@@ -15,6 +15,7 @@ power/power-domain.yaml. It provides the power domains defined in
- include/dt-bindings/power/mt2701-power.h
- include/dt-bindings/power/mt2712-power.h
- include/dt-bindings/power/mt7622-power.h
+- include/dt-bindings/power/mt8183-power.h
Required properties:
- compatible: Should be one of:
@@ -27,12 +28,16 @@ Required properties:
- "mediatek,mt7623a-scpsys": For MT7623A SoC
- "mediatek,mt7629-scpsys", "mediatek,mt7622-scpsys": For MT7629 SoC
- "mediatek,mt8173-scpsys"
+ - "mediatek,mt8183-scpsys"
- #power-domain-cells: Must be 1
- reg: Address range of the SCPSYS unit
- infracfg: must contain a phandle to the infracfg controller
-- clock, clock-names: clocks according to the common clock binding.
- These are clocks which hardware needs to be
- enabled before enabling certain power domains.
+- clock, clock-names: Clocks according to the common clock binding.
+ Some SoCs have to groups of clocks.
+ BASIC clocks need to be enabled before enabling the
+ corresponding power domain.
+ SUBSYS clocks need to be enabled before releasing the
+ bus protection.
Required clocks for MT2701 or MT7623: "mm", "mfg", "ethif"
Required clocks for MT2712: "mm", "mfg", "venc", "jpgdec", "audio", "vdec"
Required clocks for MT6765: MUX: "mm", "mfg"
@@ -43,6 +48,15 @@ Required properties:
Required clocks for MT7622 or MT7629: "hif_sel"
Required clocks for MT7623A: "ethif"
Required clocks for MT8173: "mm", "mfg", "venc", "venc_lt"
+ Required clocks for MT8183: BASIC: "audio", "mfg", "mm", "cam", "isp",
+ "vpu", "vpu1", "vpu2", "vpu3"
+ SUBSYS: "mm-0", "mm-1", "mm-2", "mm-3",
+ "mm-4", "mm-5", "mm-6", "mm-7",
+ "mm-8", "mm-9", "isp-0", "isp-1",
+ "cam-0", "cam-1", "cam-2", "cam-3",
+ "cam-4", "cam-5", "cam-6", "vpu-0",
+ "vpu-1", "vpu-2", "vpu-3", "vpu-4",
+ "vpu-5"
Optional properties:
- vdec-supply: Power supply for the vdec power domain
@@ -55,6 +69,7 @@ Optional properties:
- mfg_async-supply: Power supply for the mfg_async power domain
- mfg_2d-supply: Power supply for the mfg_2d power domain
- mfg-supply: Power supply for the mfg power domain
+- mediatek,smi : A phandle to the smi_common node
Example:
new file mode 100644
@@ -0,0 +1,26 @@
+/* SPDX-License-Identifier: GPL-2.0 */
+/*
+ * Copyright (c) 2020 MediaTek Inc.
+ * Author: Weiyi Lu <weiyi.lu@mediatek.com>
+ */
+
+#ifndef _DT_BINDINGS_POWER_MT8183_POWER_H
+#define _DT_BINDINGS_POWER_MT8183_POWER_H
+
+#define MT8183_POWER_DOMAIN_AUDIO 0
+#define MT8183_POWER_DOMAIN_CONN 1
+#define MT8183_POWER_DOMAIN_MFG_ASYNC 2
+#define MT8183_POWER_DOMAIN_MFG 3
+#define MT8183_POWER_DOMAIN_MFG_CORE0 4
+#define MT8183_POWER_DOMAIN_MFG_CORE1 5
+#define MT8183_POWER_DOMAIN_MFG_2D 6
+#define MT8183_POWER_DOMAIN_DISP 7
+#define MT8183_POWER_DOMAIN_CAM 8
+#define MT8183_POWER_DOMAIN_ISP 9
+#define MT8183_POWER_DOMAIN_VDEC 10
+#define MT8183_POWER_DOMAIN_VENC 11
+#define MT8183_POWER_DOMAIN_VPU_TOP 12
+#define MT8183_POWER_DOMAIN_VPU_CORE0 13
+#define MT8183_POWER_DOMAIN_VPU_CORE1 14
+
+#endif /* _DT_BINDINGS_POWER_MT8183_POWER_H */
Add power dt-bindings of MT8183 and introduces "BASIC" and "SUBSYS" clock types in binding document. The "BASIC" type is compatible to the original power control with clock name [a-z]+[0-9]*, e.g. mm, vpu1. The "SUBSYS" type is used for bus protection control with clock name [a-z]+-[0-9]+, e.g. isp-0, cam-1. And add an optional "mediatek,smi" property for phandle to smi-common node. Signed-off-by: Weiyi Lu <weiyi.lu@mediatek.com> --- .../devicetree/bindings/soc/mediatek/scpsys.txt | 21 ++++++++++++++--- include/dt-bindings/power/mt8183-power.h | 26 ++++++++++++++++++++++ 2 files changed, 44 insertions(+), 3 deletions(-) create mode 100644 include/dt-bindings/power/mt8183-power.h