diff mbox series

[1/2] power: supply: cpcap-battery: Check voltage before orderly_poweroff

Message ID 20191016223005.9246-2-tony@atomide.com (mailing list archive)
State Superseded, archived
Headers show
Series cpcap charger and battery fixes | expand

Commit Message

Tony Lindgren Oct. 16, 2019, 10:30 p.m. UTC
We can get the low voltage interrupt trigger sometimes way too early,
maybe because of CPU load spikes. This causes orderly_poweroff() be
called too easily.

Let's check the voltage before orderly_poweroff in case it was not
yet a permanent condition. We will be getting more interrupts anyways
if the condition persists.

Let's also show the measured voltages for low battery and battery
empty warnings since we have them.

Cc: Merlijn Wajer <merlijn@wizzup.org>
Cc: Pavel Machek <pavel@ucw.cz>
Signed-off-by: Tony Lindgren <tony@atomide.com>
---
 drivers/power/supply/cpcap-battery.c | 8 +++++---
 1 file changed, 5 insertions(+), 3 deletions(-)
diff mbox series

Patch

diff --git a/drivers/power/supply/cpcap-battery.c b/drivers/power/supply/cpcap-battery.c
--- a/drivers/power/supply/cpcap-battery.c
+++ b/drivers/power/supply/cpcap-battery.c
@@ -562,12 +562,14 @@  static irqreturn_t cpcap_battery_irq_thread(int irq, void *data)
 	switch (d->action) {
 	case CPCAP_BATTERY_IRQ_ACTION_BATTERY_LOW:
 		if (latest->current_ua >= 0)
-			dev_warn(ddata->dev, "Battery low at 3.3V!\n");
+			dev_warn(ddata->dev, "Battery low at %imV!\n",
+				latest->voltage / 1000);
 		break;
 	case CPCAP_BATTERY_IRQ_ACTION_POWEROFF:
-		if (latest->current_ua >= 0) {
+		if (latest->current_ua >= 0 && latest->voltage <= 3200000) {
 			dev_emerg(ddata->dev,
-				  "Battery empty at 3.1V, powering off\n");
+				  "Battery empty at %imV, powering off\n",
+				  latest->voltage / 1000);
 			orderly_poweroff(true);
 		}
 		break;