Commit Message

Daniel Lezcano June 21, 2019, 1:23 p.m. UTC
The cpufreq_cooling_unregister() function uses now the policy to
unregister itself. The only purpose of the cooling device pointer is
to unregister the cpu cooling device.

As there is no more need of this pointer, remove it.

Signed-off-by: Daniel Lezcano <daniel.lezcano@linaro.org>
---
 drivers/thermal/imx_thermal.c | 8 ++++----
 1 file changed, 4 insertions(+), 4 deletions(-)

Comments

Viresh Kumar June 24, 2019, 6:06 a.m. UTC | #1
On 21-06-19, 15:23, Daniel Lezcano wrote:
> The cpufreq_cooling_unregister() function uses now the policy to
> unregister itself. The only purpose of the cooling device pointer is
> to unregister the cpu cooling device.
> 
> As there is no more need of this pointer, remove it.
> 
> Signed-off-by: Daniel Lezcano <daniel.lezcano@linaro.org>
> ---
>  drivers/thermal/imx_thermal.c | 8 ++++----
>  1 file changed, 4 insertions(+), 4 deletions(-)
> 
> diff --git a/drivers/thermal/imx_thermal.c b/drivers/thermal/imx_thermal.c
> index 6746f1b73eb7..021c0948b740 100644
> --- a/drivers/thermal/imx_thermal.c
> +++ b/drivers/thermal/imx_thermal.c
> @@ -203,7 +203,6 @@ static struct thermal_soc_data thermal_imx7d_data = {
>  struct imx_thermal_data {
>  	struct cpufreq_policy *policy;
>  	struct thermal_zone_device *tz;
> -	struct thermal_cooling_device *cdev;
>  	enum thermal_device_mode mode;
>  	struct regmap *tempmon;
>  	u32 c1, c2; /* See formula in imx_init_calib() */
> @@ -656,6 +655,7 @@ MODULE_DEVICE_TABLE(of, of_imx_thermal_match);
>  static int imx_thermal_register_legacy_cooling(struct imx_thermal_data *data)
>  {
>  	struct device_node *np;
> +	struct thermal_cooling_device *cdev;
>  	int ret;
>  
>  	data->policy = cpufreq_cpu_get(0);
> @@ -667,9 +667,9 @@ static int imx_thermal_register_legacy_cooling(struct imx_thermal_data *data)
>  	np = of_get_cpu_node(data->policy->cpu, NULL);
>  
>  	if (!np || !of_find_property(np, "#cooling-cells", NULL)) {
> -		data->cdev = cpufreq_cooling_register(data->policy);
> -		if (IS_ERR(data->cdev)) {
> -			ret = PTR_ERR(data->cdev);
> +		cdev = cpufreq_cooling_register(data->policy);
> +		if (IS_ERR(cdev)) {
> +			ret = PTR_ERR(cdev);
>  			cpufreq_cpu_put(data->policy);
>  			return ret;
>  		}

This too..

Acked-by: Viresh Kumar <viresh.kumar@linaro.org>
diff mbox series

Patch

diff --git a/drivers/thermal/imx_thermal.c b/drivers/thermal/imx_thermal.c
index 6746f1b73eb7..021c0948b740 100644
--- a/drivers/thermal/imx_thermal.c
+++ b/drivers/thermal/imx_thermal.c
@@ -203,7 +203,6 @@  static struct thermal_soc_data thermal_imx7d_data = {
 struct imx_thermal_data {
 	struct cpufreq_policy *policy;
 	struct thermal_zone_device *tz;
-	struct thermal_cooling_device *cdev;
 	enum thermal_device_mode mode;
 	struct regmap *tempmon;
 	u32 c1, c2; /* See formula in imx_init_calib() */
@@ -656,6 +655,7 @@  MODULE_DEVICE_TABLE(of, of_imx_thermal_match);
 static int imx_thermal_register_legacy_cooling(struct imx_thermal_data *data)
 {
 	struct device_node *np;
+	struct thermal_cooling_device *cdev;
 	int ret;
 
 	data->policy = cpufreq_cpu_get(0);
@@ -667,9 +667,9 @@  static int imx_thermal_register_legacy_cooling(struct imx_thermal_data *data)
 	np = of_get_cpu_node(data->policy->cpu, NULL);
 
 	if (!np || !of_find_property(np, "#cooling-cells", NULL)) {
-		data->cdev = cpufreq_cooling_register(data->policy);
-		if (IS_ERR(data->cdev)) {
-			ret = PTR_ERR(data->cdev);
+		cdev = cpufreq_cooling_register(data->policy);
+		if (IS_ERR(cdev)) {
+			ret = PTR_ERR(cdev);
 			cpufreq_cpu_put(data->policy);
 			return ret;
 		}