@@ -943,7 +943,6 @@ static int sun50i_a64_ccu_probe(struct platform_device *pdev)
struct resource *res;
void __iomem *reg;
u32 val;
- int ret;
res = platform_get_resource(pdev, IORESOURCE_MEM, 0);
reg = devm_ioremap_resource(&pdev->dev, res);
@@ -1029,18 +1028,7 @@ static int sun50i_a64_ccu_probe(struct platform_device *pdev)
writel(val, reg + SUN50I_A64_CPUX_AXI_REG);
}
- ret = sunxi_ccu_probe(pdev->dev.of_node, reg, &sun50i_a64_ccu_desc);
- if (ret)
- return ret;
-
- /* Gate then ungate PLL CPU after any rate changes */
- ccu_pll_notifier_register(&sun50i_a64_pll_cpu_nb);
-
- /* Reparent CPU during PLL CPU rate changes */
- ccu_mux_notifier_register(pll_cpux_clk.common.hw.clk,
- &sun50i_a64_cpu_nb);
-
- return 0;
+ return sunxi_ccu_probe(pdev->dev.of_node, reg, &sun50i_a64_ccu_desc);
}
static const struct of_device_id sun50i_a64_ccu_ids[] = {
After the dividers of PLL-CPUX disabled, there's no need for PLL-CPUX to be gated when tweaking the clock of CPUX, thus reparenting CPUX to osc24M is also now not needed. Remove these notifiers. Preventing reparenting CPUX is said to be able to help solving the issue that the timer jumps backward according to Ondrej Jirman. Signed-off-by: Icenowy Zheng <icenowy@aosc.io> --- drivers/clk/sunxi-ng/ccu-sun50i-a64.c | 14 +------------- 1 file changed, 1 insertion(+), 13 deletions(-)