Each CPU can (and does) participate in cooling down the system but the
DT only captures a handful of them, normally CPU0, in the cooling maps.
Things work by chance currently as under normal circumstances its the
first CPU of each cluster which is used by the operating systems to
probe the cooling devices. But as soon as this CPU ordering changes and
any other CPU is used to bring up the cooling device, we will start
seeing failures.

Also the DT is rather incomplete when we list only one CPU in the
cooling maps, as the hardware doesn't have any such limitations.

Update cooling maps to include all devices affected by individual trip
points.

Signed-off-by: Viresh Kumar <viresh.kumar@linaro.org>
---
 arch/arm64/boot/dts/socionext/uniphier-ld20.dtsi | 11 ++++-------
 1 file changed, 4 insertions(+), 7 deletions(-)

Comments

Masahiro Yamada Nov. 26, 2018, 3:49 p.m. UTC | #1
On Fri, Nov 16, 2018 at 7:06 PM Viresh Kumar <viresh.kumar@linaro.org> wrote:
>
> Each CPU can (and does) participate in cooling down the system but the
> DT only captures a handful of them, normally CPU0, in the cooling maps.
> Things work by chance currently as under normal circumstances its the
> first CPU of each cluster which is used by the operating systems to
> probe the cooling devices. But as soon as this CPU ordering changes and
> any other CPU is used to bring up the cooling device, we will start
> seeing failures.
>
> Also the DT is rather incomplete when we list only one CPU in the
> cooling maps, as the hardware doesn't have any such limitations.
>
> Update cooling maps to include all devices affected by individual trip
> points.
>
> Signed-off-by: Viresh Kumar <viresh.kumar@linaro.org>


Applied to linux-uniphier.
Thanks.




> ---
>  arch/arm64/boot/dts/socionext/uniphier-ld20.dtsi | 11 ++++-------
>  1 file changed, 4 insertions(+), 7 deletions(-)
>
> diff --git a/arch/arm64/boot/dts/socionext/uniphier-ld20.dtsi b/arch/arm64/boot/dts/socionext/uniphier-ld20.dtsi
> index d7e2d8969601..4a0c46cb11cd 100644
> --- a/arch/arm64/boot/dts/socionext/uniphier-ld20.dtsi
> +++ b/arch/arm64/boot/dts/socionext/uniphier-ld20.dtsi
> @@ -206,13 +206,10 @@
>                         cooling-maps {
>                                 map0 {
>                                         trip = <&cpu_alert>;
> -                                       cooling-device = <&cpu0
> -                                           THERMAL_NO_LIMIT THERMAL_NO_LIMIT>;
> -                               };
> -                               map1 {
> -                                       trip = <&cpu_alert>;
> -                                       cooling-device = <&cpu2
> -                                           THERMAL_NO_LIMIT THERMAL_NO_LIMIT>;
> +                                       cooling-device = <&cpu0 THERMAL_NO_LIMIT THERMAL_NO_LIMIT>,
> +                                                        <&cpu1 THERMAL_NO_LIMIT THERMAL_NO_LIMIT>,
> +                                                        <&cpu2 THERMAL_NO_LIMIT THERMAL_NO_LIMIT>,
> +                                                        <&cpu3 THERMAL_NO_LIMIT THERMAL_NO_LIMIT>;
>                                 };
>                         };
>                 };
> --
> 2.19.1.568.g152ad8e3369a
>
diff mbox series

Patch

diff --git a/arch/arm64/boot/dts/socionext/uniphier-ld20.dtsi b/arch/arm64/boot/dts/socionext/uniphier-ld20.dtsi
index d7e2d8969601..4a0c46cb11cd 100644
--- a/arch/arm64/boot/dts/socionext/uniphier-ld20.dtsi
+++ b/arch/arm64/boot/dts/socionext/uniphier-ld20.dtsi
@@ -206,13 +206,10 @@ 
 			cooling-maps {
 				map0 {
 					trip = <&cpu_alert>;
-					cooling-device = <&cpu0
-					    THERMAL_NO_LIMIT THERMAL_NO_LIMIT>;
-				};
-				map1 {
-					trip = <&cpu_alert>;
-					cooling-device = <&cpu2
-					    THERMAL_NO_LIMIT THERMAL_NO_LIMIT>;
+					cooling-device = <&cpu0 THERMAL_NO_LIMIT THERMAL_NO_LIMIT>,
+							 <&cpu1 THERMAL_NO_LIMIT THERMAL_NO_LIMIT>,
+							 <&cpu2 THERMAL_NO_LIMIT THERMAL_NO_LIMIT>,