Message ID | 20210811063712.19695-1-o.rempel@pengutronix.de (mailing list archive) |
---|---|
State | Accepted |
Commit | e0ba60509d64a7e91d13d28c247db59bf39d9837 |
Delegated to: | Netdev Maintainers |
Headers | show |
Series | [net-next,v2,1/1] net: phy: nxp-tja11xx: log critical health state | expand |
Context | Check | Description |
---|---|---|
netdev/cover_letter | success | Link |
netdev/fixes_present | success | Link |
netdev/patch_count | success | Link |
netdev/tree_selection | success | Clearly marked for net-next |
netdev/subject_prefix | success | Link |
netdev/cc_maintainers | warning | 1 maintainers not CCed: linux@armlinux.org.uk |
netdev/source_inline | success | Was 0 now: 0 |
netdev/verify_signedoff | success | Link |
netdev/module_param | success | Was 0 now: 0 |
netdev/build_32bit | success | Errors and warnings before: 0 this patch: 0 |
netdev/kdoc | success | Errors and warnings before: 0 this patch: 0 |
netdev/verify_fixes | success | Link |
netdev/checkpatch | success | total: 0 errors, 0 warnings, 0 checks, 42 lines checked |
netdev/build_allmodconfig_warn | success | Errors and warnings before: 0 this patch: 0 |
netdev/header_inline | success | Link |
On Wed, Aug 11, 2021 at 08:37:12AM +0200, Oleksij Rempel wrote: > TJA1102 provides interrupt notification for the critical health states > like overtemperature and undervoltage. > > The overtemperature bit is set if package temperature is beyond 155C°. > This functionality was tested by heating the package up to 200C° > > The undervoltage bit is set if supply voltage drops beyond some critical > threshold. Currently not tested. > > In a typical use case, both of this events should be logged and stored > (or send to some remote system) for further investigations. > > Signed-off-by: Oleksij Rempel <o.rempel@pengutronix.de> Reviewed-by: Andrew Lunn <andrew@lunn.ch> Andrew
Hello: This patch was applied to netdev/net-next.git (refs/heads/master): On Wed, 11 Aug 2021 08:37:12 +0200 you wrote: > TJA1102 provides interrupt notification for the critical health states > like overtemperature and undervoltage. > > The overtemperature bit is set if package temperature is beyond 155C°. > This functionality was tested by heating the package up to 200C° > > The undervoltage bit is set if supply voltage drops beyond some critical > threshold. Currently not tested. > > [...] Here is the summary with links: - [net-next,v2,1/1] net: phy: nxp-tja11xx: log critical health state https://git.kernel.org/netdev/net-next/c/e0ba60509d64 You are awesome, thank you! -- Deet-doot-dot, I am a bot. https://korg.docs.kernel.org/patchwork/pwbot.html
diff --git a/drivers/net/phy/nxp-tja11xx.c b/drivers/net/phy/nxp-tja11xx.c index afd7afa1f498..9944cc501806 100644 --- a/drivers/net/phy/nxp-tja11xx.c +++ b/drivers/net/phy/nxp-tja11xx.c @@ -47,12 +47,14 @@ #define MII_INTSRC_LINK_FAIL BIT(10) #define MII_INTSRC_LINK_UP BIT(9) #define MII_INTSRC_MASK (MII_INTSRC_LINK_FAIL | MII_INTSRC_LINK_UP) -#define MII_INTSRC_TEMP_ERR BIT(1) #define MII_INTSRC_UV_ERR BIT(3) +#define MII_INTSRC_TEMP_ERR BIT(1) #define MII_INTEN 22 #define MII_INTEN_LINK_FAIL BIT(10) #define MII_INTEN_LINK_UP BIT(9) +#define MII_INTEN_UV_ERR BIT(3) +#define MII_INTEN_TEMP_ERR BIT(1) #define MII_COMMSTAT 23 #define MII_COMMSTAT_LINK_UP BIT(15) @@ -607,7 +609,8 @@ static int tja11xx_config_intr(struct phy_device *phydev) if (err) return err; - value = MII_INTEN_LINK_FAIL | MII_INTEN_LINK_UP; + value = MII_INTEN_LINK_FAIL | MII_INTEN_LINK_UP | + MII_INTEN_UV_ERR | MII_INTEN_TEMP_ERR; err = phy_write(phydev, MII_INTEN, value); } else { err = phy_write(phydev, MII_INTEN, value); @@ -622,6 +625,7 @@ static int tja11xx_config_intr(struct phy_device *phydev) static irqreturn_t tja11xx_handle_interrupt(struct phy_device *phydev) { + struct device *dev = &phydev->mdio.dev; int irq_status; irq_status = phy_read(phydev, MII_INTSRC); @@ -630,6 +634,11 @@ static irqreturn_t tja11xx_handle_interrupt(struct phy_device *phydev) return IRQ_NONE; } + if (irq_status & MII_INTSRC_TEMP_ERR) + dev_warn(dev, "Overtemperature error detected (temp > 155C°).\n"); + if (irq_status & MII_INTSRC_UV_ERR) + dev_warn(dev, "Undervoltage error detected.\n"); + if (!(irq_status & MII_INTSRC_MASK)) return IRQ_NONE;
TJA1102 provides interrupt notification for the critical health states like overtemperature and undervoltage. The overtemperature bit is set if package temperature is beyond 155C°. This functionality was tested by heating the package up to 200C° The undervoltage bit is set if supply voltage drops beyond some critical threshold. Currently not tested. In a typical use case, both of this events should be logged and stored (or send to some remote system) for further investigations. Signed-off-by: Oleksij Rempel <o.rempel@pengutronix.de> --- drivers/net/phy/nxp-tja11xx.c | 13 +++++++++++-- 1 file changed, 11 insertions(+), 2 deletions(-)