diff mbox series

[v4,2/2] arm64: dts: allwinner: h6: Add thermal trip points/cooling map

Message ID 20200420124634.32726-3-peron.clem@gmail.com (mailing list archive)
State New, archived
Headers show
Series Add support for Allwinner H6 DVFS | expand

Commit Message

Clément Péron April 20, 2020, 12:46 p.m. UTC
From: Ondrej Jirman <megous@megous.com>

This enables passive cooling by down-regulating CPU voltage
and frequency.

Signed-off-by: Ondrej Jirman <megous@megous.com>
Signed-off-by: Clément Péron <peron.clem@gmail.com>
---
 arch/arm64/boot/dts/allwinner/sun50i-h6.dtsi | 24 ++++++++++++++++++++
 1 file changed, 24 insertions(+)
diff mbox series

Patch

diff --git a/arch/arm64/boot/dts/allwinner/sun50i-h6.dtsi b/arch/arm64/boot/dts/allwinner/sun50i-h6.dtsi
index 370e77b86fe1..60da1627772b 100644
--- a/arch/arm64/boot/dts/allwinner/sun50i-h6.dtsi
+++ b/arch/arm64/boot/dts/allwinner/sun50i-h6.dtsi
@@ -964,6 +964,30 @@ 
 			polling-delay-passive = <0>;
 			polling-delay = <0>;
 			thermal-sensors = <&ths 0>;
+
+			trips {
+				cpu_alert: cpu-alert {
+					temperature = <85000>;
+					hysteresis = <2000>;
+					type = "passive";
+				};
+
+				cpu-crit {
+					temperature = <100000>;
+					hysteresis = <0>;
+					type = "critical";
+				};
+			};
+
+			cooling-maps {
+				map0 {
+					trip = <&cpu_alert>;
+					cooling-device = <&cpu0 THERMAL_NO_LIMIT THERMAL_NO_LIMIT>,
+							 <&cpu1 THERMAL_NO_LIMIT THERMAL_NO_LIMIT>,
+							 <&cpu2 THERMAL_NO_LIMIT THERMAL_NO_LIMIT>,
+							 <&cpu3 THERMAL_NO_LIMIT THERMAL_NO_LIMIT>;
+				};
+			};
 		};
 
 		gpu-thermal {