@@ -5,6 +5,7 @@ Required properties:
- compatible: Should be set to one of the following:
marvell,kirkwood-thermal
marvell,armadaxp-thermal
+ marvell,armada370-thermal
- reg: Device's register space.
One or two entries are expected, see the examples below.
@@ -20,12 +20,14 @@
#include <linux/kernel.h>
#include <linux/of.h>
#include <linux/module.h>
+#include <linux/delay.h>
#include <linux/platform_device.h>
#include <linux/of_device.h>
#include <linux/thermal.h>
#define MVEBU_THERMAL_SOC_VARIANT_KIRKWOOD 0x1
#define MVEBU_THERMAL_SOC_VARIANT_ARMADA_XP 0x2
+#define MVEBU_THERMAL_SOC_VARIANT_ARMADA_370 0x3
#define MVEBU_THERMAL_VALID_OFFSET 9
#define MVEBU_THERMAL_VALID_MASK 0x1
@@ -39,6 +41,7 @@
#define PMU_TDC0_REF_CAL_CNT_OFFS 11
#define PMU_TDC0_REF_CAL_CNT_MASK (0x1ff << PMU_TDC0_REF_CAL_CNT_OFFS)
#define PMU_TDC0_OTF_CAL_MASK (0x1 << 30)
+#define PMU_TDC0_START_CAL_MASK (0x1 << 25)
/* Marvell EBU Thermal Sensor Dev Structure */
struct mvebu_thermal_priv {
@@ -82,6 +85,31 @@ static void armadaxp_init_sensor(struct mvebu_thermal_priv *priv)
writel(reg, priv->sensor);
}
+static void armada370_init_sensor(struct mvebu_thermal_priv *priv)
+{
+ unsigned long reg;
+
+ if (!priv->control)
+ return;
+
+ /* ??? */
+ reg = readl_relaxed(priv->control);
+ reg |= PMU_TDC0_OTF_CAL_MASK;
+ writel(reg, priv->control);
+
+ /* Reference calibration value */
+ reg &= ~PMU_TDC0_REF_CAL_CNT_MASK;
+ reg |= (0xf1 << PMU_TDC0_REF_CAL_CNT_OFFS);
+ writel(reg, priv->control);
+
+ /* ??? */
+ reg &= ~PMU_TDC0_START_CAL_MASK;
+ writel(reg, priv->control);
+
+ /* FIXME: Why do we need this delay? */
+ mdelay(10);
+}
+
static bool mvebu_is_valid(struct mvebu_thermal_priv *priv)
{
unsigned long reg = readl_relaxed(priv->sensor);
@@ -113,6 +141,9 @@ static int mvebu_get_temp(struct thermal_zone_device *thermal,
case MVEBU_THERMAL_SOC_VARIANT_ARMADA_XP:
*temp = (3153000000UL - (10000000UL*reg)) / 13825;
break;
+ case MVEBU_THERMAL_SOC_VARIANT_ARMADA_370:
+ *temp = (228000UL - 723*reg);
+ break;
default:
*temp = 0;
break;
@@ -134,6 +165,10 @@ static const struct of_device_id mvebu_thermal_id_table[] = {
.data = (void *) MVEBU_THERMAL_SOC_VARIANT_ARMADA_XP,
},
{
+ .compatible = "marvell,armada370-thermal",
+ .data = (void *) MVEBU_THERMAL_SOC_VARIANT_ARMADA_370,
+ },
+ {
/* sentinel */
},
};
@@ -179,6 +214,10 @@ static int mvebu_thermal_probe(struct platform_device *pdev)
case MVEBU_THERMAL_SOC_VARIANT_ARMADA_XP:
priv->init_sensor = armadaxp_init_sensor;
break;
+ case MVEBU_THERMAL_SOC_VARIANT_ARMADA_370:
+ priv->is_valid = mvebu_is_valid;
+ priv->init_sensor = armada370_init_sensor;
+ break;
default:
break;
}
The Armada 370 has a register to check a valid temperature, and its own formula to obtain the temperature from the thermal sensor output register. Signed-off-by: Ezequiel Garcia <ezequiel.garcia@free-electrons.com> --- .../devicetree/bindings/thermal/mvebu-thermal.txt | 1 + drivers/thermal/mvebu_thermal.c | 39 ++++++++++++++++++++ 2 files changed, 40 insertions(+), 0 deletions(-)