On Wed, Jan 3, 2018 at 1:59 PM, Ognjen Galic <smclt30p@gmail.com> wrote: > The EC/ACPI firmware on Lenovo ThinkPads used to report a status > of "Unknown" when the battery is between the charge start and > charge stop thresholds. On Windows, it reports "Not Charging" > so the quirk has been added to also report correctly. > > Now the "status" attribute returns "Not Charging" when the > battery on ThinkPads is not physicaly charging. > > Signed-off-by: Ognjen Galic <smclt30p@gmail.com> Reviewed-by: Andy Shevchenko <andy.shevchenko@gmail.com> > --- > > Notes: > v7: > * Added all the style changes as suggested by Rafael > * Re-ordered the series to make this a post-implement > bugfix > > v8: > * No changes in this patch in v8 > > v9: > * No changes in this patch in v9 > > v10: > * No changes in this patch in v10 > > v11: > * Fix formatting of changelog > > v12: > * No changes in this patch in v12 > > drivers/acpi/battery.c | 22 ++++++++++++++++++++++ > 1 file changed, 22 insertions(+) > > diff --git a/drivers/acpi/battery.c b/drivers/acpi/battery.c > index 7089e31..279516e 100644 > --- a/drivers/acpi/battery.c > +++ b/drivers/acpi/battery.c > @@ -74,6 +74,7 @@ static async_cookie_t async_cookie; > static bool battery_driver_registered; > static int battery_bix_broken_package; > static int battery_notification_delay_ms; > +static int battery_quirk_notcharging; > static unsigned int cache_time = 1000; > module_param(cache_time, uint, 0644); > MODULE_PARM_DESC(cache_time, "cache time in milliseconds"); > @@ -225,6 +226,8 @@ static int acpi_battery_get_property(struct power_supply *psy, > val->intval = POWER_SUPPLY_STATUS_CHARGING; > else if (acpi_battery_is_charged(battery)) > val->intval = POWER_SUPPLY_STATUS_FULL; > + else if (battery_quirk_notcharging) > + val->intval = POWER_SUPPLY_STATUS_NOT_CHARGING; > else > val->intval = POWER_SUPPLY_STATUS_UNKNOWN; > break; > @@ -1309,6 +1312,12 @@ battery_notification_delay_quirk(const struct dmi_system_id *d) > return 0; > } > > +static int __init battery_quirk_not_charging(const struct dmi_system_id *d) > +{ > + battery_quirk_notcharging = 1; > + return 0; > +} > + > static const struct dmi_system_id bat_dmi_table[] __initconst = { > { > .callback = battery_bix_broken_package_quirk, > @@ -1326,6 +1335,19 @@ static const struct dmi_system_id bat_dmi_table[] __initconst = { > DMI_MATCH(DMI_PRODUCT_NAME, "Aspire V5-573G"), > }, > }, > + { > + /* > + * On Lenovo ThinkPads the BIOS specification defines > + * a state when the bits for charging and discharging > + * are both set to 0. That state is "Not Charging". > + */ > + .callback = battery_quirk_not_charging, > + .ident = "Lenovo ThinkPad", > + .matches = { > + DMI_MATCH(DMI_SYS_VENDOR, "LENOVO"), > + DMI_MATCH(DMI_PRODUCT_VERSION, "ThinkPad"), > + }, > + }, > {}, > }; > > -- > 2.7.4 >
diff --git a/drivers/acpi/battery.c b/drivers/acpi/battery.c index 7089e31..279516e 100644 --- a/drivers/acpi/battery.c +++ b/drivers/acpi/battery.c @@ -74,6 +74,7 @@ static async_cookie_t async_cookie; static bool battery_driver_registered; static int battery_bix_broken_package; static int battery_notification_delay_ms; +static int battery_quirk_notcharging; static unsigned int cache_time = 1000; module_param(cache_time, uint, 0644); MODULE_PARM_DESC(cache_time, "cache time in milliseconds"); @@ -225,6 +226,8 @@ static int acpi_battery_get_property(struct power_supply *psy, val->intval = POWER_SUPPLY_STATUS_CHARGING; else if (acpi_battery_is_charged(battery)) val->intval = POWER_SUPPLY_STATUS_FULL; + else if (battery_quirk_notcharging) + val->intval = POWER_SUPPLY_STATUS_NOT_CHARGING; else val->intval = POWER_SUPPLY_STATUS_UNKNOWN; break; @@ -1309,6 +1312,12 @@ battery_notification_delay_quirk(const struct dmi_system_id *d) return 0; } +static int __init battery_quirk_not_charging(const struct dmi_system_id *d) +{ + battery_quirk_notcharging = 1; + return 0; +} + static const struct dmi_system_id bat_dmi_table[] __initconst = { { .callback = battery_bix_broken_package_quirk, @@ -1326,6 +1335,19 @@ static const struct dmi_system_id bat_dmi_table[] __initconst = { DMI_MATCH(DMI_PRODUCT_NAME, "Aspire V5-573G"), }, }, + { + /* + * On Lenovo ThinkPads the BIOS specification defines + * a state when the bits for charging and discharging + * are both set to 0. That state is "Not Charging". + */ + .callback = battery_quirk_not_charging, + .ident = "Lenovo ThinkPad", + .matches = { + DMI_MATCH(DMI_SYS_VENDOR, "LENOVO"), + DMI_MATCH(DMI_PRODUCT_VERSION, "ThinkPad"), + }, + }, {}, };
The EC/ACPI firmware on Lenovo ThinkPads used to report a status of "Unknown" when the battery is between the charge start and charge stop thresholds. On Windows, it reports "Not Charging" so the quirk has been added to also report correctly. Now the "status" attribute returns "Not Charging" when the battery on ThinkPads is not physicaly charging. Signed-off-by: Ognjen Galic <smclt30p@gmail.com> --- Notes: v7: * Added all the style changes as suggested by Rafael * Re-ordered the series to make this a post-implement bugfix v8: * No changes in this patch in v8 v9: * No changes in this patch in v9 v10: * No changes in this patch in v10 v11: * Fix formatting of changelog v12: * No changes in this patch in v12 drivers/acpi/battery.c | 22 ++++++++++++++++++++++ 1 file changed, 22 insertions(+)