@@ -138,6 +138,31 @@ Properties string Type
"2M"
"Coded"
+ uint32 MinInterval [Experimental]
+
+ Minimum advertising interval to be used by the
+ advertising set, in milliseconds. Acceptable values
+ are in the range [20ms, 10,485s]. If the provided
+ MinInterval is larger than the provided MaxInterval,
+ the registration will return failure.
+
+ uint32 MaxInterval [Experimental]
+
+ Maximum advertising interval to be used by the
+ advertising set, in milliseconds. Acceptable values
+ are in the range [20ms, 10,485s]. If the provided
+ MinInterval is larger than the provided MaxInterval,
+ the registration will return failure.
+
+ int16 TxPower [Experimental]
+
+ Requested transmission power of this advertising set.
+ The provided value is used only if the "CanSetTxPower"
+ feature is enabled on the Advertising Manager. The
+ provided value must be in range [-127 to +20], where
+ units are in dBm.
+
+
LE Advertising Manager hierarchy
================================
@@ -209,3 +234,26 @@ Properties byte ActiveInstances
Possible values: "1M"
"2M"
"Coded"
+
+ dict SupportedCapabilities [Experimental]
+
+ Enumerates Advertising-related controller capabilities
+ useful to the client.
+
+ Possible Values:
+
+ byte MaxAdvLen
+
+ Max advertising data length
+
+ byte MaxScnRspLen
+
+ Max advertising scan response length
+
+ int16 MinTxPower
+
+ Min advertising tx power (dBm)
+
+ int16 MaxTxPower
+
+ Max advertising tx power (dBm)