mbox series

[v3,0/6] iio: adc: ad_sigma_delta: Add sequencer support

Message ID 20220322105029.86389-1-alexandru.tachici@analog.com (mailing list archive)
Headers show
Series iio: adc: ad_sigma_delta: Add sequencer support | expand

Message

Alexandru Tachici March 22, 2022, 10:50 a.m. UTC
From: Alexandru Tachici <alexandru.tachici@analog.com>

Some sigma-delta chips support sampling of multiple
channels in continuous mode.

When the operating with more than one channel enabled,
the channel sequencer cycles through the enabled channels
in sequential order, from first channel to the last one.
If a channel is disabled, it is skipped by the sequencer.

If more than one channel is used in continuous mode,
instruct the device to append the status to the SPI transfer
(1 extra byte) every time we receive a sample.
All sigma-delta chips possessing a sampling sequencer have
this ability. Inside the status register there will be
the number of the converted channel. In this way, even
if the CPU won't keep up with the sampling rate, it won't
send to userspace wrong channel samples.

1. Removed the 1 byte .shift from channel spec in AD7124,
it confuses userspace apps (no need to shift right).

2. Add update_scan_mode to AD7124, it is required in order
to enable/disable multiple channels at once

3. Add update_scan_mode to AD7192, it is required in order
to enable/disable multiple channels at once

4. Add sequencer support for sigma_delta library.

5. Add sigma_delta_info values and callbacks for sequencer
support in AD7124.

6. Add sigma_delta_info values and callbacks for sequencer
support in AD7192.

Alexandru Tachici (5):
  iio: adc: ad7124: Remove shift from scan_type
  iio: adc: ad7124: Add update_scan_mode
  iio: adc: ad7192: Add update_scan_mode
  iio: adc: ad7124: add sequencer support
  iio: adc: ad7192: add sequencer support

Lars-Peter Clausen (1):
  iio: adc: ad_sigma_delta: Add sequencer support

Changelog V2 -> V3:
  - ad_sd_buffer_postenable(), aligned (slot * storagebits) to 8 bytes
  - devm_krealloc instead of krealloc for samples_buf in ad_sd_buffer_postenable()
  - in ad_sigma_delta_append_status, check return value before setting .status_appended
  - iio: adc: ad_sigma_delta: Add sequencer support: added explanations on
  desynchronization checking and recovery
  - in ad7124_append_status() modify st->adc_control after write has taken place without errors
  - in ad7124_update_scan_mode() take cfg mutex only once instead of every time a
  set_channel happens
  - in ad7192_disable_all() modify st->conf after write taken place without errors
  - in ad7192_append_status() modify st->mode after write taken place without errors

 drivers/iio/adc/ad7124.c               |  86 ++++++++++++++-
 drivers/iio/adc/ad7192.c               |  64 ++++++++++-
 drivers/iio/adc/ad_sigma_delta.c       | 143 +++++++++++++++++++++++--
 include/linux/iio/adc/ad_sigma_delta.h |  38 +++++++
 4 files changed, 315 insertions(+), 16 deletions(-)

--
2.25.1

Comments

Jonathan Cameron March 22, 2022, 9:30 p.m. UTC | #1
On Tue, 22 Mar 2022 12:50:23 +0200
<alexandru.tachici@analog.com> wrote:

> From: Alexandru Tachici <alexandru.tachici@analog.com>

Hi Alexandru,

I just took another look at this and I'm happy with it.
Will leave it on list for a few more days for others to
take a look though before I queue it up.

Thanks,

Jonathan

> 
> Some sigma-delta chips support sampling of multiple
> channels in continuous mode.
> 
> When the operating with more than one channel enabled,
> the channel sequencer cycles through the enabled channels
> in sequential order, from first channel to the last one.
> If a channel is disabled, it is skipped by the sequencer.
> 
> If more than one channel is used in continuous mode,
> instruct the device to append the status to the SPI transfer
> (1 extra byte) every time we receive a sample.
> All sigma-delta chips possessing a sampling sequencer have
> this ability. Inside the status register there will be
> the number of the converted channel. In this way, even
> if the CPU won't keep up with the sampling rate, it won't
> send to userspace wrong channel samples.
> 
> 1. Removed the 1 byte .shift from channel spec in AD7124,
> it confuses userspace apps (no need to shift right).
> 
> 2. Add update_scan_mode to AD7124, it is required in order
> to enable/disable multiple channels at once
> 
> 3. Add update_scan_mode to AD7192, it is required in order
> to enable/disable multiple channels at once
> 
> 4. Add sequencer support for sigma_delta library.
> 
> 5. Add sigma_delta_info values and callbacks for sequencer
> support in AD7124.
> 
> 6. Add sigma_delta_info values and callbacks for sequencer
> support in AD7192.
> 
> Alexandru Tachici (5):
>   iio: adc: ad7124: Remove shift from scan_type
>   iio: adc: ad7124: Add update_scan_mode
>   iio: adc: ad7192: Add update_scan_mode
>   iio: adc: ad7124: add sequencer support
>   iio: adc: ad7192: add sequencer support
> 
> Lars-Peter Clausen (1):
>   iio: adc: ad_sigma_delta: Add sequencer support
> 
> Changelog V2 -> V3:
>   - ad_sd_buffer_postenable(), aligned (slot * storagebits) to 8 bytes
>   - devm_krealloc instead of krealloc for samples_buf in ad_sd_buffer_postenable()
>   - in ad_sigma_delta_append_status, check return value before setting .status_appended
>   - iio: adc: ad_sigma_delta: Add sequencer support: added explanations on
>   desynchronization checking and recovery
>   - in ad7124_append_status() modify st->adc_control after write has taken place without errors
>   - in ad7124_update_scan_mode() take cfg mutex only once instead of every time a
>   set_channel happens
>   - in ad7192_disable_all() modify st->conf after write taken place without errors
>   - in ad7192_append_status() modify st->mode after write taken place without errors
> 
>  drivers/iio/adc/ad7124.c               |  86 ++++++++++++++-
>  drivers/iio/adc/ad7192.c               |  64 ++++++++++-
>  drivers/iio/adc/ad_sigma_delta.c       | 143 +++++++++++++++++++++++--
>  include/linux/iio/adc/ad_sigma_delta.h |  38 +++++++
>  4 files changed, 315 insertions(+), 16 deletions(-)
> 
> --
> 2.25.1
Jonathan Cameron March 27, 2022, 3:10 p.m. UTC | #2
On Tue, 22 Mar 2022 21:30:02 +0000
Jonathan Cameron <Jonathan.Cameron@Huawei.com> wrote:

> On Tue, 22 Mar 2022 12:50:23 +0200
> <alexandru.tachici@analog.com> wrote:
> 
> > From: Alexandru Tachici <alexandru.tachici@analog.com>  
> 
> Hi Alexandru,
> 
> I just took another look at this and I'm happy with it.
> Will leave it on list for a few more days for others to
> take a look though before I queue it up.
> 
Applied to the togreg branch of iio.git though I won't push
that out, other than as testing, until I can rebase on rc1.

Thanks,

Jonathan
 
> Thanks,
> 
> Jonathan
> 
> > 
> > Some sigma-delta chips support sampling of multiple
> > channels in continuous mode.
> > 
> > When the operating with more than one channel enabled,
> > the channel sequencer cycles through the enabled channels
> > in sequential order, from first channel to the last one.
> > If a channel is disabled, it is skipped by the sequencer.
> > 
> > If more than one channel is used in continuous mode,
> > instruct the device to append the status to the SPI transfer
> > (1 extra byte) every time we receive a sample.
> > All sigma-delta chips possessing a sampling sequencer have
> > this ability. Inside the status register there will be
> > the number of the converted channel. In this way, even
> > if the CPU won't keep up with the sampling rate, it won't
> > send to userspace wrong channel samples.
> > 
> > 1. Removed the 1 byte .shift from channel spec in AD7124,
> > it confuses userspace apps (no need to shift right).
> > 
> > 2. Add update_scan_mode to AD7124, it is required in order
> > to enable/disable multiple channels at once
> > 
> > 3. Add update_scan_mode to AD7192, it is required in order
> > to enable/disable multiple channels at once
> > 
> > 4. Add sequencer support for sigma_delta library.
> > 
> > 5. Add sigma_delta_info values and callbacks for sequencer
> > support in AD7124.
> > 
> > 6. Add sigma_delta_info values and callbacks for sequencer
> > support in AD7192.
> > 
> > Alexandru Tachici (5):
> >   iio: adc: ad7124: Remove shift from scan_type
> >   iio: adc: ad7124: Add update_scan_mode
> >   iio: adc: ad7192: Add update_scan_mode
> >   iio: adc: ad7124: add sequencer support
> >   iio: adc: ad7192: add sequencer support
> > 
> > Lars-Peter Clausen (1):
> >   iio: adc: ad_sigma_delta: Add sequencer support
> > 
> > Changelog V2 -> V3:
> >   - ad_sd_buffer_postenable(), aligned (slot * storagebits) to 8 bytes
> >   - devm_krealloc instead of krealloc for samples_buf in ad_sd_buffer_postenable()
> >   - in ad_sigma_delta_append_status, check return value before setting .status_appended
> >   - iio: adc: ad_sigma_delta: Add sequencer support: added explanations on
> >   desynchronization checking and recovery
> >   - in ad7124_append_status() modify st->adc_control after write has taken place without errors
> >   - in ad7124_update_scan_mode() take cfg mutex only once instead of every time a
> >   set_channel happens
> >   - in ad7192_disable_all() modify st->conf after write taken place without errors
> >   - in ad7192_append_status() modify st->mode after write taken place without errors
> > 
> >  drivers/iio/adc/ad7124.c               |  86 ++++++++++++++-
> >  drivers/iio/adc/ad7192.c               |  64 ++++++++++-
> >  drivers/iio/adc/ad_sigma_delta.c       | 143 +++++++++++++++++++++++--
> >  include/linux/iio/adc/ad_sigma_delta.h |  38 +++++++
> >  4 files changed, 315 insertions(+), 16 deletions(-)
> > 
> > --
> > 2.25.1  
>