@@ -704,21 +704,12 @@ static const struct factors_data sun4i_pll5_data __initconst = {
.enable = 31,
.table = &sun4i_pll5_config,
.getter = sun4i_get_pll5_factors,
- .name = "pll5",
-};
-
-static const struct factors_data sun4i_pll6_data __initconst = {
- .enable = 31,
- .table = &sun4i_pll5_config,
- .getter = sun4i_get_pll5_factors,
- .name = "pll6",
};
static const struct factors_data sun6i_a31_pll6_data __initconst = {
.enable = 31,
.table = &sun6i_a31_pll6_config,
.getter = sun6i_a31_get_pll6_factors,
- .name = "pll6x2",
};
static const struct factors_data sun5i_a13_ahb_data __initconst = {
@@ -902,6 +893,7 @@ struct gates_data {
#define SUNXI_DIVS_MAX_QTY 4
#define SUNXI_DIVISOR_WIDTH 2
+#define SUNXI_DIVS_BASE_NAME_MAX_LEN 8
struct divs_data {
const struct factors_data *factors; /* data for the factor clock */
@@ -941,7 +933,7 @@ static const struct divs_data pll5_divs_data __initconst = {
};
static const struct divs_data pll6_divs_data __initconst = {
- .factors = &sun4i_pll6_data,
+ .factors = &sun4i_pll5_data,
.ndivs = 4,
.div = {
{ .shift = 0, .table = pll6_sata_tbl, .gate = 14 }, /* M, SATA */
@@ -983,6 +975,8 @@ static void __init sunxi_divs_clk_setup(struct device_node *node,
struct clk_gate *gate = NULL;
struct clk_fixed_factor *fix_factor;
struct clk_divider *divider;
+ struct factors_data factors = *data->factors;
+ char base_name[SUNXI_DIVS_BASE_NAME_MAX_LEN];
void __iomem *reg;
int ndivs = SUNXI_DIVS_MAX_QTY, i = 0;
int flags, clkflags;
@@ -991,8 +985,31 @@ static void __init sunxi_divs_clk_setup(struct device_node *node,
if (data->ndivs)
ndivs = data->ndivs;
+ /* Try to find a name for base factor clock */
+ for (i = 0; i < ndivs; i++) {
+ if (data->div[i].self) {
+ of_property_read_string_index(node, "clock-output-names",
+ i, &factors.name);
+ break;
+ }
+ }
+ /* If we don't have a .self clk use the first output-name up to '_' */
+ if (factors.name == NULL) {
+ of_property_read_string_index(node, "clock-output-names",
+ 0, &clk_name);
+
+ for (i = 0; i < SUNXI_DIVS_BASE_NAME_MAX_LEN - 1 &&
+ clk_name[i] != '_' &&
+ clk_name[i] != '\0'; i++) {
+ base_name[i] = clk_name[i];
+ }
+
+ base_name[i] = '\0';
+ factors.name = base_name;
+ }
+
/* Set up factor clock that we will be dividing */
- pclk = sunxi_factors_clk_setup(node, data->factors);
+ pclk = sunxi_factors_clk_setup(node, &factors);
parent = __clk_get_name(pclk);
reg = of_iomap(node, 0);
Currently, the sunxi clock driver gets the name for the base factor clock of divs clocks from the name field in factors_data. This prevents reusing of the factor clock for clocks with same properties, but different name. This commit makes the divs setup function try to get a name from clock-output-names in the devicetree. It also removes the name field where possible and merges the sun4i PLL5 and PLL6 clocks. Signed-off-by: Jens Kuske <jenskuske@gmail.com> --- drivers/clk/sunxi/clk-sunxi.c | 39 ++++++++++++++++++++++++++++----------- 1 file changed, 28 insertions(+), 11 deletions(-)