Hi Stefan, On Sun, Mar 5, 2023 at 7:59 PM Stefan Wahren <stefan.wahren@i2se.com> wrote: > > According to fsl,imx-gpc.yaml the General Power Control requires > a ipg clock and a Power Gating Control node. So add them to fix > the dtbs_check warnings on i.MX6UL boards: > > gpc@20dc000: 'clocks' is a required property > gpc@20dc000: 'clock-names' is a required property > gpc@20dc000: 'pgc' is a required property There is a typo in the Subject: s/GDC/GPC.
diff --git a/arch/arm/boot/dts/imx6ul.dtsi b/arch/arm/boot/dts/imx6ul.dtsi index 412baa848837..fd6c064fa032 100644 --- a/arch/arm/boot/dts/imx6ul.dtsi +++ b/arch/arm/boot/dts/imx6ul.dtsi @@ -720,6 +720,18 @@ gpc: gpc@20dc000 { #interrupt-cells = <3>; interrupts = <GIC_SPI 89 IRQ_TYPE_LEVEL_HIGH>; interrupt-parent = <&intc>; + clocks = <&clks IMX6UL_CLK_IPG>; + clock-names = "ipg"; + + pgc { + #address-cells = <1>; + #size-cells = <0>; + + power-domain@0 { + reg = <0>; + #power-domain-cells = <0>; + }; + }; }; iomuxc: pinctrl@20e0000 {
According to fsl,imx-gpc.yaml the General Power Control requires a ipg clock and a Power Gating Control node. So add them to fix the dtbs_check warnings on i.MX6UL boards: gpc@20dc000: 'clocks' is a required property gpc@20dc000: 'clock-names' is a required property gpc@20dc000: 'pgc' is a required property Suggested-by: Jacky Bai <ping.bai@nxp.com> Signed-off-by: Stefan Wahren <stefan.wahren@i2se.com> --- arch/arm/boot/dts/imx6ul.dtsi | 12 ++++++++++++ 1 file changed, 12 insertions(+)