On Thu, 5 Sep 2024 12:20:45 +0200 Emil Gedenryd <emil.gedenryd@axis.com> wrote: > The opt3001 driver uses predetermined full-scale range values to > determine what exponent to use for event trigger threshold values. > The problem is that one of the values specified in the datasheet is > missing from the implementation, causing a big gap in settable values. > > Add missing full-scale range array value. > > Signed-off-by: Emil Gedenryd <emil.gedenryd@axis.com> I assume this has more of an impact in that if you write values beyond this one the index will be off by one and the value written to the register will be incorrect? Please clarify if that is the case and also add a fixes tag to the commit that introduced this bug. Thanks, Jonathan > --- > drivers/iio/light/opt3001.c | 4 ++++ > 1 file changed, 4 insertions(+) > > diff --git a/drivers/iio/light/opt3001.c b/drivers/iio/light/opt3001.c > index 887c4b776a86..176e54bb48c3 100644 > --- a/drivers/iio/light/opt3001.c > +++ b/drivers/iio/light/opt3001.c > @@ -138,6 +138,10 @@ static const struct opt3001_scale opt3001_scales[] = { > .val = 20966, > .val2 = 400000, > }, > + { > + .val = 41932, > + .val2 = 800000, > + }, > { > .val = 83865, > .val2 = 600000, >
On Sat, 2024-09-07 at 18:28 +0100, Jonathan Cameron wrote: > On Thu, 5 Sep 2024 12:20:45 +0200 > Emil Gedenryd <emil.gedenryd@axis.com> wrote: > > > The opt3001 driver uses predetermined full-scale range values to > > determine what exponent to use for event trigger threshold values. > > The problem is that one of the values specified in the datasheet is > > missing from the implementation, causing a big gap in settable values. > > > > Add missing full-scale range array value. > > > > Signed-off-by: Emil Gedenryd <emil.gedenryd@axis.com> > I assume this has more of an impact in that if you write values beyond this one > the index will be off by one and the value written to the register > will be incorrect? > > Please clarify if that is the case and also add a fixes tag > to the commit that introduced this bug. > > Thanks, > > Jonathan Hi Jonathan, You are correct regarding the behaviour. Thanks for the suggestion on how to clarify the message, I'll update it as well as add a fixes tag when I submit a new version either later today or tomorrow. Best regards, Emil > > > --- > > drivers/iio/light/opt3001.c | 4 ++++ > > 1 file changed, 4 insertions(+) > > > > diff --git a/drivers/iio/light/opt3001.c b/drivers/iio/light/opt3001.c > > index 887c4b776a86..176e54bb48c3 100644 > > --- a/drivers/iio/light/opt3001.c > > +++ b/drivers/iio/light/opt3001.c > > @@ -138,6 +138,10 @@ static const struct opt3001_scale opt3001_scales[] = { > > .val = 20966, > > .val2 = 400000, > > }, > > + { > > + .val = 41932, > > + .val2 = 800000, > > + }, > > { > > .val = 83865, > > .val2 = 600000, > > >
diff --git a/drivers/iio/light/opt3001.c b/drivers/iio/light/opt3001.c index 887c4b776a86..176e54bb48c3 100644 --- a/drivers/iio/light/opt3001.c +++ b/drivers/iio/light/opt3001.c @@ -138,6 +138,10 @@ static const struct opt3001_scale opt3001_scales[] = { .val = 20966, .val2 = 400000, }, + { + .val = 41932, + .val2 = 800000, + }, { .val = 83865, .val2 = 600000,
The opt3001 driver uses predetermined full-scale range values to determine what exponent to use for event trigger threshold values. The problem is that one of the values specified in the datasheet is missing from the implementation, causing a big gap in settable values. Add missing full-scale range array value. Signed-off-by: Emil Gedenryd <emil.gedenryd@axis.com> --- drivers/iio/light/opt3001.c | 4 ++++ 1 file changed, 4 insertions(+)