@@ -2063,7 +2063,7 @@ static struct clk_regmap meson8b_vpu_0 = {
&meson8b_vpu_0_div.hw
},
.num_parents = 1,
- .flags = CLK_SET_RATE_PARENT,
+ .flags = CLK_SET_RATE_GATE | CLK_SET_RATE_PARENT,
},
};
@@ -2134,10 +2134,18 @@ static struct clk_regmap meson8b_vpu_1 = {
&meson8b_vpu_1_div.hw
},
.num_parents = 1,
- .flags = CLK_SET_RATE_PARENT,
+ .flags = CLK_SET_RATE_GATE | CLK_SET_RATE_PARENT,
},
};
+/*
+ * The VPU clock has two two identical clock trees (vpu_0 and vpu_1)
+ * muxed by a glitch-free switch on Meson8b and Meson8m2. The CCF can
+ * actually manage this glitch-free mux because it does top-to-bottom
+ * updates the each clock tree and switches to the "inactive" one when
+ * CLK_SET_RATE_GATE is set.
+ * Meson8 only has vpu_0 and no glitch-free mux.
+ */
static struct clk_regmap meson8b_vpu = {
.data = &(struct clk_regmap_mux_data){
.offset = HHI_VPU_CLK_CNTL,
@@ -2152,7 +2160,7 @@ static struct clk_regmap meson8b_vpu = {
&meson8b_vpu_1.hw,
},
.num_parents = 2,
- .flags = CLK_SET_RATE_NO_REPARENT,
+ .flags = CLK_SET_RATE_PARENT,
},
};
The "vpu_0" or "vpu_1" clock trees should not be updated while the clock is running. Enforce this by setting CLK_SET_RATE_GATE on the "vpu_0" and "vpu_1" gates. This makes the CCF switch to the "vpu_1" tree when "vpu_0" is currently active and vice versa, which is exactly what the vendor driver does when updating the frequency of the VPU clock. Signed-off-by: Martin Blumenstingl <martin.blumenstingl@googlemail.com> --- drivers/clk/meson/meson8b.c | 14 +++++++++++--- 1 file changed, 11 insertions(+), 3 deletions(-)