@@ -1,4 +1,5 @@
// SPDX-License-Identifier: GPL-2.0
+#include <dt-bindings/clock/mediatek,mtmips-sysc.h>
/ {
#address-cells = <1>;
@@ -16,11 +17,6 @@ cpu@0 {
};
};
- resetc: reset-controller {
- compatible = "ralink,rt2880-reset";
- #reset-cells = <1>;
- };
-
cpuintc: interrupt-controller {
#address-cells = <0>;
#interrupt-cells = <1>;
@@ -36,9 +32,11 @@ palmbus@10000000 {
#address-cells = <1>;
#size-cells = <1>;
- sysc: system-controller@0 {
- compatible = "ralink,mt7620a-sysc", "syscon";
+ sysc: syscon@0 {
+ compatible = "ralink,mt7628-sysc", "syscon";
reg = <0x0 0x60>;
+ #clock-cells = <1>;
+ #reset-cells = <1>;
};
pinmux: pinmux@60 {
@@ -138,7 +136,7 @@ watchdog: watchdog@100 {
compatible = "mediatek,mt7621-wdt";
reg = <0x100 0x30>;
- resets = <&resetc 8>;
+ resets = <&sysc 8>;
reset-names = "wdt";
interrupt-parent = <&intc>;
@@ -154,7 +152,7 @@ intc: interrupt-controller@200 {
interrupt-controller;
#interrupt-cells = <1>;
- resets = <&resetc 9>;
+ resets = <&sysc 9>;
reset-names = "intc";
interrupt-parent = <&cpuintc>;
@@ -190,7 +188,9 @@ spi: spi@b00 {
pinctrl-names = "default";
pinctrl-0 = <&pinmux_spi_spi>;
- resets = <&resetc 18>;
+ clocks = <&sysc MT76X8_CLK_SPI1>;
+
+ resets = <&sysc 18>;
reset-names = "spi";
#address-cells = <1>;
@@ -206,7 +206,9 @@ i2c: i2c@900 {
pinctrl-names = "default";
pinctrl-0 = <&pinmux_i2c_i2c>;
- resets = <&resetc 16>;
+ clocks = <&sysc MT76X8_CLK_I2C>;
+
+ resets = <&sysc 16>;
reset-names = "i2c";
#address-cells = <1>;
@@ -222,7 +224,9 @@ uart0: uartlite@c00 {
pinctrl-names = "default";
pinctrl-0 = <&pinmux_uart0_uart>;
- resets = <&resetc 12>;
+ clocks = <&sysc MT76X8_CLK_UART0>;
+
+ resets = <&sysc 12>;
reset-names = "uart0";
interrupt-parent = <&intc>;
@@ -238,7 +242,9 @@ uart1: uart1@d00 {
pinctrl-names = "default";
pinctrl-0 = <&pinmux_uart1_uart>;
- resets = <&resetc 19>;
+ clocks = <&sysc MT76X8_CLK_UART1>;
+
+ resets = <&sysc 19>;
reset-names = "uart1";
interrupt-parent = <&intc>;
@@ -254,7 +260,9 @@ uart2: uart2@e00 {
pinctrl-names = "default";
pinctrl-0 = <&pinmux_uart2_uart>;
- resets = <&resetc 20>;
+ clocks = <&sysc MT76X8_CLK_UART2>;
+
+ resets = <&sysc 20>;
reset-names = "uart2";
interrupt-parent = <&intc>;
@@ -290,6 +298,8 @@ wmac: wmac@10300000 {
compatible = "mediatek,mt7628-wmac";
reg = <0x10300000 0x100000>;
+ clocks = <&sysc MT76X8_CLK_WMAC>;
+
interrupt-parent = <&cpuintc>;
interrupts = <6>;
Current MT7628A device tree file system controller node is wrong since it is not matching bindings. Hence, update it to match current bindings updating it also to use new introduced clock constants. Signed-off-by: Sergio Paracuellos <sergio.paracuellos@gmail.com> --- arch/mips/boot/dts/ralink/mt7628a.dtsi | 38 ++++++++++++++++---------- 1 file changed, 24 insertions(+), 14 deletions(-)