@@ -84,6 +84,7 @@ struct acpi_power_meter_resource {
u64 power;
u64 cap;
u64 avg_interval;
+ bool power_alarm;
int sensors_valid;
unsigned long sensors_last_updated;
struct sensor_device_attribute sensors[NUM_SENSORS];
@@ -396,6 +397,9 @@ static ssize_t show_val(struct device *dev,
struct acpi_device *acpi_dev = to_acpi_device(dev);
struct acpi_power_meter_resource *resource = acpi_dev->driver_data;
u64 val = 0;
+ int ret;
+
+ guard(mutex)(&resource->lock);
switch (attr->index) {
case 0:
@@ -423,10 +427,17 @@ static ssize_t show_val(struct device *dev,
val = 0;
break;
case 6:
- if (resource->power > resource->cap)
- val = 1;
- else
- val = 0;
+ ret = update_meter(resource);
+ if (ret)
+ return ret;
+ /* need to update cap if not to support the notification. */
+ if (!(resource->caps.flags & POWER_METER_CAN_NOTIFY)) {
+ ret = update_cap(resource);
+ if (ret)
+ return ret;
+ }
+ val = resource->power_alarm || resource->power > resource->cap;
+ resource->power_alarm = resource->power > resource->cap;
break;
case 7:
case 8:
@@ -847,12 +858,20 @@ static void acpi_power_meter_notify(struct acpi_device *device, u32 event)
sysfs_notify(&device->dev.kobj, NULL, POWER_AVERAGE_NAME);
break;
case METER_NOTIFY_CAP:
+ mutex_lock(&resource->lock);
+ res = update_cap(resource);
+ if (res)
+ dev_err_once(&device->dev, "update cap failed when capping value is changed.\n");
+ mutex_unlock(&resource->lock);
sysfs_notify(&device->dev.kobj, NULL, POWER_CAP_NAME);
break;
case METER_NOTIFY_INTERVAL:
sysfs_notify(&device->dev.kobj, NULL, POWER_AVG_INTERVAL_NAME);
break;
case METER_NOTIFY_CAPPING:
+ mutex_lock(&resource->lock);
+ resource->power_alarm = true;
+ mutex_unlock(&resource->lock);
sysfs_notify(&device->dev.kobj, NULL, POWER_ALARM_NAME);
dev_info(&device->dev, "Capping in progress.\n");
break;
The 'power1_alarm' attribute uses the 'power' and 'cap' in the acpi_power_meter_resource structure. Currently, these two fields are just updated when user query 'power' and 'cap' attribute. If user directly query the 'power1_alarm' attribute without queryng above two attributes, driver will use uninitialized variables to judge. So this patch adds the setting of alarm state and update 'cap' in the notification callback and update 'power' and 'cap' if needed to show the real alarm state. Signed-off-by: Huisong Li <lihuisong@huawei.com> --- drivers/hwmon/acpi_power_meter.c | 27 +++++++++++++++++++++++---- 1 file changed, 23 insertions(+), 4 deletions(-)