Message ID | 20230712081124.110345-1-krzysztof.kozlowski@linaro.org (mailing list archive) |
---|---|
State | Handled Elsewhere |
Headers | show |
Series | dt-bindings: hwmon: moortec,mr75203: fix multipleOf for coefficients | expand |
On 7/12/2023 11:11 AM, Krzysztof Kozlowski wrote: > Few coefficients use default values multiple of 100, not 1000 (in the > example DTS and in the Linux driver): > > moortec,mr75203.example.dtb: pvt@e0680000: moortec,ts-coeff-g:0:0: > 61400 is not a multiple of 1000 Why isn't multiple of 1000 correct? According to the Moortec datasheet for the series 6 of the temperature sensor the coefficients are: G = 57.4 (57.4 * 1000 = 57400) H = 249.4 For series 5 coefficients are: G = 60 (60 * 1000 = 60000) H = 200 J = -0.1 > Fixes: bf1fdafdbc61 ("dt-bindings: hwmon: (mr75203) add coefficient > properties for the thermal equation") > Signed-off-by: Krzysztof Kozlowski <krzysztof.kozlowski@linaro.org> > --- > .../devicetree/bindings/hwmon/moortec,mr75203.yaml | 6 +++--- > 1 file changed, 3 insertions(+), 3 deletions(-) > > diff --git > a/Documentation/devicetree/bindings/hwmon/moortec,mr75203.yaml > b/Documentation/devicetree/bindings/hwmon/moortec,mr75203.yaml > index ae4f68d4e696..bd67cfee6d19 100644 > --- a/Documentation/devicetree/bindings/hwmon/moortec,mr75203.yaml > +++ b/Documentation/devicetree/bindings/hwmon/moortec,mr75203.yaml > @@ -105,7 +105,7 @@ properties: > G coefficient for temperature equation. > Default for series 5 = 60000 > Default for series 6 = 57400 > - multipleOf: 1000 > + multipleOf: 100 > minimum: 1000 > $ref: /schemas/types.yaml#/definitions/uint32 > > @@ -114,7 +114,7 @@ properties: > H coefficient for temperature equation. > Default for series 5 = 200000 > Default for series 6 = 249400 > - multipleOf: 1000 > + multipleOf: 100 > minimum: 1000 > $ref: /schemas/types.yaml#/definitions/uint32 > > @@ -131,7 +131,7 @@ properties: > J coefficient for temperature equation. > Default for series 5 = -100 > Default for series 6 = 0 > - multipleOf: 1000 > + multipleOf: 100 > maximum: 0 > $ref: /schemas/types.yaml#/definitions/int32 > > -- > 2.34.1 >
On 12/07/2023 13:58, Farber, Eliav wrote: > On 7/12/2023 11:11 AM, Krzysztof Kozlowski wrote: >> Few coefficients use default values multiple of 100, not 1000 (in the >> example DTS and in the Linux driver): >> >> moortec,mr75203.example.dtb: pvt@e0680000: moortec,ts-coeff-g:0:0: >> 61400 is not a multiple of 1000 > > Why isn't multiple of 1000 correct? 61400 is not a multiple of 1000, at least not in integers. 61400 is a multiple of 100. > According to the Moortec datasheet for the series 6 of the temperature > sensor > the coefficients are: > G = 57.4 (57.4 * 1000 = 57400) 57.4 is not integer. With that approach 1 is also multiple of 1000, because: G = 1 * 0.001 * 1000. > H = 249.4 > For series 5 coefficients are: > G = 60 (60 * 1000 = 60000) > H = 200 > J = -0.1 Trim the context of replies. No need to quote entire text below. Best regards, Krzysztof
On Wed, 12 Jul 2023 10:11:24 +0200, Krzysztof Kozlowski wrote: > Few coefficients use default values multiple of 100, not 1000 (in the > example DTS and in the Linux driver): > > moortec,mr75203.example.dtb: pvt@e0680000: moortec,ts-coeff-g:0:0: 61400 is not a multiple of 1000 > > Fixes: bf1fdafdbc61 ("dt-bindings: hwmon: (mr75203) add coefficient properties for the thermal equation") > Signed-off-by: Krzysztof Kozlowski <krzysztof.kozlowski@linaro.org> > --- > .../devicetree/bindings/hwmon/moortec,mr75203.yaml | 6 +++--- > 1 file changed, 3 insertions(+), 3 deletions(-) > Applied, thanks!
diff --git a/Documentation/devicetree/bindings/hwmon/moortec,mr75203.yaml b/Documentation/devicetree/bindings/hwmon/moortec,mr75203.yaml index ae4f68d4e696..bd67cfee6d19 100644 --- a/Documentation/devicetree/bindings/hwmon/moortec,mr75203.yaml +++ b/Documentation/devicetree/bindings/hwmon/moortec,mr75203.yaml @@ -105,7 +105,7 @@ properties: G coefficient for temperature equation. Default for series 5 = 60000 Default for series 6 = 57400 - multipleOf: 1000 + multipleOf: 100 minimum: 1000 $ref: /schemas/types.yaml#/definitions/uint32 @@ -114,7 +114,7 @@ properties: H coefficient for temperature equation. Default for series 5 = 200000 Default for series 6 = 249400 - multipleOf: 1000 + multipleOf: 100 minimum: 1000 $ref: /schemas/types.yaml#/definitions/uint32 @@ -131,7 +131,7 @@ properties: J coefficient for temperature equation. Default for series 5 = -100 Default for series 6 = 0 - multipleOf: 1000 + multipleOf: 100 maximum: 0 $ref: /schemas/types.yaml#/definitions/int32
Few coefficients use default values multiple of 100, not 1000 (in the example DTS and in the Linux driver): moortec,mr75203.example.dtb: pvt@e0680000: moortec,ts-coeff-g:0:0: 61400 is not a multiple of 1000 Fixes: bf1fdafdbc61 ("dt-bindings: hwmon: (mr75203) add coefficient properties for the thermal equation") Signed-off-by: Krzysztof Kozlowski <krzysztof.kozlowski@linaro.org> --- .../devicetree/bindings/hwmon/moortec,mr75203.yaml | 6 +++--- 1 file changed, 3 insertions(+), 3 deletions(-)