diff mbox

[2/3] dt-bindings: power: supply: qcom_bms: Add bindings

Message ID 20180407134712.23131-2-ctatlor97@gmail.com (mailing list archive)
State Not Applicable, archived
Headers show

Commit Message

Craig Tatlor April 7, 2018, 1:46 p.m. UTC
Add bindings for the Qualcomm battery measurement system.

Signed-off-by: Craig Tatlor <ctatlor97@gmail.com>
---
 .../bindings/power/supply/qcom_bms.txt        | 93 +++++++++++++++++++
 1 file changed, 93 insertions(+)
 create mode 100644 Documentation/devicetree/bindings/power/supply/qcom_bms.txt

Comments

Linus Walleij April 26, 2018, 11:39 a.m. UTC | #1
On Sat, Apr 7, 2018 at 3:46 PM, Craig Tatlor <ctatlor97@gmail.com> wrote:

This is very interesting bindings!

> Add bindings for the Qualcomm battery measurement system.
>
> Signed-off-by: Craig Tatlor <ctatlor97@gmail.com>

Please expand on acronyms as requested by Rob.

> +Required properties:
> +- compatible:               Should contain "qcom,pm8941-bms".
> +- reg:                      Specifies the SPMI address and length of the
> +                           controller's registers.
> +- interrupts:               OCV threshold interrupt.
> +- io-channels:              Should contain IIO channel specifier for the
> +                           ADC channel that reports battery temperature.
> +- io-channel-names:         Should contain "temp".

These are fine (and good) as bindings go.

> +- qcom,fcc-temp-legend:     An array containing the temperature, in degC,
> +                           for each column of the FCC lookup table.
> +- qcom,fcc-lut:             An array of FCC values in mah, one entry for each
> +                           temperature defined in in qcom,fcc-temp-legend.
> +- qcom,ocv-temp-legend:     An array containing the temperature, in degC,
> +                           for each column of the OCV lookup table.
> +- qcom,ocv-capacity-legend: An array containing the capacity for each
> +                           row of the OCV lookup table.
> +- qcom,ocv-lut:             An array of OCV values in mV, one entry for each
> +                           capacity defined in qcom,ocv-capacity-legend.

I wonder if these are really Qualcomm-specific.

Can't we just cut the "qcom,*" prefix from all and simply define
these lookup tables in a way (with units) that makes sense to all
kinds of battery capacities?

Maybe spell them out though and avoid the abbreviations.

Just put those in the already existing
Documentation/devicetree/bindings/power/supply/battery.txt
so others can reuse them from there.

You will see that those bindings does not abbreviate but
spells out the natural sciences definitions to it's a bliss to
read for everyone.

Yours,
Linus Walleij
--
To unsubscribe from this list: send the line "unsubscribe linux-arm-msm" in
the body of a message to majordomo@vger.kernel.org
More majordomo info at  http://vger.kernel.org/majordomo-info.html
diff mbox

Patch

diff --git a/Documentation/devicetree/bindings/power/supply/qcom_bms.txt b/Documentation/devicetree/bindings/power/supply/qcom_bms.txt
new file mode 100644
index 000000000000..6296399edc09
--- /dev/null
+++ b/Documentation/devicetree/bindings/power/supply/qcom_bms.txt
@@ -0,0 +1,93 @@ 
+Qualcomm Battery Measurement System
+
+The Qualcomm Battery Measurement System is found inside of Qualcomm PM8941
+PMICs. It provides OCV and coulomb counter registers that allow the kernel
+to infer a capacity level.
+
+Required properties:
+- compatible:               Should contain "qcom,pm8941-bms".
+- reg:                      Specifies the SPMI address and length of the
+			    controller's registers.
+- interrupts:               OCV threshold interrupt.
+- io-channels:              Should contain IIO channel specifier for the
+			    ADC channel that reports battery temperature.
+- io-channel-names:         Should contain "temp".
+- qcom,fcc-temp-legend:     An array containing the temperature, in degC,
+			    for each column of the FCC lookup table.
+- qcom,fcc-lut:             An array of FCC values in mah, one entry for each
+			    temperature defined in in qcom,fcc-temp-legend.
+- qcom,ocv-temp-legend:     An array containing the temperature, in degC,
+			    for each column of the OCV lookup table.
+- qcom,ocv-capacity-legend: An array containing the capacity for each
+			    row of the OCV lookup table.
+- qcom,ocv-lut:             An array of OCV values in mV, one entry for each
+			    capacity defined in qcom,ocv-capacity-legend.
+
+Example:
+
+		pm8941_vadc: vadc@3100 {
+			compatible = "qcom,spmi-vadc";
+			reg = <0x3100>;
+			interrupts = <0x0 0x31 0x0 IRQ_TYPE_EDGE_RISING>;
+			#address-cells = <1>;
+			#size-cells = <0>;
+			#io-channel-cells = <1>;
+
+			bat_temp {
+				reg = <VADC_LR_MUX1_BAT_THERM>;
+			};
+		};
+
+		bms@4000 {
+			compatible = "qcom,pm8941-bms";
+			reg = <0x4000>;
+			interrupts = <0x0 0x40 0x4 IRQ_TYPE_EDGE_RISING>;
+			interrupt-names = "ocv_thr";
+
+			io-channels = <&pm8941_vadc VADC_LR_MUX1_BAT_THERM>;
+			io-channel-names = "temp";
+
+			qcom,fcc-temp-legend = /bits/ 8 <(-10) 0 25 50 65>;
+			qcom,fcc-lut = /bits/ 16 <6010 6070 6680 6780 6670>;
+
+			qcom,ocv-capacity-legend = /bits/ 8 <100 95 90 85
+							     80 75 70 65
+							     60 55 50 45
+							     40 35 30 25
+							     20 15 10 9
+							     8 7 6 5 4
+							     3 2 1 0>;
+
+			qcom,ocv-temp-legend = /bits/ 8 <(-10) 0 25 50 65>;
+			qcom,ocv-lut = /bits/ 16 <4288 4288 4306 4315 4315
+						  4261 4241 4259 4266 4246
+						  4201 4181 4201 4207 4187
+						  4153 4133 4150 4155 4135
+						  4105 4085 4100 4104 4084
+						  4058 4038 4052 4058 4038
+						  4012 3992 4004 4014 3994
+						  3970 3950 3959 3971 3951
+						  3931 3911 3915 3927 3907
+						  3899 3879 3880 3884 3864
+						  3873 3853 3851 3853 3833
+						  3848 3828 3827 3829 3809
+						  3829 3809 3808 3809 3789
+						  3815 3795 3791 3791 3771
+						  3801 3781 3775 3772 3752
+						  3785 3765 3751 3746 3726
+						  3767 3747 3727 3719 3699
+						  3750 3730 3702 3692 3672
+						  3728 3708 3680 3672 3652
+						  3720 3700 3676 3665 3645
+						  3712 3692 3670 3660 3645
+						  3695 3675 3658 3648 3633
+						  3662 3647 3629 3620 3610
+						  3620 3605 3589 3580 3570
+						  3562 3552 3538 3529 3519
+						  3490 3480 3474 3470 3465
+						  3403 3398 3388 3380 3375
+						  3320 3300 3255 3221 3206
+						  3000 3000 3000 3000 3000>;
+		};
+	};
+};