diff mbox series

[v3,1/6] iio: adc: ad7124: Remove shift from scan_type

Message ID 20220322105029.86389-2-alexandru.tachici@analog.com (mailing list archive)
State Accepted
Headers show
Series iio: adc: ad_sigma_delta: Add sequencer support | expand

Commit Message

Alexandru Tachici March 22, 2022, 10:50 a.m. UTC
From: Alexandru Tachici <alexandru.tachici@analog.com>

The 24 bits data is stored in 32 bits in BE. There
is no need to shift it. This confuses user-space apps.

Fixes: b3af341bbd966 ("iio: adc: Add ad7124 support")
Signed-off-by: Alexandru Tachici <alexandru.tachici@analog.com>
---
 drivers/iio/adc/ad7124.c | 1 -
 1 file changed, 1 deletion(-)
diff mbox series

Patch

diff --git a/drivers/iio/adc/ad7124.c b/drivers/iio/adc/ad7124.c
index 998a342d51a6..7249db2c4422 100644
--- a/drivers/iio/adc/ad7124.c
+++ b/drivers/iio/adc/ad7124.c
@@ -188,7 +188,6 @@  static const struct iio_chan_spec ad7124_channel_template = {
 		.sign = 'u',
 		.realbits = 24,
 		.storagebits = 32,
-		.shift = 8,
 		.endianness = IIO_BE,
 	},
 };