@@ -117,6 +117,88 @@ properties:
description: Enable over current protection.
type: boolean
+ regulator-oc-protection-microamp:
+ description: Set over current protection limit. This is a limit where
+ hardware performs emergency shutdown. Zero can be passed to disable
+ protection and value '1' indicates that protection should be enabled but
+ limit setting can be omitted.
+
+ regulator-oc-error-microamp:
+ description: Set over current error limit. This is a limit where part of
+ the hardware propably is malfunctional and damage prevention is requested.
+ Zero can be passed to disable error detection and value '1' indicates
+ that detection should be enabled but limit setting can be omitted.
+
+ regulator-oc-warn-microamp:
+ description: Set over current warning limit. This is a limit where hardware
+ is assumed still to be functional but approaching limit where it gets
+ damaged. Recovery actions should be initiated. Zero can be passed to
+ disable detection and value '1' indicates that detection should
+ be enabled but limit setting can be omitted.
+
+ regulator-ov-protection-microvolt:
+ description: Set over voltage protection limit. This is a limit where
+ hardware performs emergency shutdown. Zero can be passed to disable
+ protection and value '1' indicates that protection should be enabled but
+ limit setting can be omitted. Limit is given as microvolt offset from
+ voltage set to regulator.
+
+ regulator-ov-error-microvolt:
+ description: Set over voltage error limit. This is a limit where part of
+ the hardware propably is malfunctional and damage prevention is requested
+ Zero can be passed to disable error detection and value '1' indicates
+ that detection should be enabled but limit setting can be omitted. Limit
+ is given as microvolt offset from voltage set to regulator.
+
+ regulator-ov-warn-microvolt:
+ description: Set over voltage warning limit. This is a limit where hardware
+ is assumed still to be functional but approaching limit where it gets
+ damaged. Recovery actions should be initiated. Zero can be passed to
+ disable detection and value '1' indicates that detection should
+ be enabled but limit setting can be omitted. Limit is given as microvolt
+ offset from voltage set to regulator.
+
+ regulator-uv-protection-microvolt:
+ description: Set over under voltage protection limit. This is a limit where
+ hardware performs emergency shutdown. Zero can be passed to disable
+ protection and value '1' indicates that protection should be enabled but
+ limit setting can be omitted. Limit is given as microvolt offset from
+ voltage set to regulator.
+
+ regulator-uv-error-microvolt:
+ description: Set under voltage error limit. This is a limit where part of
+ the hardware propably is malfunctional and damage prevention is requested
+ Zero can be passed to disable error detection and value '1' indicates
+ that detection should be enabled but limit setting can be omitted. Limit
+ is given as microvolt offset from voltage set to regulator.
+
+ regulator-uv-warn-microvolt:
+ description: Set over under voltage warning limit. This is a limit where
+ hardware is assumed still to be functional but approaching limit where
+ it gets damaged. Recovery actions should be initiated. Zero can be passed
+ to disable detection and value '1' indicates that detection should
+ be enabled but limit setting can be omitted. Limit is given as microvolt
+ offset from voltage set to regulator.
+
+ regulator-temp-protection-kelvin:
+ description: Set over temperature protection limit. This is a limit where
+ hardware performs emergency shutdown. Zero can be passed to disable
+ protection and value '1' indicates that protection should be enabled but
+ limit setting can be omitted.
+
+ regulator-temp-error-kelvin:
+ description: Set over temperature error limit. This is a limit where part of
+ the hardware propably is malfunctional and damage prevention is requested
+ Zero can be passed to disable error detection and value '1' indicates
+ that detection should be enabled but limit setting can be omitted.
+
+ regulator-temp-warn-kelvin:
+ description: Set over temperature warning limit. This is a limit where
+ hardware is assumed still to be functional but approaching limit where it
+ gets damaged. Recovery actions should be initiated. Zero can be passed to
+ disable detection and value '1' indicates that detection should
+ be enabled but limit setting can be omitted.
+
regulator-active-discharge:
description: |
tristate, enable/disable active discharge of regulators. The values are: