On Thu, Jul 14, 2022 at 05:23:44PM +0300, Paul Fertser wrote: > The old value allows measuring fan speeds down to about 970 RPM and > gives timeout for anything less than that. It is problematic because it > can also be used as an indicator for fan failure or absence. > > Despite having read the relevant section of "ASPEED AST2500/AST2520 A2 > Datasheet – V1.7" multiple times I wasn't able to figure out what > exactly "fan tach period" and "fan tach falling point of period" mean > (both are set by the driver from the constant this patch is amending). > > Experimentation with a Tioga Pass OCP board (AST2500 BMC) showed that > value of 0x0108 gives time outs for speeds below 1500 RPM and the value > offered by the patch is good for at least 750 RPM (the fans can't spin > any slower so the lower bound is unknown). Measuring with the fans > spinning takes about 30 ms, sometimes down to 18 ms, so about the same > as with the previous value. > > This constant was last changed in > 762b1e88801357770889d013c5d20fe110d1f456. > > Signed-off-by: Paul Fertser <fercerpav@gmail.com> Patrick - any feedback ? Would it be possible to test this change with Quanta-q71l ? Or do you envision no problems ? Thanks, Guenter > --- > drivers/hwmon/aspeed-pwm-tacho.c | 2 +- > 1 file changed, 1 insertion(+), 1 deletion(-) > > diff --git a/drivers/hwmon/aspeed-pwm-tacho.c b/drivers/hwmon/aspeed-pwm-tacho.c > index 3cb88d6fbec0..d11f674e3dc3 100644 > --- a/drivers/hwmon/aspeed-pwm-tacho.c > +++ b/drivers/hwmon/aspeed-pwm-tacho.c > @@ -159,7 +159,7 @@ > * 11: reserved. > */ > #define M_TACH_MODE 0x02 /* 10b */ > -#define M_TACH_UNIT 0x0210 > +#define M_TACH_UNIT 0x0420 > #define INIT_FAN_CTRL 0xFF > > /* How long we sleep in us while waiting for an RPM result. */
On Thu, Jul 14, 2022 at 05:23:44PM +0300, Paul Fertser wrote: > The old value allows measuring fan speeds down to about 970 RPM and > gives timeout for anything less than that. It is problematic because it > can also be used as an indicator for fan failure or absence. > > Despite having read the relevant section of "ASPEED AST2500/AST2520 A2 > Datasheet – V1.7" multiple times I wasn't able to figure out what > exactly "fan tach period" and "fan tach falling point of period" mean > (both are set by the driver from the constant this patch is amending). > > Experimentation with a Tioga Pass OCP board (AST2500 BMC) showed that > value of 0x0108 gives time outs for speeds below 1500 RPM and the value > offered by the patch is good for at least 750 RPM (the fans can't spin > any slower so the lower bound is unknown). Measuring with the fans > spinning takes about 30 ms, sometimes down to 18 ms, so about the same > as with the previous value. > > This constant was last changed in > 762b1e88801357770889d013c5d20fe110d1f456. > > Signed-off-by: Paul Fertser <fercerpav@gmail.com> I did not get any further feedback, so: Applied to linux-next. Thanks, Guenter > --- > drivers/hwmon/aspeed-pwm-tacho.c | 2 +- > 1 file changed, 1 insertion(+), 1 deletion(-) > > diff --git a/drivers/hwmon/aspeed-pwm-tacho.c b/drivers/hwmon/aspeed-pwm-tacho.c > index 3cb88d6fbec0..d11f674e3dc3 100644 > --- a/drivers/hwmon/aspeed-pwm-tacho.c > +++ b/drivers/hwmon/aspeed-pwm-tacho.c > @@ -159,7 +159,7 @@ > * 11: reserved. > */ > #define M_TACH_MODE 0x02 /* 10b */ > -#define M_TACH_UNIT 0x0210 > +#define M_TACH_UNIT 0x0420 > #define INIT_FAN_CTRL 0xFF > > /* How long we sleep in us while waiting for an RPM result. */
diff --git a/drivers/hwmon/aspeed-pwm-tacho.c b/drivers/hwmon/aspeed-pwm-tacho.c index 3cb88d6fbec0..d11f674e3dc3 100644 --- a/drivers/hwmon/aspeed-pwm-tacho.c +++ b/drivers/hwmon/aspeed-pwm-tacho.c @@ -159,7 +159,7 @@ * 11: reserved. */ #define M_TACH_MODE 0x02 /* 10b */ -#define M_TACH_UNIT 0x0210 +#define M_TACH_UNIT 0x0420 #define INIT_FAN_CTRL 0xFF /* How long we sleep in us while waiting for an RPM result. */
The old value allows measuring fan speeds down to about 970 RPM and gives timeout for anything less than that. It is problematic because it can also be used as an indicator for fan failure or absence. Despite having read the relevant section of "ASPEED AST2500/AST2520 A2 Datasheet – V1.7" multiple times I wasn't able to figure out what exactly "fan tach period" and "fan tach falling point of period" mean (both are set by the driver from the constant this patch is amending). Experimentation with a Tioga Pass OCP board (AST2500 BMC) showed that value of 0x0108 gives time outs for speeds below 1500 RPM and the value offered by the patch is good for at least 750 RPM (the fans can't spin any slower so the lower bound is unknown). Measuring with the fans spinning takes about 30 ms, sometimes down to 18 ms, so about the same as with the previous value. This constant was last changed in 762b1e88801357770889d013c5d20fe110d1f456. Signed-off-by: Paul Fertser <fercerpav@gmail.com> --- drivers/hwmon/aspeed-pwm-tacho.c | 2 +- 1 file changed, 1 insertion(+), 1 deletion(-)