Commit Message

Matthias Kaehlcke July 2, 2018, 6:10 p.m. UTC
The thermal zone uses spmi-temp-alarm as sensor. If the sensor is
configured without an IIO input it always reports 37°C for temperatures
below the first hardware trip point at 105°C. This hardware trip point
is configured as critical trip point, to initiate a system shutdown
before the temperature reaches the next hardware trip point at 125°C,
where the PMIC performs a partial shutdown.

The temperature of the critical trip point can be raised after adding
the die temperature ADC as IIO input for spmi-temp-alarm, which
significantly increases the precision of the temperature measurements.

Signed-off-by: Matthias Kaehlcke <mka@chromium.org>
---
Changes in v2:
- defined 'thermal-zones' node in pm8998.dtsi instead of using a label
  to refer to it
- use 105°C hardware trip point as critical trip point
- reduced number of trip points to 2
- lowered temperature of passive trip point
- updated trip point names and added labels
- updated commit message

 arch/arm64/boot/dts/qcom/pm8998.dtsi | 25 +++++++++++++++++++++++++
 1 file changed, 25 insertions(+)

Comments

Doug Anderson July 2, 2018, 7:53 p.m. UTC | #1
Hi,

On Mon, Jul 2, 2018 at 11:10 AM, Matthias Kaehlcke <mka@chromium.org> wrote:
> The thermal zone uses spmi-temp-alarm as sensor. If the sensor is
> configured without an IIO input it always reports 37°C for temperatures
> below the first hardware trip point at 105°C. This hardware trip point
> is configured as critical trip point, to initiate a system shutdown
> before the temperature reaches the next hardware trip point at 125°C,
> where the PMIC performs a partial shutdown.
>
> The temperature of the critical trip point can be raised after adding
> the die temperature ADC as IIO input for spmi-temp-alarm, which
> significantly increases the precision of the temperature measurements.
>
> Signed-off-by: Matthias Kaehlcke <mka@chromium.org>
> ---
> Changes in v2:
> - defined 'thermal-zones' node in pm8998.dtsi instead of using a label
>   to refer to it
> - use 105°C hardware trip point as critical trip point

I'm not sure this was right.  I guess you're trying to avoid
Temperature Stage 2?  From Davi'd email in response to v1:

> The PMIC TEMP_ALARM hardware peripheral will perform an automatic partial
> PMIC shutdown upon hitting over-temperature stage 2 (125 C).  This turns
> off peripherals within the PMIC that are expected to draw significant
> current.  The set of peripherals included varies between PMICs.  This
> partial shutdown will occur simultaneously with the triggering of an
> interrupt to the APPS processor that informs the qcom-spmi-temp-alarm
> driver that an over-temperature threshold has been crossed.

I think it's actually OK to use Temperature Stage 2 as the "critical"
point, which is why it still interrupts the CPU.  At "critical" the
system will shut down, right?  ...so presumably it's OK if the drivers
can't recover from having the power yanked out from underneath them as
long as they don't hang/crash the system in this case.  If I had to
guess the whole point of this stage is to give the system shutdown a
better chance of succeeding without getting to stage 3.


I do agree, however, that removing the "145" from the device tree was
the right thing to do since software will never see that.  The system
will just shut down.


> - reduced number of trip points to 2
> - lowered temperature of passive trip point

This won't actually do anything until the ADC gets hooked up, right?

I guess I would have expected:
- 105: passive
- 125: critical

...and then we could add (if we wanted) a "hot" between passive and
critical once we have the ADC hooked up?



> - updated trip point names and added labels
> - updated commit message
>
>  arch/arm64/boot/dts/qcom/pm8998.dtsi | 25 +++++++++++++++++++++++++
>  1 file changed, 25 insertions(+)
>
> diff --git a/arch/arm64/boot/dts/qcom/pm8998.dtsi b/arch/arm64/boot/dts/qcom/pm8998.dtsi
> index 2f4989e7ef68..e7caa334e6c7 100644
> --- a/arch/arm64/boot/dts/qcom/pm8998.dtsi
> +++ b/arch/arm64/boot/dts/qcom/pm8998.dtsi
> @@ -3,6 +3,7 @@
>
>  #include <dt-bindings/spmi/spmi.h>
>  #include <dt-bindings/interrupt-controller/irq.h>
> +#include <dt-bindings/thermal/thermal.h>
>
>  &spmi_bus {
>         pm8998_lsid0: pmic@0 {
> @@ -60,3 +61,27 @@
>                 #size-cells = <0>;
>         };
>  };
> +
> +/ {
> +       thermal-zones {
> +               pm8998 {
> +                       polling-delay-passive = <250>;
> +                       polling-delay = <1000>;
> +
> +                       thermal-sensors = <&pm8998_temp>;
> +
> +                       trips {
> +                               pm8998_alert0: pm8998-alert0 {
> +                                       temperature = <95000>;
> +                                       hysteresis = <2000>;
> +                                       type = "passive";
> +                               };
> +                               pm8998_crit: pm8998-crit {
> +                                       temperature = <105000>;
> +                                       hysteresis = <2000>;
> +                                       type = "critical";
> +                               };
> +                       };
> +               };
> +       };
> +};

A nit, but I think convention is to actually put additions straight to
the root node before reference to phandles, so I would have put this
above the "&spmi_bus" part.
Matthias Kaehlcke July 2, 2018, 8:46 p.m. UTC | #2
On Mon, Jul 02, 2018 at 12:53:44PM -0700, Doug Anderson wrote:
> Hi,
> 
> On Mon, Jul 2, 2018 at 11:10 AM, Matthias Kaehlcke <mka@chromium.org> wrote:
> > The thermal zone uses spmi-temp-alarm as sensor. If the sensor is
> > configured without an IIO input it always reports 37°C for temperatures
> > below the first hardware trip point at 105°C. This hardware trip point
> > is configured as critical trip point, to initiate a system shutdown
> > before the temperature reaches the next hardware trip point at 125°C,
> > where the PMIC performs a partial shutdown.
> >
> > The temperature of the critical trip point can be raised after adding
> > the die temperature ADC as IIO input for spmi-temp-alarm, which
> > significantly increases the precision of the temperature measurements.
> >
> > Signed-off-by: Matthias Kaehlcke <mka@chromium.org>
> > ---
> > Changes in v2:
> > - defined 'thermal-zones' node in pm8998.dtsi instead of using a label
> >   to refer to it
> > - use 105°C hardware trip point as critical trip point
> 
> I'm not sure this was right.  I guess you're trying to avoid
> Temperature Stage 2?

Indeed

> From Davi'd email in response to v1:
> 
> > The PMIC TEMP_ALARM hardware peripheral will perform an automatic partial
> > PMIC shutdown upon hitting over-temperature stage 2 (125 C).  This turns
> > off peripherals within the PMIC that are expected to draw significant
> > current.  The set of peripherals included varies between PMICs.  This
> > partial shutdown will occur simultaneously with the triggering of an
> > interrupt to the APPS processor that informs the qcom-spmi-temp-alarm
> > driver that an over-temperature threshold has been crossed.
> 
> I think it's actually OK to use Temperature Stage 2 as the "critical"
> point, which is why it still interrupts the CPU.  At "critical" the
> system will shut down, right?  ...so presumably it's OK if the drivers
> can't recover from having the power yanked out from underneath them as
> long as they don't hang/crash the system in this case.  If I had to
> guess the whole point of this stage is to give the system shutdown a
> better chance of succeeding without getting to stage 3.

That was my starting point, however in my tests the system reset
several times when the temperature got close to 125°C, not allowing
for a proper shutdown. Apparently the partial shutdown of the PMIC can
result in a full reset at least on some systems.

> I do agree, however, that removing the "145" from the device tree was
> the right thing to do since software will never see that.  The system
> will just shut down.
> 
> 
> > - reduced number of trip points to 2
> > - lowered temperature of passive trip point
> 
> This won't actually do anything until the ADC gets hooked up, right?

Correct

> I guess I would have expected:
> - 105: passive
> - 125: critical
> 
> ...and then we could add (if we wanted) a "hot" between passive and
> critical once we have the ADC hooked up?

Exactly, once we have more granularity we could add (an)other trip point(s).

> > - updated trip point names and added labels
> > - updated commit message
> >
> >  arch/arm64/boot/dts/qcom/pm8998.dtsi | 25 +++++++++++++++++++++++++
> >  1 file changed, 25 insertions(+)
> >
> > diff --git a/arch/arm64/boot/dts/qcom/pm8998.dtsi b/arch/arm64/boot/dts/qcom/pm8998.dtsi
> > index 2f4989e7ef68..e7caa334e6c7 100644
> > --- a/arch/arm64/boot/dts/qcom/pm8998.dtsi
> > +++ b/arch/arm64/boot/dts/qcom/pm8998.dtsi
> > @@ -3,6 +3,7 @@
> >
> >  #include <dt-bindings/spmi/spmi.h>
> >  #include <dt-bindings/interrupt-controller/irq.h>
> > +#include <dt-bindings/thermal/thermal.h>
> >
> >  &spmi_bus {
> >         pm8998_lsid0: pmic@0 {
> > @@ -60,3 +61,27 @@
> >                 #size-cells = <0>;
> >         };
> >  };
> > +
> > +/ {
> > +       thermal-zones {
> > +               pm8998 {
> > +                       polling-delay-passive = <250>;
> > +                       polling-delay = <1000>;
> > +
> > +                       thermal-sensors = <&pm8998_temp>;
> > +
> > +                       trips {
> > +                               pm8998_alert0: pm8998-alert0 {
> > +                                       temperature = <95000>;
> > +                                       hysteresis = <2000>;
> > +                                       type = "passive";
> > +                               };
> > +                               pm8998_crit: pm8998-crit {
> > +                                       temperature = <105000>;
> > +                                       hysteresis = <2000>;
> > +                                       type = "critical";
> > +                               };
> > +                       };
> > +               };
> > +       };
> > +};
> 
> A nit, but I think convention is to actually put additions straight to
> the root node before reference to phandles, so I would have put this
> above the "&spmi_bus" part.

Ok, thanks, will do in v3
Matthias Kaehlcke July 2, 2018, 10:35 p.m. UTC | #3
On Mon, Jul 02, 2018 at 01:46:11PM -0700, Matthias Kaehlcke wrote:
> On Mon, Jul 02, 2018 at 12:53:44PM -0700, Doug Anderson wrote:
> > Hi,
> > 
> > On Mon, Jul 2, 2018 at 11:10 AM, Matthias Kaehlcke <mka@chromium.org> wrote:
> > > The thermal zone uses spmi-temp-alarm as sensor. If the sensor is
> > > configured without an IIO input it always reports 37°C for temperatures
> > > below the first hardware trip point at 105°C. This hardware trip point
> > > is configured as critical trip point, to initiate a system shutdown
> > > before the temperature reaches the next hardware trip point at 125°C,
> > > where the PMIC performs a partial shutdown.
> > >
> > > The temperature of the critical trip point can be raised after adding
> > > the die temperature ADC as IIO input for spmi-temp-alarm, which
> > > significantly increases the precision of the temperature measurements.
> > >
> > > Signed-off-by: Matthias Kaehlcke <mka@chromium.org>
> > > ---
> > > Changes in v2:
> > > - defined 'thermal-zones' node in pm8998.dtsi instead of using a label
> > >   to refer to it
> > > - use 105°C hardware trip point as critical trip point
> > 
> > I'm not sure this was right.  I guess you're trying to avoid
> > Temperature Stage 2?
> 
> Indeed
> 
> > From Davi'd email in response to v1:
> > 
> > > The PMIC TEMP_ALARM hardware peripheral will perform an automatic partial
> > > PMIC shutdown upon hitting over-temperature stage 2 (125 C).  This turns
> > > off peripherals within the PMIC that are expected to draw significant
> > > current.  The set of peripherals included varies between PMICs.  This
> > > partial shutdown will occur simultaneously with the triggering of an
> > > interrupt to the APPS processor that informs the qcom-spmi-temp-alarm
> > > driver that an over-temperature threshold has been crossed.
> > 
> > I think it's actually OK to use Temperature Stage 2 as the "critical"
> > point, which is why it still interrupts the CPU.  At "critical" the
> > system will shut down, right?  ...so presumably it's OK if the drivers
> > can't recover from having the power yanked out from underneath them as
> > long as they don't hang/crash the system in this case.  If I had to
> > guess the whole point of this stage is to give the system shutdown a
> > better chance of succeeding without getting to stage 3.
> 
> That was my starting point, however in my tests the system reset
> several times when the temperature got close to 125°C, not allowing
> for a proper shutdown. Apparently the partial shutdown of the PMIC can
> result in a full reset at least on some systems.

For the record: Linux does a proper shutdown when software override
for stage 2 is enabled (bit OVRD_ST2_EN in TEMP_ALARM_SHUTDOWN_CTL1).
diff mbox

Patch

diff --git a/arch/arm64/boot/dts/qcom/pm8998.dtsi b/arch/arm64/boot/dts/qcom/pm8998.dtsi
index 2f4989e7ef68..e7caa334e6c7 100644
--- a/arch/arm64/boot/dts/qcom/pm8998.dtsi
+++ b/arch/arm64/boot/dts/qcom/pm8998.dtsi
@@ -3,6 +3,7 @@ 
 
 #include <dt-bindings/spmi/spmi.h>
 #include <dt-bindings/interrupt-controller/irq.h>
+#include <dt-bindings/thermal/thermal.h>
 
 &spmi_bus {
 	pm8998_lsid0: pmic@0 {
@@ -60,3 +61,27 @@ 
 		#size-cells = <0>;
 	};
 };
+
+/ {
+	thermal-zones {
+		pm8998 {
+			polling-delay-passive = <250>;
+			polling-delay = <1000>;
+
+			thermal-sensors = <&pm8998_temp>;
+
+			trips {
+				pm8998_alert0: pm8998-alert0 {
+					temperature = <95000>;
+					hysteresis = <2000>;
+					type = "passive";
+				};
+				pm8998_crit: pm8998-crit {
+					temperature = <105000>;
+					hysteresis = <2000>;
+					type = "critical";
+				};
+			};
+		};
+	};
+};