[v3,2/3] hwmon: ltc2990: add devicetree binding

Message ID 1499056140-6064-2-git-send-email-tom.levens@cern.ch (mailing list archive)
State Accepted
Headers show

Commit Message

Tom Levens July 3, 2017, 4:28 a.m. UTC
Add a devicetree binding for the ltc2990 hwmon driver.

Signed-off-by: Tom Levens <tom.levens@cern.ch>
---
 .../devicetree/bindings/hwmon/ltc2990.txt          | 36 ++++++++++++++++++++++
 1 file changed, 36 insertions(+)
 create mode 100644 Documentation/devicetree/bindings/hwmon/ltc2990.txt

Comments

Rob Herring July 7, 2017, 2:24 p.m. UTC | #1
On Mon, Jul 03, 2017 at 06:28:59AM +0200, Tom Levens wrote:
> Add a devicetree binding for the ltc2990 hwmon driver.

Bindings are for a device, not a Linux driver.

> 
> Signed-off-by: Tom Levens <tom.levens@cern.ch>
> ---
>  .../devicetree/bindings/hwmon/ltc2990.txt          | 36 ++++++++++++++++++++++
>  1 file changed, 36 insertions(+)
>  create mode 100644 Documentation/devicetree/bindings/hwmon/ltc2990.txt

Otherwise,

Acked-by: Rob Herring <robh@kernel.org>
--
To unsubscribe from this list: send the line "unsubscribe linux-hwmon" in
the body of a message to majordomo@vger.kernel.org
More majordomo info at  http://vger.kernel.org/majordomo-info.html
diff mbox

Patch

diff --git a/Documentation/devicetree/bindings/hwmon/ltc2990.txt b/Documentation/devicetree/bindings/hwmon/ltc2990.txt
new file mode 100644
index 0000000..f92f540
--- /dev/null
+++ b/Documentation/devicetree/bindings/hwmon/ltc2990.txt
@@ -0,0 +1,36 @@ 
+ltc2990: Linear Technology LTC2990 power monitor
+
+Required properties:
+- compatible: Must be "lltc,ltc2990"
+- reg: I2C slave address
+- lltc,meas-mode:
+	An array of two integers for configuring the chip measurement mode.
+
+	The first integer defines the bits 2..0 in the control register. In all
+	cases the internal temperature and supply voltage are measured. In
+	addition the following input measurements are enabled per mode:
+
+		0: V1, V2, TR2
+		1: V1-V2, TR2
+		2: V1-V2, V3, V4
+		3: TR1, V3, V4
+		4: TR1, V3-V4
+		5: TR1, TR2
+		6: V1-V2, V3-V4
+		7: V1, V2, V3, V4
+
+	The second integer defines the bits 4..3 in the control register. This
+	allows a subset of the measurements to be enabled:
+
+		0: Internal temperature and supply voltage only
+		1: TR1, V1 or V1-V2 only per mode
+		2: TR2, V3 or V3-V4 only per mode
+		3: All measurements per mode
+
+Example:
+
+ltc2990@4c {
+	compatible = "lltc,ltc2990";
+	reg = <0x4c>;
+	lltc,meas-mode = <7 3>;	/* V1, V2, V3, V4 */
+};