@@ -128,6 +128,37 @@
};
};
+ thermal-zones {
+ core-cluster {
+ polling-delay-passive = <1000>;
+ polling-delay = <5000>;
+ thermal-sensors = <&tmu 0>;
+
+ trips {
+ core_cluster_alert: core-cluster-alert {
+ temperature = <85000>;
+ hysteresis = <2000>;
+ type = "passive";
+ };
+
+ core_cluster_crit: core-cluster-crit {
+ temperature = <95000>;
+ hysteresis = <2000>;
+ type = "critical";
+ };
+ };
+
+ cooling-maps {
+ map0 {
+ trip = <&core_cluster_alert>;
+ cooling-device =
+ <&cpu0 THERMAL_NO_LIMIT THERMAL_NO_LIMIT>,
+ <&cpu1 THERMAL_NO_LIMIT THERMAL_NO_LIMIT>;
+ };
+ };
+ };
+ };
+
soc: soc {
compatible = "simple-bus";
#address-cells = <2>;
@@ -580,37 +611,6 @@
#thermal-sensor-cells = <1>;
};
- thermal-zones {
- core-cluster {
- polling-delay-passive = <1000>;
- polling-delay = <5000>;
- thermal-sensors = <&tmu 0>;
-
- trips {
- core_cluster_alert: core-cluster-alert {
- temperature = <85000>;
- hysteresis = <2000>;
- type = "passive";
- };
-
- core_cluster_crit: core-cluster-crit {
- temperature = <95000>;
- hysteresis = <2000>;
- type = "critical";
- };
- };
-
- cooling-maps {
- map0 {
- trip = <&core_cluster_alert>;
- cooling-device =
- <&cpu0 THERMAL_NO_LIMIT THERMAL_NO_LIMIT>,
- <&cpu1 THERMAL_NO_LIMIT THERMAL_NO_LIMIT>;
- };
- };
- };
- };
-
pcie@1f0000000 { /* Integrated Endpoint Root Complex */
compatible = "pci-host-ecam-generic";
reg = <0x01 0xf0000000 0x0 0x100000>;
Move thermal-zone node from the soc node to the root node. thermal-zone node does not have any register properties and thus shouldn't be placed on the bus. This fixes the following build warnings with W=1: arch/arm64/boot/dts/freescale/fsl-ls1028a.dtsi:583.17-612.5: Warning (simple_bus_reg): /soc/thermal-zones: missing or empty reg/ranges property Signed-off-by: Fabio Estevam <festevam@gmail.com> --- .../arm64/boot/dts/freescale/fsl-ls1028a.dtsi | 62 +++++++++---------- 1 file changed, 31 insertions(+), 31 deletions(-)