diff mbox series

[v4,4/4] platform/x86: pmc_atom: improve critclk_systems matching for Siemens PCs

Message ID 20211126141027.16161-5-henning.schild@siemens.com (mailing list archive)
State Handled Elsewhere
Headers show
Series add device drivers for Siemens Industrial PCs | expand

Commit Message

Henning Schild Nov. 26, 2021, 2:10 p.m. UTC
Siemens industrial PCs unfortunately can not always be properly
identified the way we used to. An earlier commit introduced code that
allows proper identification without looking at DMI strings that could
differ based on product branding.
Switch over to that proper way and revert commits that used to collect
the machines based on unstable strings.

Fixes: 648e921888ad ("clk: x86: Stop marking clocks as CLK_IS_CRITICAL")
Fixes: e8796c6c69d1 ("platform/x86: pmc_atom: Add Siemens CONNECT ...")
Fixes: f110d252ae79 ("platform/x86: pmc_atom: Add Siemens SIMATIC ...")
Fixes: ad0d315b4d4e ("platform/x86: pmc_atom: Add Siemens SIMATIC ...")
Tested-by: Michael Haener <michael.haener@siemens.com>
Signed-off-by: Henning Schild <henning.schild@siemens.com>
---
 drivers/platform/x86/pmc_atom.c | 54 ++++++++++++++++++++-------------
 1 file changed, 33 insertions(+), 21 deletions(-)

Comments

Andy Shevchenko Nov. 26, 2021, 2:51 p.m. UTC | #1
On Fri, Nov 26, 2021 at 4:10 PM Henning Schild
<henning.schild@siemens.com> wrote:
>
> Siemens industrial PCs unfortunately can not always be properly
> identified the way we used to. An earlier commit introduced code that
> allows proper identification without looking at DMI strings that could
> differ based on product branding.
> Switch over to that proper way and revert commits that used to collect
> the machines based on unstable strings.

Usually we start a series with fixes, but I guess it's fine here since
this can be taken separately, right?

...

> +#include <linux/platform_data/x86/simatic-ipc.h>

Seems not.  Question is then, what Fixes tags would  mean in this case?
Henning Schild Nov. 26, 2021, 3:25 p.m. UTC | #2
Am Fri, 26 Nov 2021 16:51:00 +0200
schrieb Andy Shevchenko <andy.shevchenko@gmail.com>:

> On Fri, Nov 26, 2021 at 4:10 PM Henning Schild
> <henning.schild@siemens.com> wrote:
> >
> > Siemens industrial PCs unfortunately can not always be properly
> > identified the way we used to. An earlier commit introduced code
> > that allows proper identification without looking at DMI strings
> > that could differ based on product branding.
> > Switch over to that proper way and revert commits that used to
> > collect the machines based on unstable strings.  
> 
> Usually we start a series with fixes, but I guess it's fine here since
> this can be taken separately, right?
> 
> ...

It can not be taken because it needs p1 to work. And p1 is mainly here
for p2 and p3 really. Splitting the patches up into

p1.1
p4
p1.2
p2
p3

would be possible but a lot of work for just that ordering topic i
guess.

> > +#include <linux/platform_data/x86/simatic-ipc.h>  
> 
> Seems not.  Question is then, what Fixes tags would  mean in this
> case?
> 

Which of the several tags confuses you? Maybe i just need to drop a few.

the original problem is
Fixes: 648e921888ad ("clk: x86: Stop marking clocks as CLK_IS_CRITICAL")
which introduced the need for several quirks
Fixes: e8796c6c69d1 ("platform/x86: pmc_atom: Add Siemens CONNECT...")
Fixes: f110d252ae79 ("platform/x86: pmc_atom: Add Siemens SIMATIC...")
Fixes: ad0d315b4d4e ("platform/x86: pmc_atom: Add Siemens SIMATIC...")
These quirks use unstable dmi information. Unstable because the
DMI_PRODUCT_VERSION can be branded. Yes weird ... we do not allow new
ACPI entries but do allow custom dmi ...
p1 introduces the use of stable dmi and p4 brings that into the quirk
table ... fixing all the quirks based on customizable
DMI_PRODUCT_VERSION

Henning
diff mbox series

Patch

diff --git a/drivers/platform/x86/pmc_atom.c b/drivers/platform/x86/pmc_atom.c
index a9d2a4b98e57..a40fae6edc84 100644
--- a/drivers/platform/x86/pmc_atom.c
+++ b/drivers/platform/x86/pmc_atom.c
@@ -13,6 +13,7 @@ 
 #include <linux/io.h>
 #include <linux/platform_data/x86/clk-pmc-atom.h>
 #include <linux/platform_data/x86/pmc_atom.h>
+#include <linux/platform_data/x86/simatic-ipc.h>
 #include <linux/platform_device.h>
 #include <linux/pci.h>
 #include <linux/seq_file.h>
@@ -362,6 +363,30 @@  static void pmc_dbgfs_register(struct pmc_dev *pmc)
 }
 #endif /* CONFIG_DEBUG_FS */
 
+static bool pmc_clk_is_critical = true;
+
+static int dmi_callback(const struct dmi_system_id *d)
+{
+	pr_info("%s critclks quirk enabled\n", d->ident);
+
+	return 1;
+}
+
+static int dmi_callback_siemens(const struct dmi_system_id *d)
+{
+	u32 st_id;
+
+	if (dmi_walk(simatic_ipc_find_dmi_entry_helper, &st_id))
+		goto out;
+
+	if (st_id == SIMATIC_IPC_IPC227E || st_id == SIMATIC_IPC_IPC277E)
+		return dmi_callback(d);
+
+out:
+	pmc_clk_is_critical = false;
+	return 1;
+}
+
 /*
  * Some systems need one or more of their pmc_plt_clks to be
  * marked as critical.
@@ -370,6 +395,7 @@  static const struct dmi_system_id critclk_systems[] = {
 	{
 		/* pmc_plt_clk0 is used for an external HSIC USB HUB */
 		.ident = "MPL CEC1x",
+		.callback = dmi_callback,
 		.matches = {
 			DMI_MATCH(DMI_SYS_VENDOR, "MPL AG"),
 			DMI_MATCH(DMI_PRODUCT_NAME, "CEC10 Family"),
@@ -378,6 +404,7 @@  static const struct dmi_system_id critclk_systems[] = {
 	{
 		/* pmc_plt_clk0 - 3 are used for the 4 ethernet controllers */
 		.ident = "Lex 3I380D",
+		.callback = dmi_callback,
 		.matches = {
 			DMI_MATCH(DMI_SYS_VENDOR, "Lex BayTrail"),
 			DMI_MATCH(DMI_PRODUCT_NAME, "3I380D"),
@@ -386,6 +413,7 @@  static const struct dmi_system_id critclk_systems[] = {
 	{
 		/* pmc_plt_clk* - are used for ethernet controllers */
 		.ident = "Lex 2I385SW",
+		.callback = dmi_callback,
 		.matches = {
 			DMI_MATCH(DMI_SYS_VENDOR, "Lex BayTrail"),
 			DMI_MATCH(DMI_PRODUCT_NAME, "2I385SW"),
@@ -394,30 +422,17 @@  static const struct dmi_system_id critclk_systems[] = {
 	{
 		/* pmc_plt_clk* - are used for ethernet controllers */
 		.ident = "Beckhoff Baytrail",
+		.callback = dmi_callback,
 		.matches = {
 			DMI_MATCH(DMI_SYS_VENDOR, "Beckhoff Automation"),
 			DMI_MATCH(DMI_PRODUCT_FAMILY, "CBxx63"),
 		},
 	},
 	{
-		.ident = "SIMATIC IPC227E",
+		.ident = "SIEMENS AG",
+		.callback = dmi_callback_siemens,
 		.matches = {
 			DMI_MATCH(DMI_SYS_VENDOR, "SIEMENS AG"),
-			DMI_MATCH(DMI_PRODUCT_VERSION, "6ES7647-8B"),
-		},
-	},
-	{
-		.ident = "SIMATIC IPC277E",
-		.matches = {
-			DMI_MATCH(DMI_SYS_VENDOR, "SIEMENS AG"),
-			DMI_MATCH(DMI_PRODUCT_VERSION, "6AV7882-0"),
-		},
-	},
-	{
-		.ident = "CONNECT X300",
-		.matches = {
-			DMI_MATCH(DMI_SYS_VENDOR, "SIEMENS AG"),
-			DMI_MATCH(DMI_PRODUCT_VERSION, "A5E45074588"),
 		},
 	},
 
@@ -429,7 +444,6 @@  static int pmc_setup_clks(struct pci_dev *pdev, void __iomem *pmc_regmap,
 {
 	struct platform_device *clkdev;
 	struct pmc_clk_data *clk_data;
-	const struct dmi_system_id *d = dmi_first_match(critclk_systems);
 
 	clk_data = kzalloc(sizeof(*clk_data), GFP_KERNEL);
 	if (!clk_data)
@@ -437,10 +451,8 @@  static int pmc_setup_clks(struct pci_dev *pdev, void __iomem *pmc_regmap,
 
 	clk_data->base = pmc_regmap; /* offset is added by client */
 	clk_data->clks = pmc_data->clks;
-	if (d) {
-		clk_data->critical = true;
-		pr_info("%s critclks quirk enabled\n", d->ident);
-	}
+	if (dmi_check_system(critclk_systems))
+		clk_data->critical = pmc_clk_is_critical;
 
 	clkdev = platform_device_register_data(&pdev->dev, "clk-pmc-atom",
 					       PLATFORM_DEVID_NONE,