On Fri, Feb 03, 2023 at 09:42:37AM +0000, Kiseok Jo wrote: > + sys-clk-id: > + description: > + select the using system clock. > + 0 = External Clock 19.2MHz > + 1 = External Clock 24.576MHz > + 2 = Using PLL in MCLK > + 3 = Using PLL in BCLK > + $ref: "/schemas/types.yaml#/definitions/uint32" > + maximum: 3 > + default: 3 We really shouldn't have this as a custom property, we should be using a combination of the clock bindings. In the driver this would turn into using clk_get() to get the MCLK, then we can query the rate with clk_get_rate() and use option 0 or 1 if the rate matches, or the PLL otherwise. If we fail to get MCLK then we can fall back to using BCLK.
On Fri, Feb 03, 2023 at 09:42:37AM +0000, Kiseok Jo wrote: > Fix according to the writing-schema.rst file and tested. > Add the missing property as compatible, reg, sys-clk-id. > > Signed-off-by: Kiseok Jo <kiseok.jo@irondevice.com> > --- > .../bindings/sound/irondevice,sma1303.yaml | 35 +++++++++++++++++-- > 1 file changed, 32 insertions(+), 3 deletions(-) What's the output of 'make dt_binding_check'? Asking since linux-next has been broken in different ways with this schema. Rob
> > Fix according to the writing-schema.rst file and tested. > > Add the missing property as compatible, reg, sys-clk-id. > > > > Signed-off-by: Kiseok Jo <kiseok.jo@irondevice.com> > > --- > > .../bindings/sound/irondevice,sma1303.yaml | 35 +++++++++++++++++-- > > 1 file changed, 32 insertions(+), 3 deletions(-) > > What's the output of 'make dt_binding_check'? Asking since linux-next has > been broken in different ways with this schema. > > Rob 2 logs and 2 files output below: DTEX irondevice,sma1303.example.dts DTC_CHK irondevice,sma1303.example.dtb And I didn't see any other error, so I thought it was okay. Is there anything else I need to check or how? I'll try it. Thank you! Best Regard, Kiseok Jo
> > > + sys-clk-id: > > + description: > > + select the using system clock. > > + 0 = External Clock 19.2MHz > > + 1 = External Clock 24.576MHz > > + 2 = Using PLL in MCLK > > + 3 = Using PLL in BCLK > > + $ref: "/schemas/types.yaml#/definitions/uint32" > > + maximum: 3 > > + default: 3 > > We really shouldn't have this as a custom property, we should be using a > combination of the clock bindings. > > In the driver this would turn into using clk_get() to get the MCLK, then > we can query the rate with clk_get_rate() and use option 0 or 1 if the > rate matches, or the PLL otherwise. If we fail to get MCLK then we can > fall back to using BCLK. Okay, I got it. I'll make it based on what you sent me using other drivers. Thanks, your feedback. Best regards, Kiseok Jo
diff --git a/Documentation/devicetree/bindings/sound/irondevice,sma1303.yaml b/Documentation/devicetree/bindings/sound/irondevice,sma1303.yaml index 162c52606635..2c6158277aee 100644 --- a/Documentation/devicetree/bindings/sound/irondevice,sma1303.yaml +++ b/Documentation/devicetree/bindings/sound/irondevice,sma1303.yaml @@ -10,22 +10,51 @@ maintainers: - Kiseok Jo <kiseok.jo@irondevice.com> description: - SMA1303 digital class-D audio amplifier with an integrated boost converter. + SMA1303 digital class-D audio amplifier + with an integrated boost converter. allOf: - - $ref: name-prefix.yaml# + - $ref: dai-common.yaml# + +properties: + compatible: + enum: + - irondevice,sma1303 + + reg: + maxItems: 1 + + '#sound-dai-cells': + const: 1 + + sys-clk-id: + description: + select the using system clock. + 0 = External Clock 19.2MHz + 1 = External Clock 24.576MHz + 2 = Using PLL in MCLK + 3 = Using PLL in BCLK + $ref: "/schemas/types.yaml#/definitions/uint32" + maximum: 3 + default: 3 required: - compatible - reg + - '#sound-dai-cells' additionalProperties: false examples: - | - i2c_bus { + i2c { + #address-cells = <1>; + #size-cells = <0>; + amplifier@1e { compatible = "irondevice,sma1303"; reg = <0x1e>; + #sound-dai-cells = <1>; + sys-clk-id = <3>; }; };
Fix according to the writing-schema.rst file and tested. Add the missing property as compatible, reg, sys-clk-id. Signed-off-by: Kiseok Jo <kiseok.jo@irondevice.com> --- .../bindings/sound/irondevice,sma1303.yaml | 35 +++++++++++++++++-- 1 file changed, 32 insertions(+), 3 deletions(-) base-commit: afdf57285d1e16a1bbdbf6cc33fb22fb6c8e7860