diff mbox

[v6,12/18] thermal: exynos: dts: Define default thermal-zones for Exynos4

Message ID 1422015010-11918-12-git-send-email-l.majewski@samsung.com (mailing list archive)
State New, archived
Headers show

Commit Message

Lukasz Majewski Jan. 23, 2015, 12:10 p.m. UTC
Trip points corresponding to the one defined in the exynos_tmu_data.c
for Exynos4 have been included.
This thermal-zones attribute is afterwards reused for Exynos4210, Exynos4412
and Exynos5250.

Signed-off-by: Lukasz Majewski <l.majewski@samsung.com>
---
Changes for v2:
- None
Changes for v3:
- None
Changes for v4:
- None
Changes for v5:
- None
Changes for v6:
- None
---
 arch/arm/boot/dts/exynos4-cpu-thermal.dtsi | 52 ++++++++++++++++++++++++++++++
 1 file changed, 52 insertions(+)
 create mode 100644 arch/arm/boot/dts/exynos4-cpu-thermal.dtsi
diff mbox

Patch

diff --git a/arch/arm/boot/dts/exynos4-cpu-thermal.dtsi b/arch/arm/boot/dts/exynos4-cpu-thermal.dtsi
new file mode 100644
index 0000000..506600a
--- /dev/null
+++ b/arch/arm/boot/dts/exynos4-cpu-thermal.dtsi
@@ -0,0 +1,52 @@ 
+/*
+ * Device tree sources for Exynos4 thermal zone
+ *
+ * Copyright (c) 2014 Lukasz Majewski <l.majewski@samsung.com>
+ *
+ * This program is free software; you can redistribute it and/or modify
+ * it under the terms of the GNU General Public License version 2 as
+ * published by the Free Software Foundation.
+ *
+ */
+
+#include <dt-bindings/thermal/thermal.h>
+
+/ {
+  thermal-zones {
+	cpu_thermal: cpu-thermal {
+		thermal-sensors = <&tmu 0>;
+		polling-delay-passive = <0>;
+		polling-delay = <0>;
+		trips {
+			cpu_alert0: cpu-alert-0 {
+				temperature = <70000>; /* millicelsius */
+				hysteresis = <10000>; /* millicelsius */
+				type = "active";
+			};
+			cpu_alert1: cpu-alert-1 {
+				temperature = <95000>; /* millicelsius */
+				hysteresis = <10000>; /* millicelsius */
+				type = "active";
+			};
+			cpu_alert2: cpu-alert-2 {
+				temperature = <110000>; /* millicelsius */
+				hysteresis = <10000>; /* millicelsius */
+				type = "active";
+			};
+			cpu_crit0: cpu-crit-0 {
+				temperature = <120000>; /* millicelsius */
+				hysteresis = <0>; /* millicelsius */
+				type = "critical";
+			};
+		};
+		cooling-maps {
+			map0 {
+			    trip = <&cpu_alert0>;
+			};
+			map1 {
+			    trip = <&cpu_alert1>;
+			};
+		};
+	};
+  };
+};