diff mbox series

[v4,1/7] iio: pressure: bmp280: Use bulk read for humidity calibration data

Message ID 20240828205128.92145-2-vassilisamir@gmail.com (mailing list archive)
State Changes Requested
Headers show
Series pressure: bmp280: Minor cleanup and interrupt support | expand

Commit Message

Vasileios Amoiridis Aug. 28, 2024, 8:51 p.m. UTC
Convert individual reads to a bulk read for the humidity calibration data.

Signed-off-by: Vasileios Amoiridis <vassilisamir@gmail.com>
---
 drivers/iio/pressure/bmp280-core.c | 64 +++++++++++-------------------
 drivers/iio/pressure/bmp280.h      |  6 +++
 2 files changed, 29 insertions(+), 41 deletions(-)

Comments

Andy Shevchenko Aug. 29, 2024, 12:06 p.m. UTC | #1
On Wed, Aug 28, 2024 at 10:51:21PM +0200, Vasileios Amoiridis wrote:
> Convert individual reads to a bulk read for the humidity calibration data.

...

> +	calib->H2 = get_unaligned_le16(&data->bme280_humid_cal_buf[H2]);
> +	calib->H3 = data->bme280_humid_cal_buf[H3];
> +	tmp_1 = get_unaligned_be16(&data->bme280_humid_cal_buf[H4]);
> +	tmp_2 = FIELD_GET(BME280_COMP_H4_GET_MASK_UP, tmp_1);
> +	h4_upper = FIELD_PREP(BME280_COMP_H4_PREP_MASK_UP, tmp_2);
> +	h4_lower = FIELD_GET(BME280_COMP_H4_MASK_LOW,

> +			get_unaligned_be16(&data->bme280_humid_cal_buf[H4]));

Either I don't understand the side effects, or this is the same as tmp_1. No?

> +	calib->H4 = sign_extend32(h4_upper | h4_lower, 11);
> +	calib->H5 = sign_extend32(FIELD_GET(BME280_COMP_H5_MASK,
> +			get_unaligned_le16(&data->bme280_humid_cal_buf[H5])), 11);
> +	calib->H6 = data->bme280_humid_cal_buf[H6];
Vasileios Amoiridis Aug. 29, 2024, 6:57 p.m. UTC | #2
On Thu, Aug 29, 2024 at 03:06:14PM +0300, Andy Shevchenko wrote:
> On Wed, Aug 28, 2024 at 10:51:21PM +0200, Vasileios Amoiridis wrote:
> > Convert individual reads to a bulk read for the humidity calibration data.
> 
> ...
> 
> > +	calib->H2 = get_unaligned_le16(&data->bme280_humid_cal_buf[H2]);
> > +	calib->H3 = data->bme280_humid_cal_buf[H3];
> > +	tmp_1 = get_unaligned_be16(&data->bme280_humid_cal_buf[H4]);
> > +	tmp_2 = FIELD_GET(BME280_COMP_H4_GET_MASK_UP, tmp_1);
> > +	h4_upper = FIELD_PREP(BME280_COMP_H4_PREP_MASK_UP, tmp_2);
> > +	h4_lower = FIELD_GET(BME280_COMP_H4_MASK_LOW,
> 
> > +			get_unaligned_be16(&data->bme280_humid_cal_buf[H4]));
> 
> Either I don't understand the side effects, or this is the same as tmp_1. No?
> 

Hi Andy,

Thanks again for taking the time to review this!

This is the same as tmp1, and I didn't notice that I should change it.
Thanks for pointing it out.

Cheers,
Vasilis
> > +	calib->H4 = sign_extend32(h4_upper | h4_lower, 11);
> > +	calib->H5 = sign_extend32(FIELD_GET(BME280_COMP_H5_MASK,
> > +			get_unaligned_le16(&data->bme280_humid_cal_buf[H5])), 11);
> > +	calib->H6 = data->bme280_humid_cal_buf[H6];
> 
> -- 
> With Best Regards,
> Andy Shevchenko
> 
>
diff mbox series

Patch

diff --git a/drivers/iio/pressure/bmp280-core.c b/drivers/iio/pressure/bmp280-core.c
index 8383d1a73cf9..9c705f2c4a7b 100644
--- a/drivers/iio/pressure/bmp280-core.c
+++ b/drivers/iio/pressure/bmp280-core.c
@@ -340,10 +340,19 @@  static int bmp280_read_calib(struct bmp280_data *data)
 	return 0;
 }
 
+/*
+ * These enums are used for indexing into the array of humidity parameters
+ * for BME280. Due to some weird indexing, unaligned BE/LE accesses co-exist in
+ * order to prepare the FIELD_{GET/PREP}() fields. Table 16 in Section 4.2.2 of
+ * the datasheet.
+ */
+enum { H2 = 0, H3 = 2, H4 = 3, H5 = 4, H6 = 6 };
+
 static int bme280_read_calib(struct bmp280_data *data)
 {
 	struct bmp280_calib *calib = &data->calib.bmp280;
 	struct device *dev = data->dev;
+	s16 h4_upper, h4_lower, tmp_1, tmp_2;
 	unsigned int tmp;
 	int ret;
 
@@ -352,14 +361,6 @@  static int bme280_read_calib(struct bmp280_data *data)
 	if (ret)
 		return ret;
 
-	/*
-	 * Read humidity calibration values.
-	 * Due to some odd register addressing we cannot just
-	 * do a big bulk read. Instead, we have to read each Hx
-	 * value separately and sometimes do some bit shifting...
-	 * Humidity data is only available on BME280.
-	 */
-
 	ret = regmap_read(data->regmap, BME280_REG_COMP_H1, &tmp);
 	if (ret) {
 		dev_err(dev, "failed to read H1 comp value\n");
@@ -368,43 +369,24 @@  static int bme280_read_calib(struct bmp280_data *data)
 	calib->H1 = tmp;
 
 	ret = regmap_bulk_read(data->regmap, BME280_REG_COMP_H2,
-			       &data->le16, sizeof(data->le16));
-	if (ret) {
-		dev_err(dev, "failed to read H2 comp value\n");
-		return ret;
-	}
-	calib->H2 = sign_extend32(le16_to_cpu(data->le16), 15);
-
-	ret = regmap_read(data->regmap, BME280_REG_COMP_H3, &tmp);
-	if (ret) {
-		dev_err(dev, "failed to read H3 comp value\n");
-		return ret;
-	}
-	calib->H3 = tmp;
-
-	ret = regmap_bulk_read(data->regmap, BME280_REG_COMP_H4,
-			       &data->be16, sizeof(data->be16));
+			       data->bme280_humid_cal_buf,
+			       sizeof(data->bme280_humid_cal_buf));
 	if (ret) {
-		dev_err(dev, "failed to read H4 comp value\n");
+		dev_err(dev, "failed to read humidity calibration values\n");
 		return ret;
 	}
-	calib->H4 = sign_extend32(((be16_to_cpu(data->be16) >> 4) & 0xff0) |
-				  (be16_to_cpu(data->be16) & 0xf), 11);
 
-	ret = regmap_bulk_read(data->regmap, BME280_REG_COMP_H5,
-			       &data->le16, sizeof(data->le16));
-	if (ret) {
-		dev_err(dev, "failed to read H5 comp value\n");
-		return ret;
-	}
-	calib->H5 = sign_extend32(FIELD_GET(BME280_COMP_H5_MASK, le16_to_cpu(data->le16)), 11);
-
-	ret = regmap_read(data->regmap, BME280_REG_COMP_H6, &tmp);
-	if (ret) {
-		dev_err(dev, "failed to read H6 comp value\n");
-		return ret;
-	}
-	calib->H6 = sign_extend32(tmp, 7);
+	calib->H2 = get_unaligned_le16(&data->bme280_humid_cal_buf[H2]);
+	calib->H3 = data->bme280_humid_cal_buf[H3];
+	tmp_1 = get_unaligned_be16(&data->bme280_humid_cal_buf[H4]);
+	tmp_2 = FIELD_GET(BME280_COMP_H4_GET_MASK_UP, tmp_1);
+	h4_upper = FIELD_PREP(BME280_COMP_H4_PREP_MASK_UP, tmp_2);
+	h4_lower = FIELD_GET(BME280_COMP_H4_MASK_LOW,
+			get_unaligned_be16(&data->bme280_humid_cal_buf[H4]));
+	calib->H4 = sign_extend32(h4_upper | h4_lower, 11);
+	calib->H5 = sign_extend32(FIELD_GET(BME280_COMP_H5_MASK,
+			get_unaligned_le16(&data->bme280_humid_cal_buf[H5])), 11);
+	calib->H6 = data->bme280_humid_cal_buf[H6];
 
 	return 0;
 }
diff --git a/drivers/iio/pressure/bmp280.h b/drivers/iio/pressure/bmp280.h
index a853b6d5bdfa..4e675401d61b 100644
--- a/drivers/iio/pressure/bmp280.h
+++ b/drivers/iio/pressure/bmp280.h
@@ -257,8 +257,13 @@ 
 #define BME280_REG_COMP_H5		0xE5
 #define BME280_REG_COMP_H6		0xE7
 
+#define BME280_COMP_H4_GET_MASK_UP	GENMASK(15, 8)
+#define BME280_COMP_H4_PREP_MASK_UP	GENMASK(11, 4)
+#define BME280_COMP_H4_MASK_LOW		GENMASK(3, 0)
 #define BME280_COMP_H5_MASK		GENMASK(15, 4)
 
+#define BME280_CONTIGUOUS_CALIB_REGS	7
+
 #define BME280_OSRS_HUMIDITY_MASK	GENMASK(2, 0)
 #define BME280_OSRS_HUMIDITY_SKIP	0
 #define BME280_OSRS_HUMIDITY_1X		1
@@ -426,6 +431,7 @@  struct bmp280_data {
 		/* Calibration data buffers */
 		__le16 bmp280_cal_buf[BMP280_CONTIGUOUS_CALIB_REGS / 2];
 		__be16 bmp180_cal_buf[BMP180_REG_CALIB_COUNT / 2];
+		u8 bme280_humid_cal_buf[BME280_CONTIGUOUS_CALIB_REGS];
 		u8 bmp380_cal_buf[BMP380_CALIB_REG_COUNT];
 		/* Miscellaneous, endianness-aware data buffers */