Message ID | 20220808120549.1543338-1-cmo@melexis.com (mailing list archive) |
---|---|
State | Superseded |
Headers | show |
Series | iio: temperature: mlx90632: Add supply regulator | expand |
diff --git a/Documentation/devicetree/bindings/iio/temperature/melexis,mlx90632.yaml b/Documentation/devicetree/bindings/iio/temperature/melexis,mlx90632.yaml index b547ddcd544a..4a55e7f25ae7 100644 --- a/Documentation/devicetree/bindings/iio/temperature/melexis,mlx90632.yaml +++ b/Documentation/devicetree/bindings/iio/temperature/melexis,mlx90632.yaml @@ -35,6 +35,9 @@ properties: maxItems: 1 description: Default is 0x3a, but can be reprogrammed. + vdd-supply: + description: provide VDD power to the sensor. + required: - compatible - reg @@ -50,6 +53,7 @@ examples: temp-sensor@3a { compatible = "melexis,mlx90632"; reg = <0x3a>; + vdd-supply = <&ldo4_reg>; }; }; ...