Message ID | 20200512093806.28515-1-Amy.Shih@advantech.com.tw (mailing list archive) |
---|---|
State | Accepted |
Headers | show |
Series | [v1,1/1] hwmon: (nct7904) Fix the incorrect rang of temperature limitation registers. | expand |
diff --git a/drivers/hwmon/nct7904.c b/drivers/hwmon/nct7904.c index 6fb06f7..04f2a8e 100644 --- a/drivers/hwmon/nct7904.c +++ b/drivers/hwmon/nct7904.c @@ -390,6 +390,7 @@ static int nct7904_read_temp(struct device *dev, u32 attr, int channel, struct nct7904_data *data = dev_get_drvdata(dev); int ret, temp; unsigned int reg1, reg2, reg3; + s8 temps; switch (attr) { case hwmon_temp_input: @@ -495,7 +496,8 @@ static int nct7904_read_temp(struct device *dev, u32 attr, int channel, if (ret < 0) return ret; - *val = ret * 1000; + temps = ret; + *val = temps * 1000; return 0; }