Naohiro Aota Aug. 23, 2019, 10:10 a.m. UTC
Supporting the RAID5/6 profile in HMZONED mode is not trivial. For example,
non-full stripe writes will cause overwriting parity blocks. When we do a
non-full stripe write, it writes to the parity block with the data at that
moment. Then, another write to the stripes will try to overwrite the parity
block with new parity value. However, sequential zones do not allow such
parity overwriting.

Furthermore, using RAID5/6 on SMR drives, which usually have a huge
capacity, incur large overhead of rebuild. Such overhead can lead to higher
to higher volume failure rate (e.g. additional drive failure during
rebuild) because of the increased rebuild time.

Thus, let's disable RAID5/6 profile in HMZONED mode for now.

Signed-off-by: Naohiro Aota <naohiro.aota@wdc.com>
---
 fs/btrfs/hmzoned.c | 7 +++++++
 1 file changed, 7 insertions(+)

Comments

Johannes Thumshirn Aug. 23, 2019, 12:09 p.m. UTC | #1
Looks good,
Reviewed-by: Johannes Thumshirn <jthumshirn@suse.de>

Patch
diff mbox series

diff --git a/fs/btrfs/hmzoned.c b/fs/btrfs/hmzoned.c
index ca58eee08a70..84b7b561840d 100644
--- a/fs/btrfs/hmzoned.c
+++ b/fs/btrfs/hmzoned.c
@@ -219,6 +219,13 @@  int btrfs_check_hmzoned_mode(struct btrfs_fs_info *fs_info)
 		goto out;
 	}
 
+	/* RAID56 is not allowed */
+	if (btrfs_fs_incompat(fs_info, RAID56)) {
+		btrfs_err(fs_info, "HMZONED mode does not support RAID56");
+		ret = -EINVAL;
+		goto out;
+	}
+
 	btrfs_info(fs_info, "HMZONED mode enabled, zone size %llu B",
 		   fs_info->zone_size);
 out: