@@ -2718,6 +2718,15 @@ static int __init xlblk_init(void)
if (!xen_domain())
return -ENODEV;
+ if (!xen_has_pv_disk_devices())
+ return -ENODEV;
+
+ if (register_blkdev(XENVBD_MAJOR, DEV_NAME)) {
+ pr_warn("xen_blk: can't get major %d with name %s\n",
+ XENVBD_MAJOR, DEV_NAME);
+ return -ENODEV;
+ }
+
if (xen_blkif_max_segments < BLKIF_MAX_SEGMENTS_PER_REQUEST)
xen_blkif_max_segments = BLKIF_MAX_SEGMENTS_PER_REQUEST;
@@ -2733,15 +2742,6 @@ static int __init xlblk_init(void)
xen_blkif_max_queues = nr_cpus;
}
- if (!xen_has_pv_disk_devices())
- return -ENODEV;
-
- if (register_blkdev(XENVBD_MAJOR, DEV_NAME)) {
- printk(KERN_WARNING "xen_blk: can't get major %d with name %s\n",
- XENVBD_MAJOR, DEV_NAME);
- return -ENODEV;
- }
-
INIT_DELAYED_WORK(&blkfront_work, blkfront_delay_work);
ret = xenbus_register_frontend(&blkfront_driver);
In case we don't want pv block devices we should not test parameters for sanity and eventually print out error messages. So test precluding conditions before checking parameters. Signed-off-by: Juergen Gross <jgross@suse.com> --- drivers/block/xen-blkfront.c | 18 +++++++++--------- 1 file changed, 9 insertions(+), 9 deletions(-)