail.com> > > --- Applied to clk-next
diff --git a/drivers/clk/clk-versaclock5.c b/drivers/clk/clk-versaclock5.c index 344cd6c61188..3c737742c2a9 100644 --- a/drivers/clk/clk-versaclock5.c +++ b/drivers/clk/clk-versaclock5.c @@ -69,7 +69,10 @@ #define VC5_FEEDBACK_FRAC_DIV(n) (0x19 + (n)) #define VC5_RC_CONTROL0 0x1e #define VC5_RC_CONTROL1 0x1f -/* Register 0x20 is factory reserved */ + +/* These registers are named "Unused Factory Reserved Registers" */ +#define VC5_RESERVED_X0(idx) (0x20 + ((idx) * 0x10)) +#define VC5_RESERVED_X0_BYPASS_SYNC BIT(7) /* bypass_sync<idx> bit */ /* Output divider control for divider 1,2,3,4 */ #define VC5_OUT_DIV_CONTROL(idx) (0x21 + ((idx) * 0x10)) @@ -87,7 +90,6 @@ #define VC5_OUT_DIV_SKEW_INT(idx, n) (0x2b + ((idx) * 0x10) + (n)) #define VC5_OUT_DIV_INT(idx, n) (0x2d + ((idx) * 0x10) + (n)) #define VC5_OUT_DIV_SKEW_FRAC(idx) (0x2f + ((idx) * 0x10)) -/* Registers 0x30, 0x40, 0x50 are factory reserved */ /* Clock control register for clock 1,2 */ #define VC5_CLK_OUTPUT_CFG(idx, n) (0x60 + ((idx) * 0x2) + (n)) @@ -140,6 +142,8 @@ #define VC5_HAS_INTERNAL_XTAL BIT(0) /* chip has PFD requency doubler */ #define VC5_HAS_PFD_FREQ_DBL BIT(1) +/* chip has bits to disable FOD sync */ +#define VC5_HAS_BYPASS_SYNC_BIT BIT(2) /* Supported IDT VC5 models. */ enum vc5_model { @@ -581,6 +585,23 @@ static int vc5_clk_out_prepare(struct clk_hw *hw) unsigned int src; int ret; + /* + * When enabling a FOD, all currently enabled FODs are briefly + * stopped in order to synchronize all of them. This causes a clock + * disruption to any unrelated chips that might be already using + * other clock outputs. Bypass the sync feature to avoid the issue, + * which is possible on the VersaClock 6E family via reserved + * registers. + */ + if (vc5->chip_info->flags & VC5_HAS_BYPASS_SYNC_BIT) { + ret = regmap_update_bits(vc5->regmap, + VC5_RESERVED_X0(hwdata->num), + VC5_RESERVED_X0_BYPASS_SYNC, + VC5_RESERVED_X0_BYPASS_SYNC); + if (ret) + return ret; + } + /* * If the input mux is disabled, enable it first and * select source from matching FOD. @@ -1166,7 +1187,7 @@ static const struct vc5_chip_info idt_5p49v6965_info = { .model = IDT_VC6_5P49V6965, .clk_fod_cnt = 4, .clk_out_cnt = 5, - .flags = 0, + .flags = VC5_HAS_BYPASS_SYNC_BIT, }; static const struct i2c_device_id vc5_id[] = {