Message ID | 20190402210623.14988-3-jernej.skrabec@siol.net (mailing list archive) |
---|---|
State | Awaiting Upstream, archived |
Headers | show |
Series | clk: sunxi-ng: H6 related clock fixes | expand |
On Tue, Apr 02, 2019 at 11:06:22PM +0200, Jernej Skrabec wrote: > H6 manual and BSP clock driver both states that hdmi-cec clock has two > possible parents, osc32k and pll-periph0-2x with 36621 predivider. > Because pll-periph0-2x is always 1.2 GHz, both parents give same > hdmi-cec rate - 32768 Hz, which is exactly the rate needed for HDMI CEC > controller to operate correctly. > > However, for some reason, HDMI CEC controller doesn't work if default > parent (osc32k) is used. BSP HDMI driver also always use pll-periph0-2x > as hdmi-cec clock parent. > > In order to solve the issue, preset hdmi-cec clock parent to > pll-periph0-2x. > > Signed-off-by: Jernej Skrabec <jernej.skrabec@siol.net> Applied, thanks! Maxime -- Maxime Ripard, Bootlin Embedded Linux and Kernel engineering https://bootlin.com
diff --git a/drivers/clk/sunxi-ng/ccu-sun50i-h6.c b/drivers/clk/sunxi-ng/ccu-sun50i-h6.c index daf78966555e..33980067b06e 100644 --- a/drivers/clk/sunxi-ng/ccu-sun50i-h6.c +++ b/drivers/clk/sunxi-ng/ccu-sun50i-h6.c @@ -656,6 +656,8 @@ static const char * const hdmi_cec_parents[] = { "osc32k", "pll-periph0-2x" }; static const struct ccu_mux_fixed_prediv hdmi_cec_predivs[] = { { .index = 1, .div = 36621 }, }; + +#define SUN50I_H6_HDMI_CEC_CLK_REG 0xb10 static struct ccu_mux hdmi_cec_clk = { .enable = BIT(31), @@ -1200,6 +1202,15 @@ static int sun50i_h6_ccu_probe(struct platform_device *pdev) val &= ~(GENMASK(21, 16) | BIT(0)); writel(val | (7 << 16), reg + SUN50I_H6_PLL_AUDIO_REG); + /* + * First clock parent (osc32K) is unusable for CEC. But since there + * is no good way to force parent switch (both run with same frequency), + * just set second clock parent here. + */ + val = readl(reg + SUN50I_H6_HDMI_CEC_CLK_REG); + val |= BIT(24); + writel(val, reg + SUN50I_H6_HDMI_CEC_CLK_REG); + return sunxi_ccu_probe(pdev->dev.of_node, reg, &sun50i_h6_ccu_desc); }
H6 manual and BSP clock driver both states that hdmi-cec clock has two possible parents, osc32k and pll-periph0-2x with 36621 predivider. Because pll-periph0-2x is always 1.2 GHz, both parents give same hdmi-cec rate - 32768 Hz, which is exactly the rate needed for HDMI CEC controller to operate correctly. However, for some reason, HDMI CEC controller doesn't work if default parent (osc32k) is used. BSP HDMI driver also always use pll-periph0-2x as hdmi-cec clock parent. In order to solve the issue, preset hdmi-cec clock parent to pll-periph0-2x. Signed-off-by: Jernej Skrabec <jernej.skrabec@siol.net> --- drivers/clk/sunxi-ng/ccu-sun50i-h6.c | 11 +++++++++++ 1 file changed, 11 insertions(+)