diff mbox series

[v5,5/7] arm64: dts: amlogic: g12a: add missing cooling info

Message ID 20190927124750.12467-7-glaroque@baylibre.com (mailing list archive)
State New, archived
Headers show
Series None | expand

Commit Message

Guillaume LA ROQUE Sept. 27, 2019, 12:47 p.m. UTC
Add missing #colling-cells field for G12A SoC
Add cooling-map for passive and hot trip point

Tested-by: Christian Hewitt <christianshewitt@gmail.com>
Tested-by: Kevin Hilman <khilman@baylibre.com>
Signed-off-by: Guillaume La Roque <glaroque@baylibre.com>
---
 arch/arm64/boot/dts/amlogic/meson-g12a.dtsi | 24 +++++++++++++++++++++
 1 file changed, 24 insertions(+)
diff mbox series

Patch

diff --git a/arch/arm64/boot/dts/amlogic/meson-g12a.dtsi b/arch/arm64/boot/dts/amlogic/meson-g12a.dtsi
index 733a9d46fc4b..3ab6497548ca 100644
--- a/arch/arm64/boot/dts/amlogic/meson-g12a.dtsi
+++ b/arch/arm64/boot/dts/amlogic/meson-g12a.dtsi
@@ -18,6 +18,7 @@ 
 			reg = <0x0 0x0>;
 			enable-method = "psci";
 			next-level-cache = <&l2>;
+			#cooling-cells = <2>;
 		};
 
 		cpu1: cpu@1 {
@@ -26,6 +27,7 @@ 
 			reg = <0x0 0x1>;
 			enable-method = "psci";
 			next-level-cache = <&l2>;
+			#cooling-cells = <2>;
 		};
 
 		cpu2: cpu@2 {
@@ -34,6 +36,7 @@ 
 			reg = <0x0 0x2>;
 			enable-method = "psci";
 			next-level-cache = <&l2>;
+			#cooling-cells = <2>;
 		};
 
 		cpu3: cpu@3 {
@@ -42,6 +45,7 @@ 
 			reg = <0x0 0x3>;
 			enable-method = "psci";
 			next-level-cache = <&l2>;
+			#cooling-cells = <2>;
 		};
 
 		l2: l2-cache0 {
@@ -113,3 +117,23 @@ 
 &sd_emmc_a {
 	amlogic,dram-access-quirk;
 };
+
+&cpu_thermal {
+	cooling-maps {
+		map0 {
+			trip = <&cpu_passive>;
+			cooling-device = <&cpu0 THERMAL_NO_LIMIT THERMAL_NO_LIMIT>,
+					<&cpu1 THERMAL_NO_LIMIT THERMAL_NO_LIMIT>,
+					<&cpu2 THERMAL_NO_LIMIT THERMAL_NO_LIMIT>,
+					<&cpu3 THERMAL_NO_LIMIT THERMAL_NO_LIMIT>;
+		};
+
+		map1 {
+			trip = <&cpu_hot>;
+			cooling-device = <&cpu0 THERMAL_NO_LIMIT THERMAL_NO_LIMIT>,
+					<&cpu1 THERMAL_NO_LIMIT THERMAL_NO_LIMIT>,
+					<&cpu2 THERMAL_NO_LIMIT THERMAL_NO_LIMIT>,
+					<&cpu3 THERMAL_NO_LIMIT THERMAL_NO_LIMIT>;
+		};
+	};
+};