Message ID | 20190530092038.12020-4-quentin.perret@arm.com (mailing list archive) |
---|---|
State | New, archived |
Headers | show |
Series | Make IPA use PM_EM | expand |
On Thursday 30 May 2019 at 10:20:38 (+0100), Quentin Perret wrote: > The newly introduced Energy Model framework manages power cost tables in > a generic way. Moreover, it supports several types of models since the > tables can come from DT or firmware (through SCMI) for example. On the > other hand, the cpu_cooling subsystem manages its own power cost tables > using only DT data. > > In order to avoid the duplication of data in the kernel, and in order to > enable IPA with EMs coming from more than just DT, remove the private > tables from cpu_cooling.c and migrate it to using the centralized EM > framework. Doing so should have no visible functional impact for > existing users of IPA since: > > - recent extenstions to the the PM_OPP infrastructure enable the > registration of EMs in PM_EM using the DT property used by IPA; > > - the existing upstream cpufreq drivers marked with the > 'CPUFREQ_IS_COOLING_DEV' flag all use the aforementioned PM_OPP > infrastructure, which means they all support PM_EM. The only two > exceptions are qoriq-cpufreq which doesn't in fact use an EM and > scmi-cpufreq which doesn't use DT for power costs. > > For existing users of cpu_cooling, PM_EM tables will contain the exact > same power values that IPA used to compute on its own until now. The > only new dependency for them is to compile in CONFIG_ENERGY_MODEL. > > The case where the thermal subsystem is used without an Energy Model > (cpufreq_cooling_ops) is handled by looking directly at CPUFreq's > frequency table which is already a dependency for cpu_cooling.c anyway. > Since the thermal framework expects the cooling states in a particular > order, bail out whenever the CPUFreq table is unsorted, since that is > fairly uncommon in general, and there are currently no users of > cpu_cooling for this use-case. > > Acked-by: Viresh Kumar <viresh.kumar@linaro.org> Viresh: the patch hasn't changed much so I kept this, but please shout if you're not happy with the new version :-) Thanks, Quentin
On 30-05-19, 12:27, Quentin Perret wrote: > On Thursday 30 May 2019 at 10:20:38 (+0100), Quentin Perret wrote: > > The newly introduced Energy Model framework manages power cost tables in > > a generic way. Moreover, it supports several types of models since the > > tables can come from DT or firmware (through SCMI) for example. On the > > other hand, the cpu_cooling subsystem manages its own power cost tables > > using only DT data. > > > > In order to avoid the duplication of data in the kernel, and in order to > > enable IPA with EMs coming from more than just DT, remove the private > > tables from cpu_cooling.c and migrate it to using the centralized EM > > framework. Doing so should have no visible functional impact for > > existing users of IPA since: > > > > - recent extenstions to the the PM_OPP infrastructure enable the > > registration of EMs in PM_EM using the DT property used by IPA; > > > > - the existing upstream cpufreq drivers marked with the > > 'CPUFREQ_IS_COOLING_DEV' flag all use the aforementioned PM_OPP > > infrastructure, which means they all support PM_EM. The only two > > exceptions are qoriq-cpufreq which doesn't in fact use an EM and > > scmi-cpufreq which doesn't use DT for power costs. > > > > For existing users of cpu_cooling, PM_EM tables will contain the exact > > same power values that IPA used to compute on its own until now. The > > only new dependency for them is to compile in CONFIG_ENERGY_MODEL. > > > > The case where the thermal subsystem is used without an Energy Model > > (cpufreq_cooling_ops) is handled by looking directly at CPUFreq's > > frequency table which is already a dependency for cpu_cooling.c anyway. > > Since the thermal framework expects the cooling states in a particular > > order, bail out whenever the CPUFreq table is unsorted, since that is > > fairly uncommon in general, and there are currently no users of > > cpu_cooling for this use-case. > > > > Acked-by: Viresh Kumar <viresh.kumar@linaro.org> > > Viresh: the patch hasn't changed much so I kept this, but please shout > if you're not happy with the new version :-) Yeah, it looked fine and so I didn't complain :)
On 30/05/2019 11:20, Quentin Perret wrote: > The newly introduced Energy Model framework manages power cost tables in > a generic way. Moreover, it supports several types of models since the > tables can come from DT or firmware (through SCMI) for example. On the > other hand, the cpu_cooling subsystem manages its own power cost tables > using only DT data. > > In order to avoid the duplication of data in the kernel, and in order to > enable IPA with EMs coming from more than just DT, remove the private > tables from cpu_cooling.c and migrate it to using the centralized EM > framework. Doing so should have no visible functional impact for > existing users of IPA since: > > - recent extenstions to the the PM_OPP infrastructure enable the > registration of EMs in PM_EM using the DT property used by IPA; > > - the existing upstream cpufreq drivers marked with the > 'CPUFREQ_IS_COOLING_DEV' flag all use the aforementioned PM_OPP > infrastructure, which means they all support PM_EM. The only two > exceptions are qoriq-cpufreq which doesn't in fact use an EM and > scmi-cpufreq which doesn't use DT for power costs. > > For existing users of cpu_cooling, PM_EM tables will contain the exact > same power values that IPA used to compute on its own until now. The > only new dependency for them is to compile in CONFIG_ENERGY_MODEL. > > The case where the thermal subsystem is used without an Energy Model > (cpufreq_cooling_ops) is handled by looking directly at CPUFreq's > frequency table which is already a dependency for cpu_cooling.c anyway. > Since the thermal framework expects the cooling states in a particular > order, bail out whenever the CPUFreq table is unsorted, since that is > fairly uncommon in general, and there are currently no users of > cpu_cooling for this use-case. > > Acked-by: Viresh Kumar <viresh.kumar@linaro.org> > Signed-off-by: Quentin Perret <quentin.perret@arm.com> Acked-by: Daniel Lezcano <daniel.lezcano@linaro.org> > --- > drivers/thermal/Kconfig | 1 + > drivers/thermal/cpu_cooling.c | 250 ++++++++++++---------------------- > 2 files changed, 91 insertions(+), 160 deletions(-) > > diff --git a/drivers/thermal/Kconfig b/drivers/thermal/Kconfig > index 9966364a6deb..340853a3ca48 100644 > --- a/drivers/thermal/Kconfig > +++ b/drivers/thermal/Kconfig > @@ -144,6 +144,7 @@ config THERMAL_GOV_USER_SPACE > > config THERMAL_GOV_POWER_ALLOCATOR > bool "Power allocator thermal governor" > + depends on ENERGY_MODEL > help > Enable this to manage platform thermals by dynamically > allocating and limiting power to devices. > diff --git a/drivers/thermal/cpu_cooling.c b/drivers/thermal/cpu_cooling.c > index 498f59ab64b2..83486775e593 100644 > --- a/drivers/thermal/cpu_cooling.c > +++ b/drivers/thermal/cpu_cooling.c > @@ -19,6 +19,7 @@ > #include <linux/slab.h> > #include <linux/cpu.h> > #include <linux/cpu_cooling.h> > +#include <linux/energy_model.h> > > #include <trace/events/thermal.h> > > @@ -36,21 +37,6 @@ > * ... > */ > > -/** > - * struct freq_table - frequency table along with power entries > - * @frequency: frequency in KHz > - * @power: power in mW > - * > - * This structure is built when the cooling device registers and helps > - * in translating frequency to power and vice versa. > - */ > -struct freq_table { > - u32 frequency; > -#ifdef CONFIG_THERMAL_GOV_POWER_ALLOCATOR > - u32 power; > -#endif > -}; > - > /** > * struct time_in_idle - Idle time stats > * @time: previous reading of the absolute time that this cpu was idle > @@ -72,7 +58,7 @@ struct time_in_idle { > * frequency. > * @max_level: maximum cooling level. One less than total number of valid > * cpufreq frequencies. > - * @freq_table: Freq table in descending order of frequencies > + * @em: Reference on the Energy Model of the device > * @cdev: thermal_cooling_device pointer to keep track of the > * registered cooling device. > * @policy: cpufreq policy. > @@ -88,7 +74,7 @@ struct cpufreq_cooling_device { > unsigned int cpufreq_state; > unsigned int clipped_freq; > unsigned int max_level; > - struct freq_table *freq_table; /* In descending order */ > + struct em_perf_domain *em; > struct cpufreq_policy *policy; > struct list_head node; > struct time_in_idle *idle_time; > @@ -162,114 +148,40 @@ static int cpufreq_thermal_notifier(struct notifier_block *nb, > static unsigned long get_level(struct cpufreq_cooling_device *cpufreq_cdev, > unsigned int freq) > { > - struct freq_table *freq_table = cpufreq_cdev->freq_table; > - unsigned long level; > + int i; > > - for (level = 1; level <= cpufreq_cdev->max_level; level++) > - if (freq > freq_table[level].frequency) > + for (i = cpufreq_cdev->max_level - 1; i >= 0; i--) { > + if (freq > cpufreq_cdev->em->table[i].frequency) > break; > - > - return level - 1; > -} > - > -/** > - * update_freq_table() - Update the freq table with power numbers > - * @cpufreq_cdev: the cpufreq cooling device in which to update the table > - * @capacitance: dynamic power coefficient for these cpus > - * > - * Update the freq table with power numbers. This table will be used in > - * cpu_power_to_freq() and cpu_freq_to_power() to convert between power and > - * frequency efficiently. Power is stored in mW, frequency in KHz. The > - * resulting table is in descending order. > - * > - * Return: 0 on success, -EINVAL if there are no OPPs for any CPUs, > - * or -ENOMEM if we run out of memory. > - */ > -static int update_freq_table(struct cpufreq_cooling_device *cpufreq_cdev, > - u32 capacitance) > -{ > - struct freq_table *freq_table = cpufreq_cdev->freq_table; > - struct dev_pm_opp *opp; > - struct device *dev = NULL; > - int num_opps = 0, cpu = cpufreq_cdev->policy->cpu, i; > - > - dev = get_cpu_device(cpu); > - if (unlikely(!dev)) { > - pr_warn("No cpu device for cpu %d\n", cpu); > - return -ENODEV; > - } > - > - num_opps = dev_pm_opp_get_opp_count(dev); > - if (num_opps < 0) > - return num_opps; > - > - /* > - * The cpufreq table is also built from the OPP table and so the count > - * should match. > - */ > - if (num_opps != cpufreq_cdev->max_level + 1) { > - dev_warn(dev, "Number of OPPs not matching with max_levels\n"); > - return -EINVAL; > - } > - > - for (i = 0; i <= cpufreq_cdev->max_level; i++) { > - unsigned long freq = freq_table[i].frequency * 1000; > - u32 freq_mhz = freq_table[i].frequency / 1000; > - u64 power; > - u32 voltage_mv; > - > - /* > - * Find ceil frequency as 'freq' may be slightly lower than OPP > - * freq due to truncation while converting to kHz. > - */ > - opp = dev_pm_opp_find_freq_ceil(dev, &freq); > - if (IS_ERR(opp)) { > - dev_err(dev, "failed to get opp for %lu frequency\n", > - freq); > - return -EINVAL; > - } > - > - voltage_mv = dev_pm_opp_get_voltage(opp) / 1000; > - dev_pm_opp_put(opp); > - > - /* > - * Do the multiplication with MHz and millivolt so as > - * to not overflow. > - */ > - power = (u64)capacitance * freq_mhz * voltage_mv * voltage_mv; > - do_div(power, 1000000000); > - > - /* power is stored in mW */ > - freq_table[i].power = power; > } > > - return 0; > + return cpufreq_cdev->max_level - i - 1; > } > > static u32 cpu_freq_to_power(struct cpufreq_cooling_device *cpufreq_cdev, > u32 freq) > { > int i; > - struct freq_table *freq_table = cpufreq_cdev->freq_table; > > - for (i = 1; i <= cpufreq_cdev->max_level; i++) > - if (freq > freq_table[i].frequency) > + for (i = cpufreq_cdev->max_level - 1; i >= 0; i--) { > + if (freq > cpufreq_cdev->em->table[i].frequency) > break; > + } > > - return freq_table[i - 1].power; > + return cpufreq_cdev->em->table[i + 1].power; > } > > static u32 cpu_power_to_freq(struct cpufreq_cooling_device *cpufreq_cdev, > u32 power) > { > int i; > - struct freq_table *freq_table = cpufreq_cdev->freq_table; > > - for (i = 1; i <= cpufreq_cdev->max_level; i++) > - if (power > freq_table[i].power) > + for (i = cpufreq_cdev->max_level - 1; i >= 0; i--) { > + if (power > cpufreq_cdev->em->table[i].power) > break; > + } > > - return freq_table[i - 1].frequency; > + return cpufreq_cdev->em->table[i + 1].frequency; > } > > /** > @@ -410,7 +322,7 @@ static int cpufreq_state2power(struct thermal_cooling_device *cdev, > struct thermal_zone_device *tz, > unsigned long state, u32 *power) > { > - unsigned int freq, num_cpus; > + unsigned int freq, num_cpus, idx; > struct cpufreq_cooling_device *cpufreq_cdev = cdev->devdata; > > /* Request state should be less than max_level */ > @@ -419,7 +331,8 @@ static int cpufreq_state2power(struct thermal_cooling_device *cdev, > > num_cpus = cpumask_weight(cpufreq_cdev->policy->cpus); > > - freq = cpufreq_cdev->freq_table[state].frequency; > + idx = cpufreq_cdev->max_level - state; > + freq = cpufreq_cdev->em->table[idx].frequency; > *power = cpu_freq_to_power(cpufreq_cdev, freq) * num_cpus; > > return 0; > @@ -463,8 +376,60 @@ static int cpufreq_power2state(struct thermal_cooling_device *cdev, > power); > return 0; > } > + > +static inline bool em_is_sane(struct cpufreq_cooling_device *cpufreq_cdev, > + struct em_perf_domain *em) { > + struct cpufreq_policy *policy; > + unsigned int nr_levels; > + > + if (!em) > + return false; > + > + policy = cpufreq_cdev->policy; > + if (!cpumask_equal(policy->related_cpus, to_cpumask(em->cpus))) { > + pr_err("The span of pd %*pbl is misaligned with cpufreq policy %*pbl\n", > + cpumask_pr_args(to_cpumask(em->cpus)), > + cpumask_pr_args(policy->related_cpus)); > + return false; > + } > + > + nr_levels = cpufreq_cdev->max_level + 1; > + if (em->nr_cap_states != nr_levels) { > + pr_err("The number of cap states in pd %*pbl (%u) doesn't match the number of cooling levels (%u)\n", > + cpumask_pr_args(to_cpumask(em->cpus)), > + em->nr_cap_states, nr_levels); > + return false; > + } > + > + return true; > +} > #endif /* CONFIG_THERMAL_GOV_POWER_ALLOCATOR */ > > +static unsigned int get_state_freq(struct cpufreq_cooling_device *cpufreq_cdev, > + unsigned long state) > +{ > + struct cpufreq_policy *policy; > + unsigned long idx; > + > +#ifdef CONFIG_THERMAL_GOV_POWER_ALLOCATOR > + /* Use the Energy Model table if available */ > + if (cpufreq_cdev->em) { > + idx = cpufreq_cdev->max_level - state; > + return cpufreq_cdev->em->table[idx].frequency; > + } > +#endif > + > + /* Otherwise, fallback on the CPUFreq table */ > + policy = cpufreq_cdev->policy; > + if (policy->freq_table_sorted == CPUFREQ_TABLE_SORTED_ASCENDING) > + idx = cpufreq_cdev->max_level - state; > + else > + idx = state; > + > + return policy->freq_table[idx].frequency; > +} > + > + > /* cpufreq cooling device callback functions are defined below */ > > /** > @@ -530,7 +495,7 @@ static int cpufreq_set_cur_state(struct thermal_cooling_device *cdev, > if (cpufreq_cdev->cpufreq_state == state) > return 0; > > - clip_freq = cpufreq_cdev->freq_table[state].frequency; > + clip_freq = get_state_freq(cpufreq_cdev, state); > cpufreq_cdev->cpufreq_state = state; > cpufreq_cdev->clipped_freq = clip_freq; > > @@ -552,26 +517,12 @@ static struct notifier_block thermal_cpufreq_notifier_block = { > .notifier_call = cpufreq_thermal_notifier, > }; > > -static unsigned int find_next_max(struct cpufreq_frequency_table *table, > - unsigned int prev_max) > -{ > - struct cpufreq_frequency_table *pos; > - unsigned int max = 0; > - > - cpufreq_for_each_valid_entry(pos, table) { > - if (pos->frequency > max && pos->frequency < prev_max) > - max = pos->frequency; > - } > - > - return max; > -} > - > /** > * __cpufreq_cooling_register - helper function to create cpufreq cooling device > * @np: a valid struct device_node to the cooling device device tree node > * @policy: cpufreq policy > * Normally this should be same as cpufreq policy->related_cpus. > - * @capacitance: dynamic power coefficient for these cpus > + * @em: Energy Model of the cpufreq policy > * > * This interface function registers the cpufreq cooling device with the name > * "thermal-cpufreq-%x". This api can support multiple instances of cpufreq > @@ -583,12 +534,13 @@ static unsigned int find_next_max(struct cpufreq_frequency_table *table, > */ > static struct thermal_cooling_device * > __cpufreq_cooling_register(struct device_node *np, > - struct cpufreq_policy *policy, u32 capacitance) > + struct cpufreq_policy *policy, > + struct em_perf_domain *em) > { > struct thermal_cooling_device *cdev; > struct cpufreq_cooling_device *cpufreq_cdev; > char dev_name[THERMAL_NAME_LENGTH]; > - unsigned int freq, i, num_cpus; > + unsigned int i, num_cpus; > int ret; > struct thermal_cooling_device_ops *cooling_ops; > bool first; > @@ -622,55 +574,38 @@ __cpufreq_cooling_register(struct device_node *np, > /* max_level is an index, not a counter */ > cpufreq_cdev->max_level = i - 1; > > - cpufreq_cdev->freq_table = kmalloc_array(i, > - sizeof(*cpufreq_cdev->freq_table), > - GFP_KERNEL); > - if (!cpufreq_cdev->freq_table) { > - cdev = ERR_PTR(-ENOMEM); > - goto free_idle_time; > - } > - > ret = ida_simple_get(&cpufreq_ida, 0, 0, GFP_KERNEL); > if (ret < 0) { > cdev = ERR_PTR(ret); > - goto free_table; > + goto free_idle_time; > } > cpufreq_cdev->id = ret; > > snprintf(dev_name, sizeof(dev_name), "thermal-cpufreq-%d", > cpufreq_cdev->id); > > - /* Fill freq-table in descending order of frequencies */ > - for (i = 0, freq = -1; i <= cpufreq_cdev->max_level; i++) { > - freq = find_next_max(policy->freq_table, freq); > - cpufreq_cdev->freq_table[i].frequency = freq; > - > - /* Warn for duplicate entries */ > - if (!freq) > - pr_warn("%s: table has duplicate entries\n", __func__); > - else > - pr_debug("%s: freq:%u KHz\n", __func__, freq); > - } > - > cooling_ops = &cpufreq_cooling_ops; > #ifdef CONFIG_THERMAL_GOV_POWER_ALLOCATOR > - if (capacitance) { > - ret = update_freq_table(cpufreq_cdev, capacitance); > - if (ret) { > - cdev = ERR_PTR(ret); > - goto remove_ida; > - } > + if (em_is_sane(cpufreq_cdev, em)) { > + cpufreq_cdev->em = em; > cooling_ops->get_requested_power = cpufreq_get_requested_power; > cooling_ops->state2power = cpufreq_state2power; > cooling_ops->power2state = cpufreq_power2state; > - } > + } else > #endif > + if (policy->freq_table_sorted == CPUFREQ_TABLE_UNSORTED) { > + pr_err("%s: unsorted frequency tables are not supported\n", > + __func__); > + cdev = ERR_PTR(-EINVAL); > + goto remove_ida; > + } > + > cdev = thermal_of_cooling_device_register(np, dev_name, cpufreq_cdev, > cooling_ops); > if (IS_ERR(cdev)) > goto remove_ida; > > - cpufreq_cdev->clipped_freq = cpufreq_cdev->freq_table[0].frequency; > + cpufreq_cdev->clipped_freq = get_state_freq(cpufreq_cdev, 0); > > mutex_lock(&cooling_list_lock); > /* Register the notifier for first cpufreq cooling device */ > @@ -686,8 +621,6 @@ __cpufreq_cooling_register(struct device_node *np, > > remove_ida: > ida_simple_remove(&cpufreq_ida, cpufreq_cdev->id); > -free_table: > - kfree(cpufreq_cdev->freq_table); > free_idle_time: > kfree(cpufreq_cdev->idle_time); > free_cdev: > @@ -709,7 +642,7 @@ __cpufreq_cooling_register(struct device_node *np, > struct thermal_cooling_device * > cpufreq_cooling_register(struct cpufreq_policy *policy) > { > - return __cpufreq_cooling_register(NULL, policy, 0); > + return __cpufreq_cooling_register(NULL, policy, NULL); > } > EXPORT_SYMBOL_GPL(cpufreq_cooling_register); > > @@ -737,7 +670,6 @@ of_cpufreq_cooling_register(struct cpufreq_policy *policy) > { > struct device_node *np = of_get_cpu_node(policy->cpu, NULL); > struct thermal_cooling_device *cdev = NULL; > - u32 capacitance = 0; > > if (!np) { > pr_err("cpu_cooling: OF node not available for cpu%d\n", > @@ -746,10 +678,9 @@ of_cpufreq_cooling_register(struct cpufreq_policy *policy) > } > > if (of_find_property(np, "#cooling-cells", NULL)) { > - of_property_read_u32(np, "dynamic-power-coefficient", > - &capacitance); > + struct em_perf_domain *em = em_cpu_get(policy->cpu); > > - cdev = __cpufreq_cooling_register(np, policy, capacitance); > + cdev = __cpufreq_cooling_register(np, policy, em); > if (IS_ERR(cdev)) { > pr_err("cpu_cooling: cpu%d failed to register as cooling device: %ld\n", > policy->cpu, PTR_ERR(cdev)); > @@ -791,7 +722,6 @@ void cpufreq_cooling_unregister(struct thermal_cooling_device *cdev) > thermal_cooling_device_unregister(cdev); > ida_simple_remove(&cpufreq_ida, cpufreq_cdev->id); > kfree(cpufreq_cdev->idle_time); > - kfree(cpufreq_cdev->freq_table); > kfree(cpufreq_cdev); > } > EXPORT_SYMBOL_GPL(cpufreq_cooling_unregister); >
On Saturday 01 Jun 2019 at 12:37:06 (+0200), Daniel Lezcano wrote: > On 30/05/2019 11:20, Quentin Perret wrote: > > The newly introduced Energy Model framework manages power cost tables in > > a generic way. Moreover, it supports several types of models since the > > tables can come from DT or firmware (through SCMI) for example. On the > > other hand, the cpu_cooling subsystem manages its own power cost tables > > using only DT data. > > > > In order to avoid the duplication of data in the kernel, and in order to > > enable IPA with EMs coming from more than just DT, remove the private > > tables from cpu_cooling.c and migrate it to using the centralized EM > > framework. Doing so should have no visible functional impact for > > existing users of IPA since: > > > > - recent extenstions to the the PM_OPP infrastructure enable the > > registration of EMs in PM_EM using the DT property used by IPA; > > > > - the existing upstream cpufreq drivers marked with the > > 'CPUFREQ_IS_COOLING_DEV' flag all use the aforementioned PM_OPP > > infrastructure, which means they all support PM_EM. The only two > > exceptions are qoriq-cpufreq which doesn't in fact use an EM and > > scmi-cpufreq which doesn't use DT for power costs. > > > > For existing users of cpu_cooling, PM_EM tables will contain the exact > > same power values that IPA used to compute on its own until now. The > > only new dependency for them is to compile in CONFIG_ENERGY_MODEL. > > > > The case where the thermal subsystem is used without an Energy Model > > (cpufreq_cooling_ops) is handled by looking directly at CPUFreq's > > frequency table which is already a dependency for cpu_cooling.c anyway. > > Since the thermal framework expects the cooling states in a particular > > order, bail out whenever the CPUFreq table is unsorted, since that is > > fairly uncommon in general, and there are currently no users of > > cpu_cooling for this use-case. > > > > Acked-by: Viresh Kumar <viresh.kumar@linaro.org> > > Signed-off-by: Quentin Perret <quentin.perret@arm.com> > > Acked-by: Daniel Lezcano <daniel.lezcano@linaro.org> Thanks for this one and the other one :-) Quentin
diff --git a/drivers/thermal/Kconfig b/drivers/thermal/Kconfig index 9966364a6deb..340853a3ca48 100644 --- a/drivers/thermal/Kconfig +++ b/drivers/thermal/Kconfig @@ -144,6 +144,7 @@ config THERMAL_GOV_USER_SPACE config THERMAL_GOV_POWER_ALLOCATOR bool "Power allocator thermal governor" + depends on ENERGY_MODEL help Enable this to manage platform thermals by dynamically allocating and limiting power to devices. diff --git a/drivers/thermal/cpu_cooling.c b/drivers/thermal/cpu_cooling.c index 498f59ab64b2..83486775e593 100644 --- a/drivers/thermal/cpu_cooling.c +++ b/drivers/thermal/cpu_cooling.c @@ -19,6 +19,7 @@ #include <linux/slab.h> #include <linux/cpu.h> #include <linux/cpu_cooling.h> +#include <linux/energy_model.h> #include <trace/events/thermal.h> @@ -36,21 +37,6 @@ * ... */ -/** - * struct freq_table - frequency table along with power entries - * @frequency: frequency in KHz - * @power: power in mW - * - * This structure is built when the cooling device registers and helps - * in translating frequency to power and vice versa. - */ -struct freq_table { - u32 frequency; -#ifdef CONFIG_THERMAL_GOV_POWER_ALLOCATOR - u32 power; -#endif -}; - /** * struct time_in_idle - Idle time stats * @time: previous reading of the absolute time that this cpu was idle @@ -72,7 +58,7 @@ struct time_in_idle { * frequency. * @max_level: maximum cooling level. One less than total number of valid * cpufreq frequencies. - * @freq_table: Freq table in descending order of frequencies + * @em: Reference on the Energy Model of the device * @cdev: thermal_cooling_device pointer to keep track of the * registered cooling device. * @policy: cpufreq policy. @@ -88,7 +74,7 @@ struct cpufreq_cooling_device { unsigned int cpufreq_state; unsigned int clipped_freq; unsigned int max_level; - struct freq_table *freq_table; /* In descending order */ + struct em_perf_domain *em; struct cpufreq_policy *policy; struct list_head node; struct time_in_idle *idle_time; @@ -162,114 +148,40 @@ static int cpufreq_thermal_notifier(struct notifier_block *nb, static unsigned long get_level(struct cpufreq_cooling_device *cpufreq_cdev, unsigned int freq) { - struct freq_table *freq_table = cpufreq_cdev->freq_table; - unsigned long level; + int i; - for (level = 1; level <= cpufreq_cdev->max_level; level++) - if (freq > freq_table[level].frequency) + for (i = cpufreq_cdev->max_level - 1; i >= 0; i--) { + if (freq > cpufreq_cdev->em->table[i].frequency) break; - - return level - 1; -} - -/** - * update_freq_table() - Update the freq table with power numbers - * @cpufreq_cdev: the cpufreq cooling device in which to update the table - * @capacitance: dynamic power coefficient for these cpus - * - * Update the freq table with power numbers. This table will be used in - * cpu_power_to_freq() and cpu_freq_to_power() to convert between power and - * frequency efficiently. Power is stored in mW, frequency in KHz. The - * resulting table is in descending order. - * - * Return: 0 on success, -EINVAL if there are no OPPs for any CPUs, - * or -ENOMEM if we run out of memory. - */ -static int update_freq_table(struct cpufreq_cooling_device *cpufreq_cdev, - u32 capacitance) -{ - struct freq_table *freq_table = cpufreq_cdev->freq_table; - struct dev_pm_opp *opp; - struct device *dev = NULL; - int num_opps = 0, cpu = cpufreq_cdev->policy->cpu, i; - - dev = get_cpu_device(cpu); - if (unlikely(!dev)) { - pr_warn("No cpu device for cpu %d\n", cpu); - return -ENODEV; - } - - num_opps = dev_pm_opp_get_opp_count(dev); - if (num_opps < 0) - return num_opps; - - /* - * The cpufreq table is also built from the OPP table and so the count - * should match. - */ - if (num_opps != cpufreq_cdev->max_level + 1) { - dev_warn(dev, "Number of OPPs not matching with max_levels\n"); - return -EINVAL; - } - - for (i = 0; i <= cpufreq_cdev->max_level; i++) { - unsigned long freq = freq_table[i].frequency * 1000; - u32 freq_mhz = freq_table[i].frequency / 1000; - u64 power; - u32 voltage_mv; - - /* - * Find ceil frequency as 'freq' may be slightly lower than OPP - * freq due to truncation while converting to kHz. - */ - opp = dev_pm_opp_find_freq_ceil(dev, &freq); - if (IS_ERR(opp)) { - dev_err(dev, "failed to get opp for %lu frequency\n", - freq); - return -EINVAL; - } - - voltage_mv = dev_pm_opp_get_voltage(opp) / 1000; - dev_pm_opp_put(opp); - - /* - * Do the multiplication with MHz and millivolt so as - * to not overflow. - */ - power = (u64)capacitance * freq_mhz * voltage_mv * voltage_mv; - do_div(power, 1000000000); - - /* power is stored in mW */ - freq_table[i].power = power; } - return 0; + return cpufreq_cdev->max_level - i - 1; } static u32 cpu_freq_to_power(struct cpufreq_cooling_device *cpufreq_cdev, u32 freq) { int i; - struct freq_table *freq_table = cpufreq_cdev->freq_table; - for (i = 1; i <= cpufreq_cdev->max_level; i++) - if (freq > freq_table[i].frequency) + for (i = cpufreq_cdev->max_level - 1; i >= 0; i--) { + if (freq > cpufreq_cdev->em->table[i].frequency) break; + } - return freq_table[i - 1].power; + return cpufreq_cdev->em->table[i + 1].power; } static u32 cpu_power_to_freq(struct cpufreq_cooling_device *cpufreq_cdev, u32 power) { int i; - struct freq_table *freq_table = cpufreq_cdev->freq_table; - for (i = 1; i <= cpufreq_cdev->max_level; i++) - if (power > freq_table[i].power) + for (i = cpufreq_cdev->max_level - 1; i >= 0; i--) { + if (power > cpufreq_cdev->em->table[i].power) break; + } - return freq_table[i - 1].frequency; + return cpufreq_cdev->em->table[i + 1].frequency; } /** @@ -410,7 +322,7 @@ static int cpufreq_state2power(struct thermal_cooling_device *cdev, struct thermal_zone_device *tz, unsigned long state, u32 *power) { - unsigned int freq, num_cpus; + unsigned int freq, num_cpus, idx; struct cpufreq_cooling_device *cpufreq_cdev = cdev->devdata; /* Request state should be less than max_level */ @@ -419,7 +331,8 @@ static int cpufreq_state2power(struct thermal_cooling_device *cdev, num_cpus = cpumask_weight(cpufreq_cdev->policy->cpus); - freq = cpufreq_cdev->freq_table[state].frequency; + idx = cpufreq_cdev->max_level - state; + freq = cpufreq_cdev->em->table[idx].frequency; *power = cpu_freq_to_power(cpufreq_cdev, freq) * num_cpus; return 0; @@ -463,8 +376,60 @@ static int cpufreq_power2state(struct thermal_cooling_device *cdev, power); return 0; } + +static inline bool em_is_sane(struct cpufreq_cooling_device *cpufreq_cdev, + struct em_perf_domain *em) { + struct cpufreq_policy *policy; + unsigned int nr_levels; + + if (!em) + return false; + + policy = cpufreq_cdev->policy; + if (!cpumask_equal(policy->related_cpus, to_cpumask(em->cpus))) { + pr_err("The span of pd %*pbl is misaligned with cpufreq policy %*pbl\n", + cpumask_pr_args(to_cpumask(em->cpus)), + cpumask_pr_args(policy->related_cpus)); + return false; + } + + nr_levels = cpufreq_cdev->max_level + 1; + if (em->nr_cap_states != nr_levels) { + pr_err("The number of cap states in pd %*pbl (%u) doesn't match the number of cooling levels (%u)\n", + cpumask_pr_args(to_cpumask(em->cpus)), + em->nr_cap_states, nr_levels); + return false; + } + + return true; +} #endif /* CONFIG_THERMAL_GOV_POWER_ALLOCATOR */ +static unsigned int get_state_freq(struct cpufreq_cooling_device *cpufreq_cdev, + unsigned long state) +{ + struct cpufreq_policy *policy; + unsigned long idx; + +#ifdef CONFIG_THERMAL_GOV_POWER_ALLOCATOR + /* Use the Energy Model table if available */ + if (cpufreq_cdev->em) { + idx = cpufreq_cdev->max_level - state; + return cpufreq_cdev->em->table[idx].frequency; + } +#endif + + /* Otherwise, fallback on the CPUFreq table */ + policy = cpufreq_cdev->policy; + if (policy->freq_table_sorted == CPUFREQ_TABLE_SORTED_ASCENDING) + idx = cpufreq_cdev->max_level - state; + else + idx = state; + + return policy->freq_table[idx].frequency; +} + + /* cpufreq cooling device callback functions are defined below */ /** @@ -530,7 +495,7 @@ static int cpufreq_set_cur_state(struct thermal_cooling_device *cdev, if (cpufreq_cdev->cpufreq_state == state) return 0; - clip_freq = cpufreq_cdev->freq_table[state].frequency; + clip_freq = get_state_freq(cpufreq_cdev, state); cpufreq_cdev->cpufreq_state = state; cpufreq_cdev->clipped_freq = clip_freq; @@ -552,26 +517,12 @@ static struct notifier_block thermal_cpufreq_notifier_block = { .notifier_call = cpufreq_thermal_notifier, }; -static unsigned int find_next_max(struct cpufreq_frequency_table *table, - unsigned int prev_max) -{ - struct cpufreq_frequency_table *pos; - unsigned int max = 0; - - cpufreq_for_each_valid_entry(pos, table) { - if (pos->frequency > max && pos->frequency < prev_max) - max = pos->frequency; - } - - return max; -} - /** * __cpufreq_cooling_register - helper function to create cpufreq cooling device * @np: a valid struct device_node to the cooling device device tree node * @policy: cpufreq policy * Normally this should be same as cpufreq policy->related_cpus. - * @capacitance: dynamic power coefficient for these cpus + * @em: Energy Model of the cpufreq policy * * This interface function registers the cpufreq cooling device with the name * "thermal-cpufreq-%x". This api can support multiple instances of cpufreq @@ -583,12 +534,13 @@ static unsigned int find_next_max(struct cpufreq_frequency_table *table, */ static struct thermal_cooling_device * __cpufreq_cooling_register(struct device_node *np, - struct cpufreq_policy *policy, u32 capacitance) + struct cpufreq_policy *policy, + struct em_perf_domain *em) { struct thermal_cooling_device *cdev; struct cpufreq_cooling_device *cpufreq_cdev; char dev_name[THERMAL_NAME_LENGTH]; - unsigned int freq, i, num_cpus; + unsigned int i, num_cpus; int ret; struct thermal_cooling_device_ops *cooling_ops; bool first; @@ -622,55 +574,38 @@ __cpufreq_cooling_register(struct device_node *np, /* max_level is an index, not a counter */ cpufreq_cdev->max_level = i - 1; - cpufreq_cdev->freq_table = kmalloc_array(i, - sizeof(*cpufreq_cdev->freq_table), - GFP_KERNEL); - if (!cpufreq_cdev->freq_table) { - cdev = ERR_PTR(-ENOMEM); - goto free_idle_time; - } - ret = ida_simple_get(&cpufreq_ida, 0, 0, GFP_KERNEL); if (ret < 0) { cdev = ERR_PTR(ret); - goto free_table; + goto free_idle_time; } cpufreq_cdev->id = ret; snprintf(dev_name, sizeof(dev_name), "thermal-cpufreq-%d", cpufreq_cdev->id); - /* Fill freq-table in descending order of frequencies */ - for (i = 0, freq = -1; i <= cpufreq_cdev->max_level; i++) { - freq = find_next_max(policy->freq_table, freq); - cpufreq_cdev->freq_table[i].frequency = freq; - - /* Warn for duplicate entries */ - if (!freq) - pr_warn("%s: table has duplicate entries\n", __func__); - else - pr_debug("%s: freq:%u KHz\n", __func__, freq); - } - cooling_ops = &cpufreq_cooling_ops; #ifdef CONFIG_THERMAL_GOV_POWER_ALLOCATOR - if (capacitance) { - ret = update_freq_table(cpufreq_cdev, capacitance); - if (ret) { - cdev = ERR_PTR(ret); - goto remove_ida; - } + if (em_is_sane(cpufreq_cdev, em)) { + cpufreq_cdev->em = em; cooling_ops->get_requested_power = cpufreq_get_requested_power; cooling_ops->state2power = cpufreq_state2power; cooling_ops->power2state = cpufreq_power2state; - } + } else #endif + if (policy->freq_table_sorted == CPUFREQ_TABLE_UNSORTED) { + pr_err("%s: unsorted frequency tables are not supported\n", + __func__); + cdev = ERR_PTR(-EINVAL); + goto remove_ida; + } + cdev = thermal_of_cooling_device_register(np, dev_name, cpufreq_cdev, cooling_ops); if (IS_ERR(cdev)) goto remove_ida; - cpufreq_cdev->clipped_freq = cpufreq_cdev->freq_table[0].frequency; + cpufreq_cdev->clipped_freq = get_state_freq(cpufreq_cdev, 0); mutex_lock(&cooling_list_lock); /* Register the notifier for first cpufreq cooling device */ @@ -686,8 +621,6 @@ __cpufreq_cooling_register(struct device_node *np, remove_ida: ida_simple_remove(&cpufreq_ida, cpufreq_cdev->id); -free_table: - kfree(cpufreq_cdev->freq_table); free_idle_time: kfree(cpufreq_cdev->idle_time); free_cdev: @@ -709,7 +642,7 @@ __cpufreq_cooling_register(struct device_node *np, struct thermal_cooling_device * cpufreq_cooling_register(struct cpufreq_policy *policy) { - return __cpufreq_cooling_register(NULL, policy, 0); + return __cpufreq_cooling_register(NULL, policy, NULL); } EXPORT_SYMBOL_GPL(cpufreq_cooling_register); @@ -737,7 +670,6 @@ of_cpufreq_cooling_register(struct cpufreq_policy *policy) { struct device_node *np = of_get_cpu_node(policy->cpu, NULL); struct thermal_cooling_device *cdev = NULL; - u32 capacitance = 0; if (!np) { pr_err("cpu_cooling: OF node not available for cpu%d\n", @@ -746,10 +678,9 @@ of_cpufreq_cooling_register(struct cpufreq_policy *policy) } if (of_find_property(np, "#cooling-cells", NULL)) { - of_property_read_u32(np, "dynamic-power-coefficient", - &capacitance); + struct em_perf_domain *em = em_cpu_get(policy->cpu); - cdev = __cpufreq_cooling_register(np, policy, capacitance); + cdev = __cpufreq_cooling_register(np, policy, em); if (IS_ERR(cdev)) { pr_err("cpu_cooling: cpu%d failed to register as cooling device: %ld\n", policy->cpu, PTR_ERR(cdev)); @@ -791,7 +722,6 @@ void cpufreq_cooling_unregister(struct thermal_cooling_device *cdev) thermal_cooling_device_unregister(cdev); ida_simple_remove(&cpufreq_ida, cpufreq_cdev->id); kfree(cpufreq_cdev->idle_time); - kfree(cpufreq_cdev->freq_table); kfree(cpufreq_cdev); } EXPORT_SYMBOL_GPL(cpufreq_cooling_unregister);