Message ID | 20240224202053.25313-14-semen.protsenko@linaro.org (mailing list archive) |
---|---|
State | Deferred |
Headers | show |
Series | clk: samsung: Add CPU clocks for Exynos850 | expand |
On 24/02/2024 21:20, Sam Protsenko wrote: > Some ARM64 Exynos chips are capable to control PLL clocks automatically. > For those chips, whether the PLL is controlled automatically or manually > is chosen in PLL_CON1 register with next bits: > > [28] ENABLE_AUTOMATIC_CLKGATING > [1] MANUAL_PLL_CTRL > [0] AUTO_PLL_CTRL > > The bl2 bootloader sets 0x10000001 value for some PLL_CON1 registers, > which means any attempt to control those PLLs manually (e.g. > disabling/enabling those PLLs or changing MUX parent clocks) would lead > to PLL lock timeout with error message like this: > > Could not lock PLL ... > > At the moment, all Samsung clock drivers implement manual clock control. > So in order to make it possible to control PLLs, corresponding PLL_CON1 > registers should be set to 0x2 first. > > Some older ARM64 chips don't implement the automatic clock control > though. It also might be desirable to configure some PLLs for manual > control, while keeping the default configuration for the rest. So it'd > convenient to choose this PLL mode for each CMU separately. Introduce > .manual_plls field to CMU structure to choose the PLL control mode. > Because it'll be initialized with "false" in all existing CMU > structures by default, it won't affect any existing clock drivers, > allowing for this feature to be enabled gradually when it's needed with > no change for the rest of users. In case .manual_plls is set, set > PLL_CON1 registers to manual control, akin to what's already done for > gate clocks in exynos_arm64_init_clocks(). Of course, PLL_CON1 registers > should be added to corresponding struct samsung_cmu_info::clk_regs array > to make sure they get initialized. > > No functional change. This patch adds a feature, but doesn't enable it > for any users. > > Signed-off-by: Sam Protsenko <semen.protsenko@linaro.org> > --- > Changes in v3: > - none > > Changes in v2: > - none > > drivers/clk/samsung/clk-exynos-arm64.c | 44 +++++++++++++++++--------- > drivers/clk/samsung/clk.h | 4 +++ > 2 files changed, 33 insertions(+), 15 deletions(-) > > diff --git a/drivers/clk/samsung/clk-exynos-arm64.c b/drivers/clk/samsung/clk-exynos-arm64.c > index 6fb7194df7ab..55490209b9a9 100644 > --- a/drivers/clk/samsung/clk-exynos-arm64.c > +++ b/drivers/clk/samsung/clk-exynos-arm64.c > @@ -25,6 +25,19 @@ > #define GATE_OFF_START 0x2000 > #define GATE_OFF_END 0x2fff > > +/* PLL CON register offsets range */ > +#define PLL_CON_START 0x100 > +#define PLL_CON_END 0x600 > + > +/* PLL register bits */ > +#define PLL_CON1_MANUAL BIT(1) > + > +/* Helper macros to check for particular clock regiter by its offset */ > +#define IS_GATE_REG(o) ((o) >= GATE_OFF_START && (o) <= GATE_OFF_END) > +#define IS_PLL_CONx_REG(o) ((o) >= PLL_CON_START && (o) <= PLL_CON_END) > +#define IS_PLL_CON1_REG(o) \ > + (IS_PLL_CONx_REG(o) && ((o) & 0xf) == 0x4 && !((o) & 0x10)) These should be static functions, because it leads to trickier code. See also checkpatch warning. Best regards, Krzysztof
On Sun, Feb 25, 2024 at 10:09 AM Krzysztof Kozlowski <krzysztof.kozlowski@linaro.org> wrote: > > On 24/02/2024 21:20, Sam Protsenko wrote: > > Some ARM64 Exynos chips are capable to control PLL clocks automatically. > > For those chips, whether the PLL is controlled automatically or manually > > is chosen in PLL_CON1 register with next bits: > > > > [28] ENABLE_AUTOMATIC_CLKGATING > > [1] MANUAL_PLL_CTRL > > [0] AUTO_PLL_CTRL > > > > The bl2 bootloader sets 0x10000001 value for some PLL_CON1 registers, > > which means any attempt to control those PLLs manually (e.g. > > disabling/enabling those PLLs or changing MUX parent clocks) would lead > > to PLL lock timeout with error message like this: > > > > Could not lock PLL ... > > > > At the moment, all Samsung clock drivers implement manual clock control. > > So in order to make it possible to control PLLs, corresponding PLL_CON1 > > registers should be set to 0x2 first. > > > > Some older ARM64 chips don't implement the automatic clock control > > though. It also might be desirable to configure some PLLs for manual > > control, while keeping the default configuration for the rest. So it'd > > convenient to choose this PLL mode for each CMU separately. Introduce > > .manual_plls field to CMU structure to choose the PLL control mode. > > Because it'll be initialized with "false" in all existing CMU > > structures by default, it won't affect any existing clock drivers, > > allowing for this feature to be enabled gradually when it's needed with > > no change for the rest of users. In case .manual_plls is set, set > > PLL_CON1 registers to manual control, akin to what's already done for > > gate clocks in exynos_arm64_init_clocks(). Of course, PLL_CON1 registers > > should be added to corresponding struct samsung_cmu_info::clk_regs array > > to make sure they get initialized. > > > > No functional change. This patch adds a feature, but doesn't enable it > > for any users. > > > > Signed-off-by: Sam Protsenko <semen.protsenko@linaro.org> > > --- > > Changes in v3: > > - none > > > > Changes in v2: > > - none > > > > drivers/clk/samsung/clk-exynos-arm64.c | 44 +++++++++++++++++--------- > > drivers/clk/samsung/clk.h | 4 +++ > > 2 files changed, 33 insertions(+), 15 deletions(-) > > > > diff --git a/drivers/clk/samsung/clk-exynos-arm64.c b/drivers/clk/samsung/clk-exynos-arm64.c > > index 6fb7194df7ab..55490209b9a9 100644 > > --- a/drivers/clk/samsung/clk-exynos-arm64.c > > +++ b/drivers/clk/samsung/clk-exynos-arm64.c > > @@ -25,6 +25,19 @@ > > #define GATE_OFF_START 0x2000 > > #define GATE_OFF_END 0x2fff > > > > +/* PLL CON register offsets range */ > > +#define PLL_CON_START 0x100 > > +#define PLL_CON_END 0x600 > > + > > +/* PLL register bits */ > > +#define PLL_CON1_MANUAL BIT(1) > > + > > +/* Helper macros to check for particular clock regiter by its offset */ > > +#define IS_GATE_REG(o) ((o) >= GATE_OFF_START && (o) <= GATE_OFF_END) > > +#define IS_PLL_CONx_REG(o) ((o) >= PLL_CON_START && (o) <= PLL_CON_END) > > +#define IS_PLL_CON1_REG(o) \ > > + (IS_PLL_CONx_REG(o) && ((o) & 0xf) == 0x4 && !((o) & 0x10)) > > These should be static functions, because it leads to trickier code. See > also checkpatch warning. > For my taste macros are more compact in this particular case. But I don't mind, will send out the reworked patches soon. > Best regards, > Krzysztof >
diff --git a/drivers/clk/samsung/clk-exynos-arm64.c b/drivers/clk/samsung/clk-exynos-arm64.c index 6fb7194df7ab..55490209b9a9 100644 --- a/drivers/clk/samsung/clk-exynos-arm64.c +++ b/drivers/clk/samsung/clk-exynos-arm64.c @@ -25,6 +25,19 @@ #define GATE_OFF_START 0x2000 #define GATE_OFF_END 0x2fff +/* PLL CON register offsets range */ +#define PLL_CON_START 0x100 +#define PLL_CON_END 0x600 + +/* PLL register bits */ +#define PLL_CON1_MANUAL BIT(1) + +/* Helper macros to check for particular clock regiter by its offset */ +#define IS_GATE_REG(o) ((o) >= GATE_OFF_START && (o) <= GATE_OFF_END) +#define IS_PLL_CONx_REG(o) ((o) >= PLL_CON_START && (o) <= PLL_CON_END) +#define IS_PLL_CON1_REG(o) \ + (IS_PLL_CONx_REG(o) && ((o) & 0xf) == 0x4 && !((o) & 0x10)) + struct exynos_arm64_cmu_data { struct samsung_clk_reg_dump *clk_save; unsigned int nr_clk_save; @@ -40,15 +53,16 @@ struct exynos_arm64_cmu_data { /** * exynos_arm64_init_clocks - Set clocks initial configuration - * @np: CMU device tree node with "reg" property (CMU addr) - * @reg_offs: Register offsets array for clocks to init - * @reg_offs_len: Number of register offsets in reg_offs array + * @np: CMU device tree node with "reg" property (CMU addr) + * @cmu: CMU data * - * Set manual control mode for all gate clocks. + * Set manual control mode for all gate and PLL clocks. */ static void __init exynos_arm64_init_clocks(struct device_node *np, - const unsigned long *reg_offs, size_t reg_offs_len) + const struct samsung_cmu_info *cmu) { + const unsigned long *reg_offs = cmu->clk_regs; + size_t reg_offs_len = cmu->nr_clk_regs; void __iomem *reg_base; size_t i; @@ -60,14 +74,14 @@ static void __init exynos_arm64_init_clocks(struct device_node *np, void __iomem *reg = reg_base + reg_offs[i]; u32 val; - /* Modify only gate clock registers */ - if (reg_offs[i] < GATE_OFF_START || reg_offs[i] > GATE_OFF_END) - continue; - - val = readl(reg); - val |= GATE_MANUAL; - val &= ~GATE_ENABLE_HWACG; - writel(val, reg); + if (cmu->manual_plls && IS_PLL_CON1_REG(reg_offs[i])) { + writel(PLL_CON1_MANUAL, reg); + } else if (IS_GATE_REG(reg_offs[i])) { + val = readl(reg); + val |= GATE_MANUAL; + val &= ~GATE_ENABLE_HWACG; + writel(val, reg); + } } iounmap(reg_base); @@ -177,7 +191,7 @@ void __init exynos_arm64_register_cmu(struct device *dev, pr_err("%s: could not enable bus clock %s; err = %d\n", __func__, cmu->clk_name, err); - exynos_arm64_init_clocks(np, cmu->clk_regs, cmu->nr_clk_regs); + exynos_arm64_init_clocks(np, cmu); samsung_cmu_register_one(np, cmu); } @@ -224,7 +238,7 @@ int __init exynos_arm64_register_cmu_pm(struct platform_device *pdev, __func__, cmu->clk_name, ret); if (set_manual) - exynos_arm64_init_clocks(np, cmu->clk_regs, cmu->nr_clk_regs); + exynos_arm64_init_clocks(np, cmu); reg_base = devm_platform_ioremap_resource(pdev, 0); if (IS_ERR(reg_base)) diff --git a/drivers/clk/samsung/clk.h b/drivers/clk/samsung/clk.h index a763309e6f12..a70bd7cce39f 100644 --- a/drivers/clk/samsung/clk.h +++ b/drivers/clk/samsung/clk.h @@ -330,6 +330,7 @@ struct samsung_clock_reg_cache { * @suspend_regs: list of clock registers to set before suspend * @nr_suspend_regs: count of clock registers in @suspend_regs * @clk_name: name of the parent clock needed for CMU register access + * @manual_plls: Enable manual control for PLL clocks */ struct samsung_cmu_info { const struct samsung_pll_clock *pll_clks; @@ -354,6 +355,9 @@ struct samsung_cmu_info { const struct samsung_clk_reg_dump *suspend_regs; unsigned int nr_suspend_regs; const char *clk_name; + + /* ARM64 Exynos CMUs */ + bool manual_plls; }; struct samsung_clk_provider *samsung_clk_init(struct device *dev,
Some ARM64 Exynos chips are capable to control PLL clocks automatically. For those chips, whether the PLL is controlled automatically or manually is chosen in PLL_CON1 register with next bits: [28] ENABLE_AUTOMATIC_CLKGATING [1] MANUAL_PLL_CTRL [0] AUTO_PLL_CTRL The bl2 bootloader sets 0x10000001 value for some PLL_CON1 registers, which means any attempt to control those PLLs manually (e.g. disabling/enabling those PLLs or changing MUX parent clocks) would lead to PLL lock timeout with error message like this: Could not lock PLL ... At the moment, all Samsung clock drivers implement manual clock control. So in order to make it possible to control PLLs, corresponding PLL_CON1 registers should be set to 0x2 first. Some older ARM64 chips don't implement the automatic clock control though. It also might be desirable to configure some PLLs for manual control, while keeping the default configuration for the rest. So it'd convenient to choose this PLL mode for each CMU separately. Introduce .manual_plls field to CMU structure to choose the PLL control mode. Because it'll be initialized with "false" in all existing CMU structures by default, it won't affect any existing clock drivers, allowing for this feature to be enabled gradually when it's needed with no change for the rest of users. In case .manual_plls is set, set PLL_CON1 registers to manual control, akin to what's already done for gate clocks in exynos_arm64_init_clocks(). Of course, PLL_CON1 registers should be added to corresponding struct samsung_cmu_info::clk_regs array to make sure they get initialized. No functional change. This patch adds a feature, but doesn't enable it for any users. Signed-off-by: Sam Protsenko <semen.protsenko@linaro.org> --- Changes in v3: - none Changes in v2: - none drivers/clk/samsung/clk-exynos-arm64.c | 44 +++++++++++++++++--------- drivers/clk/samsung/clk.h | 4 +++ 2 files changed, 33 insertions(+), 15 deletions(-)