@@ -2296,6 +2296,14 @@ static void handle_load_error(struct vdo_completion *completion)
return;
}
+ if ((completion->result == VDO_UNSUPPORTED_VERSION) &&
+ (vdo->admin.phase == LOAD_PHASE_MAKE_DIRTY)) {
+ vdo_log_error("Aborting load due to unsupported version");
+ vdo->admin.phase = LOAD_PHASE_FINISHED;
+ load_callback(completion);
+ return;
+ }
+
vdo_log_error_strerror(completion->result,
"Entering read-only mode due to load error");
vdo->admin.phase = LOAD_PHASE_WAIT_FOR_READ_ONLY;
@@ -2740,6 +2748,19 @@ static int vdo_preresume_registered(struct dm_target *ti, struct vdo *vdo)
vdo_log_info("starting device '%s'", device_name);
result = perform_admin_operation(vdo, LOAD_PHASE_START, load_callback,
handle_load_error, "load");
+ if (result == VDO_UNSUPPORTED_VERSION) {
+ /*
+ * A component version is not supported. This can happen when the
+ * recovery journal metadata is in an old version format. Abort the
+ * load without saving the state.
+ */
+ vdo->suspend_type = VDO_ADMIN_STATE_SUSPENDING;
+ perform_admin_operation(vdo, SUSPEND_PHASE_START,
+ suspend_callback, suspend_callback,
+ "suspend");
+ return result;
+ }
+
if ((result != VDO_SUCCESS) && (result != VDO_READ_ONLY)) {
/*
* Something has gone very wrong. Make sure everything has drained and
@@ -2811,7 +2832,8 @@ static int vdo_preresume(struct dm_target *ti)
vdo_register_thread_device_id(&instance_thread, &vdo->instance);
result = vdo_preresume_registered(ti, vdo);
- if ((result == VDO_PARAMETER_MISMATCH) || (result == VDO_INVALID_ADMIN_STATE))
+ if ((result == VDO_PARAMETER_MISMATCH) || (result == VDO_INVALID_ADMIN_STATE) ||
+ (result == VDO_UNSUPPORTED_VERSION))
result = -EINVAL;
vdo_unregister_thread_device_id();
return vdo_status_to_errno(result);
@@ -1574,9 +1574,7 @@ static int parse_journal_for_recovery(struct repair_completion *repair)
if (header.metadata_type == VDO_METADATA_RECOVERY_JOURNAL) {
/* This is an old format block, so we need to upgrade */
vdo_log_error_strerror(VDO_UNSUPPORTED_VERSION,
- "Recovery journal is in the old format, a read-only rebuild is required.");
- vdo_enter_read_only_mode(repair->completion.vdo,
- VDO_UNSUPPORTED_VERSION);
+ "Recovery journal is in the old format. Downgrade and complete recovery, then upgrade with a clean volume");
return VDO_UNSUPPORTED_VERSION;
}