On Sun, Jun 07, 2020 at 05:41:06PM +0300, Dmitry Osipenko wrote: > Document generic battery temperature properties. > > Signed-off-by: Dmitry Osipenko <digetx@gmail.com> > --- > .../devicetree/bindings/power/supply/battery.txt | 10 ++++++++++ > 1 file changed, 10 insertions(+) This is close to being converted to schema: https://lore.kernel.org/linux-pm/20200707212914.31540-1-r-rivera-matos@ti.com/ > diff --git a/Documentation/devicetree/bindings/power/supply/battery.txt b/Documentation/devicetree/bindings/power/supply/battery.txt > index 5e29595edd74..e0c35eff9d3f 100644 > --- a/Documentation/devicetree/bindings/power/supply/battery.txt > +++ b/Documentation/devicetree/bindings/power/supply/battery.txt > @@ -45,6 +45,16 @@ Optional Properties: > and corresponding battery internal resistance percent, which is used to look > up the resistance percent according to current temperature to get a accurate > batterty internal resistance in different temperatures. > + - temperature-ambient-min-alert-celsius: Alert when ambient temperature of a > + battery is lower than threshold value. > + - temperature-ambient-max-alert-celsius: Alert when ambient temperature of a > + battery is higher than threshold value. > + - temperature-min-alert-celsius: Alert when battery temperature is lower > + than threshold value. > + - temperature-max-alert-celsius: Alert when battery temperature is higher > + than threshold value. > + - temperature-min-celsius: minimum temperature at which battery can operate > + - temperature-max-celsius: maximum temperature at which battery can operate Perhaps 'temperature' is redundant since we have units. Perhaps do <min max> properties given specifying only min or max is probably not valid? Rob
14.07.2020 02:46, Rob Herring пишет: > On Sun, Jun 07, 2020 at 05:41:06PM +0300, Dmitry Osipenko wrote: >> Document generic battery temperature properties. >> >> Signed-off-by: Dmitry Osipenko <digetx@gmail.com> >> --- >> .../devicetree/bindings/power/supply/battery.txt | 10 ++++++++++ >> 1 file changed, 10 insertions(+) > > This is close to being converted to schema: > > https://lore.kernel.org/linux-pm/20200707212914.31540-1-r-rivera-matos@ti.com/ Thanks! I'll keep an eye on this patch. >> diff --git a/Documentation/devicetree/bindings/power/supply/battery.txt b/Documentation/devicetree/bindings/power/supply/battery.txt >> index 5e29595edd74..e0c35eff9d3f 100644 >> --- a/Documentation/devicetree/bindings/power/supply/battery.txt >> +++ b/Documentation/devicetree/bindings/power/supply/battery.txt >> @@ -45,6 +45,16 @@ Optional Properties: >> and corresponding battery internal resistance percent, which is used to look >> up the resistance percent according to current temperature to get a accurate >> batterty internal resistance in different temperatures. >> + - temperature-ambient-min-alert-celsius: Alert when ambient temperature of a >> + battery is lower than threshold value. >> + - temperature-ambient-max-alert-celsius: Alert when ambient temperature of a >> + battery is higher than threshold value. >> + - temperature-min-alert-celsius: Alert when battery temperature is lower >> + than threshold value. >> + - temperature-max-alert-celsius: Alert when battery temperature is higher >> + than threshold value. >> + - temperature-min-celsius: minimum temperature at which battery can operate >> + - temperature-max-celsius: maximum temperature at which battery can operate > > Perhaps 'temperature' is redundant since we have units. > > Perhaps do <min max> properties given specifying only min or max is > probably not valid? Thank you for the suggestions, I'll consider them for the v3!
diff --git a/Documentation/devicetree/bindings/power/supply/battery.txt b/Documentation/devicetree/bindings/power/supply/battery.txt index 5e29595edd74..e0c35eff9d3f 100644 --- a/Documentation/devicetree/bindings/power/supply/battery.txt +++ b/Documentation/devicetree/bindings/power/supply/battery.txt @@ -45,6 +45,16 @@ Optional Properties: and corresponding battery internal resistance percent, which is used to look up the resistance percent according to current temperature to get a accurate batterty internal resistance in different temperatures. + - temperature-ambient-min-alert-celsius: Alert when ambient temperature of a + battery is lower than threshold value. + - temperature-ambient-max-alert-celsius: Alert when ambient temperature of a + battery is higher than threshold value. + - temperature-min-alert-celsius: Alert when battery temperature is lower + than threshold value. + - temperature-max-alert-celsius: Alert when battery temperature is higher + than threshold value. + - temperature-min-celsius: minimum temperature at which battery can operate + - temperature-max-celsius: maximum temperature at which battery can operate Battery properties are named, where possible, for the corresponding elements in enum power_supply_property, defined in
Document generic battery temperature properties. Signed-off-by: Dmitry Osipenko <digetx@gmail.com> --- .../devicetree/bindings/power/supply/battery.txt | 10 ++++++++++ 1 file changed, 10 insertions(+)