diff mbox series

[v3] fpga: dfl: fme: Fix cpu hotplug issue in performance reporting

Message ID 20210713074216.208391-1-kjain@linux.ibm.com (mailing list archive)
State New
Headers show
Series [v3] fpga: dfl: fme: Fix cpu hotplug issue in performance reporting | expand

Commit Message

kajoljain July 13, 2021, 7:42 a.m. UTC
The performance reporting driver added cpu hotplug
feature but it didn't add pmu migration call in cpu
offline function.
This can create an issue incase the current designated
cpu being used to collect fme pmu data got offline,
as based on current code we are not migrating fme pmu to
new target cpu. Because of that perf will still try to
fetch data from that offline cpu and hence we will not
get counter data.

Patch fixed this issue by adding pmu_migrate_context call
in fme_perf_offline_cpu function.

Fixes: 724142f8c42a ("fpga: dfl: fme: add performance reporting support")
Tested-by: Xu Yilun <yilun.xu@intel.com>
Acked-by: Wu Hao <hao.wu@intel.com>
Signed-off-by: Kajol Jain <kjain@linux.ibm.com>
Cc: stable@vger.kernel.org
---
 drivers/fpga/dfl-fme-perf.c | 2 ++
 1 file changed, 2 insertions(+)

---
Changelog:
v2 -> v3:
- Added Acked-by tag
- Removed comment as suggested by Wu Hao
- Link to patch v2: https://lkml.org/lkml/2021/7/9/143

v1 -> v2:
- Add stable@vger.kernel.org in cc list
- Link to patch v1: https://lkml.org/lkml/2021/6/28/275

RFC -> PATCH v1
- Remove RFC tag
- Did nits changes on subject and commit message as suggested by Xu Yilun
- Added Tested-by tag
- Link to rfc patch: https://lkml.org/lkml/2021/6/28/112
---

Comments

kajoljain Aug. 2, 2021, 7:45 a.m. UTC | #1
On 7/13/21 1:12 PM, Kajol Jain wrote:
> The performance reporting driver added cpu hotplug
> feature but it didn't add pmu migration call in cpu
> offline function.
> This can create an issue incase the current designated
> cpu being used to collect fme pmu data got offline,
> as based on current code we are not migrating fme pmu to
> new target cpu. Because of that perf will still try to
> fetch data from that offline cpu and hence we will not
> get counter data.
> 
> Patch fixed this issue by adding pmu_migrate_context call
> in fme_perf_offline_cpu function.
> 
> Fixes: 724142f8c42a ("fpga: dfl: fme: add performance reporting support")
> Tested-by: Xu Yilun <yilun.xu@intel.com>
> Acked-by: Wu Hao <hao.wu@intel.com>
> Signed-off-by: Kajol Jain <kjain@linux.ibm.com>
> Cc: stable@vger.kernel.org
> ---

Any update on this patch? Please let me know if any changes required.

Thanks,
Kajol Jain

>  drivers/fpga/dfl-fme-perf.c | 2 ++
>  1 file changed, 2 insertions(+)
> 
> ---
> Changelog:
> v2 -> v3:
> - Added Acked-by tag
> - Removed comment as suggested by Wu Hao
> - Link to patch v2: https://lkml.org/lkml/2021/7/9/143
> 
> v1 -> v2:
> - Add stable@vger.kernel.org in cc list
> - Link to patch v1: https://lkml.org/lkml/2021/6/28/275
> 
> RFC -> PATCH v1
> - Remove RFC tag
> - Did nits changes on subject and commit message as suggested by Xu Yilun
> - Added Tested-by tag
> - Link to rfc patch: https://lkml.org/lkml/2021/6/28/112
> ---
> 
> diff --git a/drivers/fpga/dfl-fme-perf.c b/drivers/fpga/dfl-fme-perf.c
> index 4299145ef347..587c82be12f7 100644
> --- a/drivers/fpga/dfl-fme-perf.c
> +++ b/drivers/fpga/dfl-fme-perf.c
> @@ -953,6 +953,8 @@ static int fme_perf_offline_cpu(unsigned int cpu, struct hlist_node *node)
>  		return 0;
>  
>  	priv->cpu = target;
> +	perf_pmu_migrate_context(&priv->pmu, cpu, target);
> +
>  	return 0;
>  }
>  
>
Moritz Fischer Aug. 2, 2021, 8:58 a.m. UTC | #2
On Mon, Aug 02, 2021 at 01:15:00PM +0530, kajoljain wrote:
> 
> 
> On 7/13/21 1:12 PM, Kajol Jain wrote:
> > The performance reporting driver added cpu hotplug
> > feature but it didn't add pmu migration call in cpu
> > offline function.
> > This can create an issue incase the current designated
> > cpu being used to collect fme pmu data got offline,
> > as based on current code we are not migrating fme pmu to
> > new target cpu. Because of that perf will still try to
> > fetch data from that offline cpu and hence we will not
> > get counter data.
> > 
> > Patch fixed this issue by adding pmu_migrate_context call
> > in fme_perf_offline_cpu function.
> > 
> > Fixes: 724142f8c42a ("fpga: dfl: fme: add performance reporting support")
> > Tested-by: Xu Yilun <yilun.xu@intel.com>
> > Acked-by: Wu Hao <hao.wu@intel.com>
> > Signed-off-by: Kajol Jain <kjain@linux.ibm.com>
> > Cc: stable@vger.kernel.org
> > ---
> 
> Any update on this patch? Please let me know if any changes required.
> 
> Thanks,
> Kajol Jain

It's in my 'fixes' branch.

- Moritz
kajoljain Aug. 2, 2021, 11:46 a.m. UTC | #3
On 8/2/21 2:28 PM, Moritz Fischer wrote:
> On Mon, Aug 02, 2021 at 01:15:00PM +0530, kajoljain wrote:
>>
>>
>> On 7/13/21 1:12 PM, Kajol Jain wrote:
>>> The performance reporting driver added cpu hotplug
>>> feature but it didn't add pmu migration call in cpu
>>> offline function.
>>> This can create an issue incase the current designated
>>> cpu being used to collect fme pmu data got offline,
>>> as based on current code we are not migrating fme pmu to
>>> new target cpu. Because of that perf will still try to
>>> fetch data from that offline cpu and hence we will not
>>> get counter data.
>>>
>>> Patch fixed this issue by adding pmu_migrate_context call
>>> in fme_perf_offline_cpu function.
>>>
>>> Fixes: 724142f8c42a ("fpga: dfl: fme: add performance reporting support")
>>> Tested-by: Xu Yilun <yilun.xu@intel.com>
>>> Acked-by: Wu Hao <hao.wu@intel.com>
>>> Signed-off-by: Kajol Jain <kjain@linux.ibm.com>
>>> Cc: stable@vger.kernel.org
>>> ---
>>
>> Any update on this patch? Please let me know if any changes required.
>>
>> Thanks,
>> Kajol Jain
> 
> It's in my 'fixes' branch.

Thanks Moritz for informing me.

Thanks,
Kajol Jain

> 
> - Moritz
>
diff mbox series

Patch

diff --git a/drivers/fpga/dfl-fme-perf.c b/drivers/fpga/dfl-fme-perf.c
index 4299145ef347..587c82be12f7 100644
--- a/drivers/fpga/dfl-fme-perf.c
+++ b/drivers/fpga/dfl-fme-perf.c
@@ -953,6 +953,8 @@  static int fme_perf_offline_cpu(unsigned int cpu, struct hlist_node *node)
 		return 0;
 
 	priv->cpu = target;
+	perf_pmu_migrate_context(&priv->pmu, cpu, target);
+
 	return 0;
 }