On Tue, 18 Jun 2024 16:26:29 +0100, Biju Das wrote: > As per the latest HW manual[1], the INT# output is pulled low after the > alarm is triggered. After the INT# output is pulled low, it is low for at > least 250ms, even if the correct action is taken to clear it. It is > impossible to clear ALM if it is still active. The host must wait for the > RTC to progress past the alarm time plus the 250ms delay before clearing > ALM. Apart from this, there is an internal delay(~250 microsec) from > setting ALME = 0 to disabling the alarm function, so the user must add a > short delay of greater than 250µs between setting ALME = 0 and clearing > ALM. > > [...] Applied, thanks! [1/2] rtc: isl1208: Add a delay for clearing alarm https://git.kernel.org/abelloni/c/0dbd610c426e [2/2] rtc: isl1208: Update correct procedure for clearing alarm https://git.kernel.org/abelloni/c/43696b3a9e46 Best regards,