diff mbox series

msi2500: assign SPI bus number dynamically

Message ID 20190817011210.29765-1-crope@iki.fi (mailing list archive)
State New, archived
Headers show
Series msi2500: assign SPI bus number dynamically | expand

Commit Message

Antti Palosaari Aug. 17, 2019, 1:12 a.m. UTC
SPI bus number must be assigned dynamically for each device, otherwise it
will crash when multiple devices are plugged to system.

Cc: stable@vger.kernel.org
Reported-and-tested-by: syzbot+c60ddb60b685777d9d59@syzkaller.appspotmail.com
Signed-off-by: Antti Palosaari <crope@iki.fi>
---
 drivers/media/usb/msi2500/msi2500.c | 2 +-
 1 file changed, 1 insertion(+), 1 deletion(-)
diff mbox series

Patch

diff --git a/drivers/media/usb/msi2500/msi2500.c b/drivers/media/usb/msi2500/msi2500.c
index 65be6f140fe8..1c60dfb647e5 100644
--- a/drivers/media/usb/msi2500/msi2500.c
+++ b/drivers/media/usb/msi2500/msi2500.c
@@ -1230,7 +1230,7 @@  static int msi2500_probe(struct usb_interface *intf,
 	}
 
 	dev->master = master;
-	master->bus_num = 0;
+	master->bus_num = -1;
 	master->num_chipselect = 1;
 	master->transfer_one_message = msi2500_transfer_one_message;
 	spi_master_set_devdata(master, dev);