diff mbox series

[V4,3/3] thermal/drivers/cpu_cooling: cpufreq_cooling_register returns an int

Message ID 20190627210209.32600-3-daniel.lezcano@linaro.org (mailing list archive)
State New, archived
Headers show
Series None | expand

Commit Message

Daniel Lezcano June 27, 2019, 9:02 p.m. UTC
It looks like after the changes in the patch the only reason for
returning (struct thermal_cooling_device *) from
cpufreq_cooling_register() is error checking, but it would be much
more straightforward to return int for this purpose.

Moreover, that would prevent the callers of it from doing incorrect
things with the returned pointers (like using it to unregister the
cooling device).

Replace the returned value an integer instead of a pointer to a
thermal cooling device structure.

Suggested-by: Rafael J. Wysocki <rafael@kernel.org>
Signed-off-by: Daniel Lezcano <daniel.lezcano@linaro.org>
---
 drivers/thermal/cpu_cooling.c                 | 63 +++++++++----------
 drivers/thermal/imx_thermal.c                 |  6 +-
 .../ti-soc-thermal/ti-thermal-common.c        |  7 +--
 include/linux/cpu_cooling.h                   | 16 ++---
 4 files changed, 40 insertions(+), 52 deletions(-)

Comments

Viresh Kumar June 28, 2019, 6:01 a.m. UTC | #1
On 27-06-19, 23:02, Daniel Lezcano wrote:
> It looks like after the changes in the patch the only reason for
> returning (struct thermal_cooling_device *) from
> cpufreq_cooling_register() is error checking, but it would be much
> more straightforward to return int for this purpose.
> 
> Moreover, that would prevent the callers of it from doing incorrect
> things with the returned pointers (like using it to unregister the
> cooling device).
> 
> Replace the returned value an integer instead of a pointer to a
> thermal cooling device structure.
> 
> Suggested-by: Rafael J. Wysocki <rafael@kernel.org>
> Signed-off-by: Daniel Lezcano <daniel.lezcano@linaro.org>
> ---
>  drivers/thermal/cpu_cooling.c                 | 63 +++++++++----------
>  drivers/thermal/imx_thermal.c                 |  6 +-
>  .../ti-soc-thermal/ti-thermal-common.c        |  7 +--
>  include/linux/cpu_cooling.h                   | 16 ++---
>  4 files changed, 40 insertions(+), 52 deletions(-)

Acked-by: Viresh Kumar <viresh.kumar@linaro.org>
diff mbox series

Patch

diff --git a/drivers/thermal/cpu_cooling.c b/drivers/thermal/cpu_cooling.c
index be01546a656f..0d5e39716542 100644
--- a/drivers/thermal/cpu_cooling.c
+++ b/drivers/thermal/cpu_cooling.c
@@ -530,13 +530,12 @@  static struct notifier_block thermal_cpufreq_notifier_block = {
  * cooling devices. It also gives the opportunity to link the cooling device
  * with a device tree node, in order to bind it via the thermal DT code.
  *
- * Return: a valid struct thermal_cooling_device pointer on success,
- * on failure, it returns a corresponding ERR_PTR().
+ * Return: zero on success, less than zero corresponding to the
+ * negative error code.
  */
-static struct thermal_cooling_device *
-__cpufreq_cooling_register(struct device_node *np,
-			struct cpufreq_policy *policy,
-			struct em_perf_domain *em)
+static int __cpufreq_cooling_register(struct device_node *np,
+				      struct cpufreq_policy *policy,
+				      struct em_perf_domain *em)
 {
 	struct thermal_cooling_device *cdev;
 	struct cpufreq_cooling_device *cpufreq_cdev;
@@ -548,19 +547,19 @@  __cpufreq_cooling_register(struct device_node *np,
 
 	if (IS_ERR_OR_NULL(policy)) {
 		pr_err("%s: cpufreq policy isn't valid: %p\n", __func__, policy);
-		return ERR_PTR(-EINVAL);
+		return -EINVAL;
 	}
 
 	i = cpufreq_table_count_valid_entries(policy);
 	if (!i) {
 		pr_debug("%s: CPUFreq table not found or has no valid entries\n",
 			 __func__);
-		return ERR_PTR(-ENODEV);
+		return -ENODEV;
 	}
 
 	cpufreq_cdev = kzalloc(sizeof(*cpufreq_cdev), GFP_KERNEL);
 	if (!cpufreq_cdev)
-		return ERR_PTR(-ENOMEM);
+		return -ENOMEM;
 
 	cpufreq_cdev->policy = policy;
 	num_cpus = cpumask_weight(policy->related_cpus);
@@ -568,7 +567,7 @@  __cpufreq_cooling_register(struct device_node *np,
 					 sizeof(*cpufreq_cdev->idle_time),
 					 GFP_KERNEL);
 	if (!cpufreq_cdev->idle_time) {
-		cdev = ERR_PTR(-ENOMEM);
+		ret = -ENOMEM;
 		goto free_cdev;
 	}
 
@@ -576,10 +575,8 @@  __cpufreq_cooling_register(struct device_node *np,
 	cpufreq_cdev->max_level = i - 1;
 
 	ret = ida_simple_get(&cpufreq_ida, 0, 0, GFP_KERNEL);
-	if (ret < 0) {
-		cdev = ERR_PTR(ret);
+	if (ret < 0)
 		goto free_idle_time;
-	}
 	cpufreq_cdev->id = ret;
 
 	snprintf(dev_name, sizeof(dev_name), "thermal-cpufreq-%d",
@@ -597,14 +594,16 @@  __cpufreq_cooling_register(struct device_node *np,
 	if (policy->freq_table_sorted == CPUFREQ_TABLE_UNSORTED) {
 		pr_err("%s: unsorted frequency tables are not supported\n",
 				__func__);
-		cdev = ERR_PTR(-EINVAL);
+		ret = -EINVAL;
 		goto remove_ida;
 	}
 
 	cdev = thermal_of_cooling_device_register(np, dev_name, cpufreq_cdev,
 						  cooling_ops);
-	if (IS_ERR(cdev))
+	if (IS_ERR(cdev)) {
+		ret = PTR_ERR(cdev);
 		goto remove_ida;
+	}
 
 	cpufreq_cdev->clipped_freq = get_state_freq(cpufreq_cdev, 0);
 	cpufreq_cdev->cdev = cdev;
@@ -619,7 +618,7 @@  __cpufreq_cooling_register(struct device_node *np,
 		cpufreq_register_notifier(&thermal_cpufreq_notifier_block,
 					  CPUFREQ_POLICY_NOTIFIER);
 
-	return cdev;
+	return 0;
 
 remove_ida:
 	ida_simple_remove(&cpufreq_ida, cpufreq_cdev->id);
@@ -627,7 +626,7 @@  __cpufreq_cooling_register(struct device_node *np,
 	kfree(cpufreq_cdev->idle_time);
 free_cdev:
 	kfree(cpufreq_cdev);
-	return cdev;
+	return ret;
 }
 
 /**
@@ -638,11 +637,10 @@  __cpufreq_cooling_register(struct device_node *np,
  * "thermal-cpufreq-%x". This api can support multiple instances of cpufreq
  * cooling devices.
  *
- * Return: a valid struct thermal_cooling_device pointer on success,
- * on failure, it returns a corresponding ERR_PTR().
+ * Return: zero on success, less than zero corresponding to the
+ * negative error code.
  */
-struct thermal_cooling_device *
-cpufreq_cooling_register(struct cpufreq_policy *policy)
+int cpufreq_cooling_register(struct cpufreq_policy *policy)
 {
 	return __cpufreq_cooling_register(NULL, policy, NULL);
 }
@@ -664,34 +662,31 @@  EXPORT_SYMBOL_GPL(cpufreq_cooling_register);
  * It also takes into account, if property present in policy CPU node, the
  * static power consumed by the cpu.
  *
- * Return: a valid struct thermal_cooling_device pointer on success,
- * and NULL on failure.
+ * Return: zero on success, less than zero corresponding to the
+ * negative error code.
  */
-struct thermal_cooling_device *
-of_cpufreq_cooling_register(struct cpufreq_policy *policy)
+int of_cpufreq_cooling_register(struct cpufreq_policy *policy)
 {
 	struct device_node *np = of_get_cpu_node(policy->cpu, NULL);
-	struct thermal_cooling_device *cdev = NULL;
+	int ret = -EINVAL;
 
 	if (!np) {
 		pr_err("cpu_cooling: OF node not available for cpu%d\n",
 		       policy->cpu);
-		return NULL;
+		return -EINVAL;
 	}
 
 	if (of_find_property(np, "#cooling-cells", NULL)) {
 		struct em_perf_domain *em = em_cpu_get(policy->cpu);
 
-		cdev = __cpufreq_cooling_register(np, policy, em);
-		if (IS_ERR(cdev)) {
-			pr_err("cpu_cooling: cpu%d failed to register as cooling device: %ld\n",
-			       policy->cpu, PTR_ERR(cdev));
-			cdev = NULL;
-		}
+		ret = __cpufreq_cooling_register(np, policy, em);
+		if (ret)
+			pr_err("cpu_cooling: cpu%d failed to register as cooling device: %d\n",
+			       policy->cpu, ret);
 	}
 
 	of_node_put(np);
-	return cdev;
+	return ret;
 }
 EXPORT_SYMBOL_GPL(of_cpufreq_cooling_register);
 
diff --git a/drivers/thermal/imx_thermal.c b/drivers/thermal/imx_thermal.c
index 021c0948b740..1c4b49b583bc 100644
--- a/drivers/thermal/imx_thermal.c
+++ b/drivers/thermal/imx_thermal.c
@@ -655,7 +655,6 @@  MODULE_DEVICE_TABLE(of, of_imx_thermal_match);
 static int imx_thermal_register_legacy_cooling(struct imx_thermal_data *data)
 {
 	struct device_node *np;
-	struct thermal_cooling_device *cdev;
 	int ret;
 
 	data->policy = cpufreq_cpu_get(0);
@@ -667,9 +666,8 @@  static int imx_thermal_register_legacy_cooling(struct imx_thermal_data *data)
 	np = of_get_cpu_node(data->policy->cpu, NULL);
 
 	if (!np || !of_find_property(np, "#cooling-cells", NULL)) {
-		cdev = cpufreq_cooling_register(data->policy);
-		if (IS_ERR(cdev)) {
-			ret = PTR_ERR(cdev);
+		ret = cpufreq_cooling_register(data->policy);
+		if (ret) {
 			cpufreq_cpu_put(data->policy);
 			return ret;
 		}
diff --git a/drivers/thermal/ti-soc-thermal/ti-thermal-common.c b/drivers/thermal/ti-soc-thermal/ti-thermal-common.c
index 170b70b6ec61..eacc46d7bd1c 100644
--- a/drivers/thermal/ti-soc-thermal/ti-thermal-common.c
+++ b/drivers/thermal/ti-soc-thermal/ti-thermal-common.c
@@ -232,7 +232,7 @@  int ti_thermal_register_cpu_cooling(struct ti_bandgap *bgp, int id)
 {
 	struct ti_thermal_data *data;
 	struct device_node *np = bgp->dev->of_node;
-	struct thermal_cooling_device *cdev;
+	int ret;
 
 	/*
 	 * We are assuming here that if one deploys the zone
@@ -256,9 +256,8 @@  int ti_thermal_register_cpu_cooling(struct ti_bandgap *bgp, int id)
 	}
 
 	/* Register cooling device */
-	cdev = cpufreq_cooling_register(data->policy);
-	if (IS_ERR(cdev)) {
-		int ret = PTR_ERR(cdev);
+	ret = cpufreq_cooling_register(data->policy);
+	if (ret) {
 		dev_err(bgp->dev, "Failed to register cpu cooling device %d\n",
 			ret);
 		cpufreq_cpu_put(data->policy);
diff --git a/include/linux/cpu_cooling.h b/include/linux/cpu_cooling.h
index 89f469ee4be4..98f7c8a9cab6 100644
--- a/include/linux/cpu_cooling.h
+++ b/include/linux/cpu_cooling.h
@@ -24,8 +24,7 @@  struct cpufreq_policy;
  * cpufreq_cooling_register - function to create cpufreq cooling device.
  * @policy: cpufreq policy.
  */
-struct thermal_cooling_device *
-cpufreq_cooling_register(struct cpufreq_policy *policy);
+int cpufreq_cooling_register(struct cpufreq_policy *policy);
 
 /**
  * cpufreq_cooling_unregister - function to remove cpufreq cooling device.
@@ -34,10 +33,9 @@  cpufreq_cooling_register(struct cpufreq_policy *policy);
 void cpufreq_cooling_unregister(struct cpufreq_policy *policy);
 
 #else /* !CONFIG_CPU_THERMAL */
-static inline struct thermal_cooling_device *
-cpufreq_cooling_register(struct cpufreq_policy *policy)
+static inline int cpufreq_cooling_register(struct cpufreq_policy *policy)
 {
-	return ERR_PTR(-ENOSYS);
+	return -ENOSYS;
 }
 
 static inline
@@ -52,13 +50,11 @@  void cpufreq_cooling_unregister(struct cpufreq_policy *policy)
  * of_cpufreq_cooling_register - create cpufreq cooling device based on DT.
  * @policy: cpufreq policy.
  */
-struct thermal_cooling_device *
-of_cpufreq_cooling_register(struct cpufreq_policy *policy);
+int of_cpufreq_cooling_register(struct cpufreq_policy *policy);
 #else
-static inline struct thermal_cooling_device *
-of_cpufreq_cooling_register(struct cpufreq_policy *policy)
+static inline int of_cpufreq_cooling_register(struct cpufreq_policy *policy)
 {
-	return NULL;
+	return -ENOSYS;
 }
 #endif /* defined(CONFIG_THERMAL_OF) && defined(CONFIG_CPU_THERMAL) */